Beckett CF375, CF3500A, CF800, CF2500A, CF2300A setup guide Columbia Boiler, CWH Series Boiler

Page 11

 

Columbia Boiler

 

 

CT

Series Boiler

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High

 

 

Blue -

Red -

Low Fire

 

 

 

 

 

 

 

 

 

 

 

Low Fire

High Fire

High Fire

Pressure

 

 

 

Boiler

Burner

Chassis

Air Tube

Fire

 

Head

Air or

Air or

Pump

Pump

Firing

Insertion

 

 

Spec.

Combination

Rate

Nozzle

Setting

Shutter

Band

Press.

Press.

Flange

 

 

CT-20

CF800

BCF403

CF100KJ

6.00

5.00x60P

3

7

0

N/A

150

51628

4.75"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CT-25

CF1000

BCF101

CF66KD

7.50

4.50x60P

3

5

N/A

N/A

275

51629

4.75"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CT-25

CF1400

BCF205

CF66KD

9.00

5.50x60P

3

30

50

150

300

51629

4.75"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CT-35

CF2300A

BCF304

CF66KG

10.50

6.00x45P

3

30

50

150

300

51630

4.75"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CT-50

CF2300A

BCF304

CF66KG

15.00

9.00x60P

3

30

50

150

300

51630

4.75"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.

 

Columbia Boiler

CWH Series Boiler

 

 

 

 

 

High

 

 

Blue -

Red -

Low Fire

 

 

 

 

 

 

 

 

 

 

 

Low Fire

High Fire

High Fire

Pressure

 

 

 

Boiler

Burner

Chassis

Air Tube

Fire

 

Head

Air or

Air or

Pump

Pump

Firing

Insertion

 

 

Spec.

Combination

Rate

Nozzle

Setting

Shutter

Band

Press.

Press.

Flange

 

 

CWH-780

CF800

BCF403

CF100KJ

6.00

5.00x60P

3

7

0

N/A

150

51628

4.75"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CWH-1200

CF1000

BCF101

CF66KD

9.00

5.50x60P

3

5

N/A

N/A

275

51629

4.75"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CWH-1200

CF1400

BCF205

CF66KD

9.00

5.50x60P

3

30

50

150

300

51629

4.75"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CWH-1510 CF2300A BCF304

CF66KG

12.00

7.00x45SS

3

30

50

150

300

51630

4.75"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CWH-1810 CF2300A BCF304

CF66KG

14.00

8.00x60P

3

30

50

150

300

51630

4.75"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CWH-2460

CF2300A

BCF304

CF66KG

18.00

10.00x60P

3

30

50

150

300

51630

4.75"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.

 

Page 10

Image 11
Contents Commercial OIL Burners Series Boiler Bryan SteamG515 BuderusG215 G315G615 Series Boiler Burnham CorporationFDO CG66KG MPCPF-5 V11 V9A CWH Series Boiler Columbia BoilerHRT FW Series Boiler Crown BoilerVH8 GT300 Series Boiler DeDietrichDunkirk GT210 Series BoilerFST Easco BoilerESP PLW Series Boiler SM4SM5 Cyclone Series Boiler HurstCO-XC National Combustion7FDA Series Boiler Peerless BoilerJO-FDASeries Boiler EC/ECT Series BoilerLCE SC05 Liberty Slant/FinSmith Cast Iron Boilers 19A BB-14 Starfire II Series Boiler Utica BoilerHE28 F200 Vaillant CorporationWeil McLain 00x60B D 1-1/2 CF2300 BCF304 88-2 Page Beckett Corporation
Related manuals
Manual 16 pages 32.8 Kb Manual 16 pages 21.32 Kb

CF375, CF800, CF2300A, CF2500A, CF3500A specifications

The Beckett CF series, encompassing models CF3500A, CF2500A, CF2300A, CF800, and CF375, represents a robust lineup of oil burners designed for residential and commercial heating applications. These models are engineered for efficiency, reliability, and ease of use, making them a preferred choice among HVAC professionals and homeowners alike.

The CF3500A is a high-capacity model that excels in providing consistent heating for larger spaces. With a firing rate of up to 3.5 gallons per hour, it is equipped with advanced nozzle technology that improves fuel atomization, resulting in better combustion efficiency. This model features a compact design, making it easy to install in various settings, and it includes an integrated control module for straightforward operation.

The CF2500A offers impressive performance with a moderate firing rate suitable for mid-sized buildings. It incorporates Beckett's patented Clean Cut design which minimizes smoke and reduces emissions. This model also comes with a diagnostic LED display, allowing for quick identification of system status and potential issues, enhancing maintenance efficiency.

The CF2300A is tailored for smaller applications while still maintaining a strong performance profile. Its compact size does not compromise power, as it utilizes advanced combustion technologies to ensure effective heating. The user-friendly interface allows for effortless adjustments, and its low profile design fits into tight spaces, making it ideal for residential use.

For applications requiring versatility, the CF800 stands out with a multi-fuel capability, allowing it to run on both oil and biodiesel. It boasts an energy-efficient design that contributes to cost savings over time. The CF800's unique air delivery system enhances combustion efficiency, reducing noise levels and improving overall comfort in the living environment.

Finally, the CF375 is designed for high-efficiency performance in professional settings. Its durable construction ensures long-lasting service, and it is equipped with advanced control systems that optimize fuel delivery and combustion. This model is particularly noted for its low emissions, aligning with modern environmental standards while providing reliable heating.

Together, the Beckett CF series exemplifies cutting-edge technology and engineering excellence, catering to diverse heating needs. Each model is a testament to Beckett’s commitment to energy efficiency, performance, and environmental responsibility, making them suitable choices for both residential and commercial heating applications.