Commercial Gas Burner OEM Setup Guide

Weil McLain 80

 

Boiler

Burner

Firing Mode

Rate

Manifold

Head Type

Damper

Shutter

Air Tube

 

 

 

 

 

MBH

Pressure

/ Head

Setting

Band

Insertion

 

 

 

 

 

 

in. water

Setting

Blue / Red

Settings

Inches

 

 

380

CG10

Low Fire Start

336

0.7

/

1.8

10.1S / 10.1

-

3 / 0

3.00"

 

 

480

CG10

Low Fire Start

491

0.8 / 1.45

10.3S / 10.3

-

6 / 0

3.00"

 

 

580

CG10

Low Fire Start

639

1.6

/ 3.11

10.4S / 10.4

-

8 / 0

3.00"

 

 

680

CG10

Low Fire Start

787

1.7

/

3.3

10.5S / 10.5

-

8 / 1

3.00"

 

 

780

CG10

Low Fire Start

943

1.0

/

3.2

10.6S / 10.6

-

10 / 3

3.00"

 

 

780

CG15

Mod

461 / 945

1.0

/

4.2

15.1S / 15.1

22 / 50

-

4.00"

 

 

880

CG10

Low Fire Start

1067

1.0

/

4.1

10.6S / 10.6

-

10 / 4

4.00"

 

 

880

CG15

Mod

542 / 1072

0.9

/

3.5

15.2S / 15.2

25 / 47

-

4.00"

 

 

980

CG15

Mod

641 / 1230

0.95 /

3.49

15.3S / 15.3

28 / 65

-

4.00"

 

 

1080

CG15

Mod

742 / 1392

0.8

/

3.0

15.4S / 15.4

28 / 62

-

4.00"

 

 

1080

CG25

Mod

682 / 1378

0.75

 

/ 3.0

25.1S / 25.1

15 / 42

-

4.00"

 

 

1180

CG25

Mod

774 / 1526

0.73

/

2.83

25.2S / 25.2

21 / 43

-

4.00"

 

 

1280

CG25

Mod

787 / 1670

0.75 / 3.1

25.2S / 25.2

21 / 48

-

4.00"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Weil McLain 88

 

Boiler

Burner

Firing Mode

Rate

Manifold

Head Type

Damper

Shutter

Air Tube

 

 

 

 

 

MBH

Pressure

/ Head

Setting

Band

Insertion

 

 

 

 

 

 

 

in. water

Setting

Blue / Red

Settings

Inches

 

 

488 / 488R

CG10

Low Fire Start

995

1.0

/ 3.8

10.6S / 10.6

-

10 / 4

4.00"

 

 

488 / 488R

CG15

Mod

550

/ 991

0.9

/ 3.2

15.2S / 15.2

25 / 45

-

4.00"

 

 

588

CG25

Mod

656 / 1382

0.75 / 3.1

25.1S / 25.1

17 / 40

-

4.00"

 

 

688

CG25

Mod

774 / 1703

0.76

/ 3.62

25.2S / 25.2

21 / 51

-

4.00"

 

 

788

CG50

Mod

888 / 2053

0.55 / 2.5

50.1S / 50.1

17 / 32

-

4.00"

 

 

888

CG50

Mod

1040

/ 2350

0.55 / 2.2

50.2S / 50.2

20 / 37

-

4.00"

 

 

988

CG50

Mod

1044

/ 2713

0.54

/ 3.77

50.2S / 50.2

20 / 42

-

4.00"

 

 

988R

CG50

Mod

1044

/ 2482

0.55

/ 3.12

50.2S / 50.2

20 / 39

-

4.00"

 

 

1088

CG50

Mod

1228

/ 3103

0.55

/ 3.52

50.3S / 50.3

21 / 53

-

4.00"

 

 

1088R

CG50

Mod

1228

/ 2887

0.56 / 3.1

50.3S / 50.3

21 / 42

-

4.00"

 

 

1188

CG50

Mod

1443

/ 3392

0.57

/ 3.14

50.4S / 50.4

23 / 50

-

4.00"

 

 

1288

CG50

Mod

1443

/ 3753

0.55

/ 3.73

50.4S / 50.4

23 / 75

-

4.00"

 

 

1388

CG50

Mod

1700

/ 4113

0.59

/ 3.45

50.5S / 50.5

26 / 70

-

4.00"

 

 

1488

CG50

Mod

1762

/ 4488

0.6

/ 3.2

50.5S / 50.5

26 / 90

-

4.00"

 

Image 10
Contents Commercial GAS Burners Commercial Gas Burner OEM Setup Guide Armstrong LG-14Buderus SB615 Buderus G315Buderus SB735 Burnham MPC BurnhamBurnham V9A CrownSmith 19A Smith 28ASmith HE28 Peerless LC/LCE Peerless SC/SCTPeerless TC Scotch MarineWeil McLain Weil McLain 88 Series Beckett Corporation

CG10(A) specifications

The Beckett CG10(A) is a high-efficiency gas-fired boiler renowned for its innovative design, reliable performance, and ease of installation. This unit is recognized for its advanced technologies that enhance comfort, optimize energy usage, and reduce environmental impact.

One of the standout features of the CG10(A) is its compact size, making it ideal for residential applications where space is a premium. The design ensures that it can easily fit into smaller utility rooms or closets without sacrificing performance. Weighing only 140 pounds, the boiler is also lightweight, simplifying the installation process.

The CG10(A) is engineered with a durable cast iron heat exchanger that maximizes heat transfer while retaining strength and longevity. This heat exchanger is designed to provide consistent and efficient heating throughout the home, ensuring that hot water and space heating demands are met effectively.

In terms of efficiency, the CG10(A) boasts an impressive Annual Fuel Utilization Efficiency (AFUE) rating, making it one of the more efficient options on the market. The unit incorporates a state-of-the-art electronic ignition system that eliminates the need for a standing pilot light, further enhancing energy savings. Additionally, the boiler features an integrated air-fuel ratio control that optimizes combustion for improved efficiency and lower emissions.

Another significant characteristic of the CG10(A) is its quiet operation. Designed with sound-dampening technology, the boiler operates at a whisper-quiet level, ensuring that it doesn’t disturb the peace of home environments. This characteristic, combined with user-friendly controls, makes it a practical and functional choice for homeowners.

The unit also supports a variety of venting options, including direct vent and traditional chimney venting, allowing versatility in installation based on existing systems. Furthermore, Beckett provides excellent service support and warranty options, ensuring customer satisfaction and peace of mind.

Overall, the Beckett CG10(A) stands out in the industry for its advanced technology, efficiency, and user-friendly features. It’s an ideal solution for homeowners looking to invest in a reliable, high-performance heating system that prioritizes both comfort and sustainability. With its combination of durability and innovation, the CG10(A) is a solid choice for modern home heating needs.