Lochinvar 1.0- 1.3- 1.5 operation manual Diagrams, LOW Voltage 120 VAC High Voltage

Page 20

Modbus Instructions

7Diagrams

Figure 7-1Ladder Diagram_Part 1

BOX DEPICTS

OPTIONAL ITEMS

LOW VOLTAGE 120 VAC HIGH VOLTAGE

CONTROL

CONTROL

MODULE 1

 

MODULE 2

LOUVER

 

 

RELAY 1

X8

 

X6-8

X8

 

 

 

 

X5-7

 

 

X5-7

 

 

 

 

24V

LOUVER

 

24V

 

 

 

 

X5-4

RELAY 2

 

X5-4

 

FLAP

 

AIR PRESSURE

FLAP

AIR PRESSURE

 

VALVE

 

SWITCH

VALVE

SWITCH

 

 

 

 

 

 

 

X5-14

 

 

X5-14

 

 

 

HI-LIMIT

 

 

HI-LIMIT

X6-8

 

 

 

 

 

 

 

 

 

 

 

X5-8

 

 

 

INLET

 

 

 

 

INLET

 

X5-8

SENSOR

 

 

 

 

SENSOR

 

 

 

 

 

 

X5-1

 

 

X5-1

OUTLET

 

 

 

X5-9

OUTLET

 

X5-9

SENSOR

 

 

 

SENSOR

 

 

 

 

 

X5-2

 

 

X5-2

FLUE

 

 

 

 

FLUE

 

 

SENSOR

 

 

 

 

SENSOR

 

 

 

 

 

 

X5-3

 

 

 

 

BLOCKED

 

 

 

X5-3

 

 

 

 

 

 

DRAIN

 

 

 

 

 

 

AUTO RESET

X5-10

AUTO RESET

X5-10

 

 

 

HIGH LIMIT

 

HIGH LIMIT

GAS VALVE

 

 

X2-2

 

GAS VALVE

X2-2

 

 

 

 

 

GAS VALVE

 

 

GAS VALVE

 

 

 

X2-1

RELAY

 

X2-1

RELAY

BLOWER

 

 

1

X5-5

BLOWER

1

X5-5

 

 

 

2

X5-13

 

2

X5-13

 

 

 

4

X5-6

 

4

X5-6

 

 

 

5

X5-12

 

5

X5-12

 

 

 

TR1

 

 

TR1

 

 

 

 

X1-7

 

 

X1-7

 

SPARK

 

 

FLAME ROD

SPARK

FLAME ROD

 

 

 

 

 

 

ROD

 

 

 

 

ROD

 

 

CAUTION

HIGH VOLTAGE SPARK LEAD

 

CAUTION

HIGH VOLTAGE SPARK LEAD

SHIELD

CASCADE

RS485

SHIELD

TANK

SENSOR

OUTDOOR

SENSOR

SYSTEM

SENSOR

-

EXTERNALCONTROL 10VDC

+

SHIELD

MOD BUS

RS485

SHIELD

CONNECTION BOARD

CN3

CN4-3

CN3-16

 

CN3-15

CN4-1

 

CN3-14

CN4-2

 

CN3-13

CN4-4

 

CN3-12

CN4-6

 

CN3-11

 

CN3-10

CN4-5

 

CN3-9

CN4-8

 

CN3-8

CN4-7

 

CN3-7

CN4-9

 

CN3-6

 

CN3-5

CN4-10

 

CN3-4

 

CN3-3

 

CN3-2

 

CN3-1

 

4CONTROL MODULE 1

X4-3

X4

X4-1

X4-2

X4-4

X4-6

X4-5

X4-8

X4-7

X4-9

X4-10

MOD BUS

KIT

X4-3

X4-1

X4-2

X4-4

CONTROL MODULE 2

X4

20

NOTES:

1. Where possible, switches are shown without utilities (gas, water or

LADDER DIAGRAM

electricity) connected to the unit. As such, actual switch states mayLBL20058 REV E vary from those shown on diagrams depending upon whether utilities

are connected or a fault condition is present.

2. See wiring diagram for additional notes.

Image 20 Contents
Modbus Communication Instructions Sync Models 1.0 1.3Contents Configuration AddressingTiming Specifications Data Transmission ModeModbus Board Diagnostics ParityModbus Function Set DecModbus Exception Codes NameSync Boiler Memory Map Memory MapPrimary Data Tables Configuration Bits Holding RegistersWiring Requirements Physical WiringSecondary Secondary Smart Touch Control Module Primary Typical Boiler System Wiring 4Control LocationPhysical Configuration Cascade with individual Monitoring Unit Operation with Modbus Communications Demand ConfigurationUnit Operation Hot Water Generation DHW with direct control Monitoring Only DHW with remote control Cascade Rate and Temperature Conversions TemperatureRate Deg C Deg F VoltagesTroubleshooting Installation / Replacement Procedure Lockout Codes Input Registers 30016Diagrams LOW Voltage 120 VAC High Voltage2Ladder DiagramPart 3Wiring Diagram