General notes
Clearances
Your installer will have provided adequate space around the appli- ance for safety and servicing access. Do not restrict this space with the addition of cupboards, shelves etc. next to the appliance.
10 mm | |
|
|
10 mm | |
|
|
In Front | 600 mm |
|
|
Above Casing (Vertical Flue) | 200 mm |
|
|
Above Flue Turret | 30 mm |
|
|
Below | 200 mm |
|
|
Table 1
Room thermostat
A room thermostat should be fitted to control the central heating. Refer to the instructions supplied with the thermostat for informa- tion on siting and setting.
Thermostatic radiator valves
It is recommended that this type of valve is fitted to all the radia- tors. It is a requirement that they are fitted, at least, in the sleeping areas.They should conform to the requirements of BS2767:10.
Time Control
Separate time control of the space heating and the hot water sys- tem is required using a
Cylinder Thermostat
A cylinder thermostat must be fitted to the cylinder which, when used with a motorised valve, will give close control of the water temperature.
6 720 611 138 GB (03.11) | 7 |