White Rodgers 1E65-144 specifications Operator Save these instructions for future use

Page 1

1E65-144

Non-programmable Electronic Digital Thermostat

For Line Voltage Applications

INSTALLATION AND OPERATION INSTRUCTIONS

Operator: Save these instructions for future use!

DESCRIPTION

The 1E65-144 thermostat has been designed to control electric heating systems such as baseboard heaters, radiant floors, radiant ceilings and convectors.

The adapter plate is used to offset the thermostat when an obstruction

 

prevents the thermostat from being mounted directly to the junction

Temperature

box.

Display

The thermostat cannot be used with the following:

-a resistive load under 2 A

-a resistive load over 16.7 A

-systems driven by a contactor or a relay (inductive load)

-central heating systems

Parts Supplied:

Available Accessories:

One (1) thermostat

F61-2642 Adapter Plate

Two (2) 6-32 pan head screws

 

Temperature

Adjustment

Buttons

Light

Button

System

Switch

SPECIFICATIONS

Supply: 120/240 VAC, 50/60 Hz

Minimum load: 2 A (resistive only) 500 W @ 240 VAC 250 W @ 120 VAC

Maximum load: 16.7 A (resistive only) 4000 W @ 240 VAC 2000 W @ 120 VAC

Setpoint range:

7°C to 32°C (45°F to 90°F)

Display range:

0°C to 37°C (32°F to 99°F)

Display resolution:

0.1°C (1°F)

Shipping:

–20°C to 50°C (-4°F to 120°F)

Approval:

 

PRECAUTIONS

! WARNING

*Failure to read and follow all instructions carefully before installing or operating this control could cause personal injury and/or property damage.

*All wiring must conform to local and national electrical codes and ordinances.

*To prevent electrical shock,personal injury,and/or equipment damage, disconnect electric power to system at main fuse or circuit breaker box prior to installation or service.

INSTALLATION

Installation should be done by a qualified heating and air conditioning contractor or licensed electrician.

Loosen the screw holding the thermostat cover to the base, open cover on hinge and remove the cover.

Optional: Use the adapter plate accessory if you need to offset the mounting holes on the junction box. Align and affix the wall plate to the electrical junction box using two 6-32 flat head screws included with the plate.

Screw

White-Rodgers is a division

PART NO. 37-6862D

of Emerson Electric Co.

Replaces 37-6862C

www.white-rodgers.com

0839

Image 1
Contents Precautions SpecificationsInstallation Operator Save these instructions for future useWire Installation InstallationOperation Nectors approved for 12 AWG onlySpécifications Utilisateur Conserver ces directives à titre de référencePrécautions Installation à 2 fils Installation suiteUtilisation Logués pour les conducteurs de calibre 12 AWG

1E65-144 specifications

The White Rodgers 1E65-144 is a versatile and reliable thermostat designed for heating and cooling systems in residential and light commercial applications. Known for its user-friendly interface and a range of advanced features, it offers optimal comfort and energy efficiency.

One of the standout features of the 1E65-144 is its digital display, which provides clear and easy-to-read information about current temperature settings and system status. The thermostat has a simple, intuitive interface, making it accessible even for users who are not particularly tech-savvy. The large buttons allow for quick adjustments, ensuring that you can modify the settings on the fly.

The White Rodgers 1E65-144 supports both heating and cooling operations, making it a versatile choice for year-round comfort. It is compatible with a variety of HVAC systems, including conventional gas, oil, and electric systems, as well as heat pumps. This compatibility makes it a reliable option for many households, regardless of the existing heating and cooling setups.

Energy efficiency is a key focus of the 1E65-144, which includes programmable scheduling options. Users can set different temperatures for various times of the day, allowing for significant energy savings by not heating or cooling a space when it is unoccupied. This feature not only helps reduce energy bills but also supports environmentally friendly practices by decreasing overall energy consumption.

Additionally, the 1E65-144 comes equipped with advanced temperature control algorithms that enhance precision in maintaining the desired temperature. This technology minimizes temperature fluctuations, providing a more stable and comfortable environment.

Installation of the White Rodgers 1E65-144 is straightforward, thanks to its user-friendly design and comprehensive installation instructions. Most users can complete the installation process without the need for professional assistance, making it an appealing choice for DIY enthusiasts.

In summary, the White Rodgers 1E65-144 thermostat combines advanced technology, user-friendly features, and energy efficiency, making it an ideal option for those seeking reliable temperature control. Its compatibility with various HVAC systems, programmable settings, and straightforward installation process all contribute to its popularity among consumers looking to enhance their home comfort.