White Rodgers 1F85ST-0422 specifications INSTALLER/CONFIGURATION Menu, Press Displayed, Comments

Page 4

INSTALLER/CONFIGURATION MENU

With thermostat in Heat, Cool or Auto, in normal operation, press the Menu button for at least 5 seconds. The display will

show item #1 in the table below. Press Menu to advance to the next menu item. Press or to change an item option. Shaded items are not available to 1F86.

INSTALLER/CONFIGURATION MENU

MENU

 

 

PRESS

DISPLAYED

Press

 

 

or

 

 

 

to

COMMENTS

 

 

 

 

 

 

 

REF.

HP

SS

BUTTON

(FACTORY DEFAULT)

select from listed options

1

1

1

MENU

(EM2)

bC1, ES1

 

Selects Multi-Stage (EM2 No Heat Pump),

 

 

 

 

 

 

 

 

 

 

 

 

 

Heat Pump 1 (bC 1, 1 compressor),

 

 

 

 

 

 

 

 

 

 

 

 

 

or Single Stage (ES1)

2

2

2

MENU

(GAS) for ES1 or EM2

 

 

ELE

 

GAS setting: furnace controls the blower

 

 

 

 

(ELE) for bC

 

 

 

 

 

 

 

 

ELE setting: thermostat controls the blower

3

3

3

MENU

CE (0)

1, 2, 3, 4, 5, 6

 

Selects Cool Savings

 

 

 

 

(Disabled)

 

 

 

 

 

 

 

 

Value 1 (low) to 6 (high), Value 0 Disables Feature

4

4

4

MENU

E (On)

 

 

OFF

 

Selects Energy Management Recovery (EMR)

 

 

 

 

 

 

 

 

 

 

 

 

 

On or OFF.

5

5

MENU

CR Calor (ME)

 

AL, bA

 

Adjustable Anticipation:

 

 

 

 

 

 

 

 

 

 

 

 

 

Selects heating cycle rate for MS or SS

6

5

MENU

CR Bomba de Calor

 

AL, bA

 

Adjustable Anticipation (Heat Pump) (only

 

 

 

 

(ME)

 

 

 

 

 

 

 

 

when heat pump selected in #1)

7

6

6

MENU

CR Frio (ME)

 

AL, bA

 

Adjustable Anticipation:

 

 

 

 

or

 

 

 

 

 

 

 

 

Selects the cycle rate for cooling

 

 

 

 

CR Aux (FA)

 

 

AL

 

(only when Em 2 or ES 1 is selected in item 1.)

 

 

 

 

 

 

 

 

 

 

 

 

 

or Selects the cycle rate for Emergency

 

 

 

 

 

 

 

 

 

 

 

 

 

mode and Auxiliary stage if Heat Pump

 

 

 

 

 

 

 

 

 

 

 

 

 

is selected in item 1.

8

7

7

MENU

Cd (OFF)

 

Cd On

 

Compressor Lockout Time

9

8

8

MENU

Frio Off

Calor Frio Off,

 

System Mode Configuration

 

 

 

 

 

Calor Off with Vent icon,

with Automatic Changeover capability

 

 

 

 

Calor Auto

Calor Off without Vent

 

 

 

 

 

 

icon Frio Off, Auto Off

 

10

9

9

MENU

L (On)

 

L OFF

 

Selects Display Light On or OFF

11

10

10

MENU

0

1 AL, 2 AL, 3 AL, 4 AL,

Adjustable Ambient Temperature Display

 

 

 

 

(current temperature)

1 bC, 2 bC, 3 bC, 4 bC

 

12

11

11

MENU

°F

 

 

°C

 

Selects Fahrenheit/Celsius Temperature Display

13

12

12

MENU

L Calor

L 62 to L 89

 

Selects Limited Calor (HEAT) Range

 

 

 

 

(90)

 

 

 

 

 

 

 

 

 

14

13

13

MENU

L Frio

L 46 to L 82

 

Selects Limited Frio (COOL) Range

 

 

 

 

(45)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

14

14

MENU

P3

 

P0, P2

 

Defaults for 5-1-1 programming (P3) but non-

 

 

 

 

 

 

 

 

 

 

 

 

 

programmable (PO) or 5-2 programming (P2)

 

 

 

 

 

 

 

 

 

 

 

 

 

is available on most models.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

15

15

MENU

Calor AP (On)

 

 

OFF

 

Automatic Schedule for heat mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

NA to Cool only system.

17

16

16

MENU

Frio AP (On)

 

 

OFF

 

Automatic Schedule for cool mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

NA to Heat only system.

18

17

MENU

Calor AL (On)

 

 

OFF

 

Fast Heat option may be disabled by

 

 

 

 

 

 

 

 

 

 

 

 

 

selecting OFF. NA to ES config.

 

 

 

 

 

 

 

 

 

 

 

 

 

NA to Cool only system.

19

18

MENU

Frio AL (On)

 

 

OFF

 

Fast Cool option may be disabled by ES or bC

 

 

 

 

 

 

 

 

 

 

 

 

 

selecting OFF. NA to ES config.

 

 

 

 

 

 

 

 

 

 

 

 

 

NA to Heat only system.

20

19

17

MENU

Hv (On)

 

 

OFF

 

Selects Automatic daylight Savings Time

 

 

 

 

 

 

 

 

 

 

 

 

 

option On or OFF.

21

20

18

MENU

Cambiar Filtro (OFF)

 

 

On

 

Selects Filter Change-out Indicator On or OFF.

 

 

 

MENU

Cambiar Filtro (200 h)

25-1975 h

 

Change Filter time in 25 hour increments. This

 

 

 

 

 

 

 

 

 

 

 

 

 

menu only appears if On is selected in above.

22

21

19

MENU

Frio On (o)

Calor On (b)

 

Selects operation of the reversing valve terminal

 

 

 

 

 

 

 

 

 

 

 

 

 

(O/B) output as an O or B terminal.

 

22

20

Arrancar

 

 

 

 

 

 

 

 

 

Returns to Normal Operation

4

Image 4
Contents Specifications ApplicationsSave these instructions for future use IndexInstallation Wiring ConnectionsInstalling New Thermostat Remove Old ThermostatDisplays Adjuste Set for setpoint when in Run Program mode Llamar Servicio Call For Service indicates a faultThermostat Quick Reference Home Screen DescriptionINSTALLER/CONFIGURATION Menu Button Factory DefaultPress Displayed PressGrams per week can be toggled to P2 or P0 by pressing Calor ES1, EM2 Frio ES1, EM2 Bomba de Calor bC1 Aux bC1Menu will be skipped Choose the Vent Setting Auto or On Manual Operation for Non-Programmable ModeProgram Override Temporary Override Set Current Time and DateEnter the Cooling Program Energy Saving Energy Star Factory Pre-ProgramPlanning Your Program Important Worksheet for Re-Programming 5/2 Day and 5+1+1 Day ProgramSymptom Possible Cause Correction Action TroubleshootingReset Operation

1F85ST-0422 specifications

The White Rodgers 1F85ST-0422 is a renowned programmable thermostat that caters to the needs of both residential and commercial applications. Recognized for its user-friendly interface and advanced features, this thermostat is designed to provide optimal comfort while ensuring energy efficiency.

One of the standout features of the 1F85ST-0422 is its 7-day programmable scheduling. Users can customize heating and cooling schedules for each day of the week, allowing them to set specific temperature preferences for different times of the day. This flexibility not only enhances comfort but also promotes energy savings by reducing usage during non-peak hours.

The thermostat boasts a large backlit display, which is easy to read, even in low-light conditions. The touchscreen interface simplifies navigation, making it intuitive for users to adjust settings or review programming schedules. The visual feedback provided by the display ensures that users can monitor their climate control at a glance.

This model incorporates a Smart Recovery feature, which starts the heating or cooling system ahead of the scheduled start time, ensuring that the desired temperature is reached exactly when intended. This proactive approach minimizes temperature fluctuations and enhances overall comfort in the home or workspace.

Another significant technological aspect of the White Rodgers 1F85ST-0422 is its compatibility with various heating and cooling systems, including conventional, heat pumps, and multi-stage systems. This versatility makes it an excellent choice for a wide range of installations.

The thermostat is also equipped with advanced energy management and diagnostic features. Users receive alerts for maintenance needs, such as filter changes, which helps to ensure the continued efficiency of the HVAC system. Additionally, the thermostat's energy use reports provide insights into consumption patterns, enabling users to make informed decisions about their heating and cooling usage.

In terms of installation, the White Rodgers 1F85ST-0422 is designed for straightforward mounting and setup. With the included user manual and clearly labeled terminals, even those with minimal technical expertise can install it with ease.

In summary, the White Rodgers 1F85ST-0422 is a feature-rich programmable thermostat that combines advanced technology, user-friendly design, and energy-saving capabilities, making it a smart choice for anyone looking to optimize their indoor climate control.