1F80-224
Programmable Electronic Digital Thermostat
INSTALLATION AND
OPERATIONINSTRUCTIONS
Operator: Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.
DESCRIPTION
Your new
Features:
•Simultaneous heat and cool program storage
•Preprogrammed temperature control
•Four separate time/temperature settings
•LCD continuously displays setpoint, and alternately displays time and room temperature
•Temperature override until next program period
•Manual program override (HOLD temperature)
•Temporary HOLD
•°F/°C convertibility
•Temperature range 45° to 90°F
•RC, RH, W, Y, G , O and B terminals
•B and O terminals for single stage heat pumps (no auxiliary heat) or damper operation
•Program storage in case of power loss
•2 “AA” Energizer® alkaline batteries included
This thermostat is intended for use with a low voltage system; do not use this thermostat with a line voltage system. If in doubt about whether your wiring is millivolt, line, or low voltage, have it inspected by a qualified heating and air conditioning contractor or electrician.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical codes and ordinances.
This control is a precision instrument, and should be handled carefully. Rough handling or distorting components could cause the control to malfunction.
▲! CAUTION
To prevent electrical shock and/or equipment damage, disconnect electric power to system at main fuse or circuit breaker box until installation is complete.
PRECAUTIONS
▲! WARNING
Do not use on circuits exceeding specified voltage. Higher voltage will damage control and could cause shock or fire hazard.
Do not short out terminals on gas valve or primary control to test. Short or incorrect wiring will damage thermostat and could cause personal injury and/or property damage.
Thermostat installation and all components of the system shall conform to Class II circuits per the NEC code.
ELECTRICAL DATA
Electrical Rating:
8 to 30 VAC 50/60 Hz. or D.C.
0.05to 1.0 Amps (Load per terminal)
1.5Amps Maximum Total Load (All terminals combined)
THERMAL DATA
Setpoint Temperature Range:
45°F to 90°F (7°C to 32°C)
Operating Ambient Temperature Range:
32°F to 105°F
Operating Humidity Range:
0 to 90% RH
Shipping Temperature Range:
SPECIFICATIONS
APPLICATIONS
For use with:
•Standard heat/cool or heat only systems
•Electric heat systems
•Gas or oil fired systems
•Gas systems with intermittent ignition devices (I.I.D.) and/or vent dampers
•Hydronic (hot water or steam) systems
•
•Millivolt systems
DO NOT USE WITH:
•
•Systems exceeding 30 VAC and 1.5 amps
•
| PART NO. | ||
EMERSON ELECTRIC CO. | Printed in U.S.A. | ||
Replaces | |||
9797 REAVIS ROAD | |||
| |||
ST. LOUIS, MISSOURI |
| 0326 | |
|
|