White Rodgers installation instructions 36C03, 36C10, 36C13 and 36D34 Combination Gas Valves

Page 1

36C03, 36C10, 36C13 and 36D34

Combination Gas Valves

(24 Volt, 120 Volt and .750 Volt Models)

INSTALLATION INSTRUCTIONS

Operator: Save these instructions for future use!

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.

DESCRIPTION

The 36C03, 36C13 and 36D34 complete gas controls combine into a single compact package the functions of 3- position gas cock, pressure regulator, 100% shut-off automatic pilot, and main operator. Separate models are available for use on 24 VAC, 120 VAC and .750 VDC systems. These controls can be mounted in any orienta- tion except upside down.

MODELS AVAILABLE

Model No.

Voltage

Gas

Current

36C03

24 volts

Nat.

.23 Amp

36C03A

120 volts

Nat.

.035 Amp

36C03U

.750 volts

Nat.

DC

36C13

24 volts

LP

.23 Amp

36C13A

120 volts

LP

.035 Amp

36C13U

.750 volts

LP

DC

36D34U

.750 volts

Nat./LP

DC

ECO

O

OT

N

 

P OFF

 

 

IL

Terminals

ON

 

PILOT

 

 

OFF

 

The 36C03 and 36C13 models are also available without pressure regulator as a Model 36C10.

The 36D34 model is limited to .750 VDC applications and is equipped with a "quick drop out" power unit for vented gas hearth products.

Pilot Gas Outlet:

Located at outlet end of the valve

Type of Gas

Suitable for all domestic heating gases Pressure Rating: 1/2 lb. per sq. in.

Pressure Regulator Adjust Range (Typical, See Control Label):

Natural Gas:

2.5 to 5.0" W.C.

LP Gas:

7.5 to 12" W.C.

Ambient Temperature: -40° to 175°F

Thermocouple:

(24V & 120V types): Use W-R Type HO6

(.750V Quick Drop Out Power Unit for

36D34 models only): Use W-R Type H19E

Pilot Generator (.750 volt types):

Use W-R Type G01A-32

Mounting: Any position except upside-down

SPECIFICATIONS

PIPE SIZES/CAPACITIES

 

Capacity (BTU/hr) at

 

1” pressure drop across valve

Pipe Size

Nat. Gas

LP Gas

(1000 BTU/cu. ft.,

(2500 BTU/cu. ft.,

(inches)

64 Sp. Gr.)

1.53 Sp. Gr.)

12” x 38

100,000

162,000

12” x 12

230,000

372,600

12” x 34

230,000

372,600

34” x 34

280,000

453,600

Upright, 90° from upright or vertical

UPRIGHT

INLET BOSS

UP OR DOWN

 

LEFT OR RIGHT

ON

OFF

NOTE: Control shown may not be identical to replacement control.

PART NO. 37-5781D

www.white-rodgers.com

Replaces 37-5781C

 

 

0909

Image 1
Contents 36C03, 36C10, 36C13 and 36D34 Combination Gas Valves SpecificationsOperator Save these instructions for future use DescriptionLeaks Immediately Installation Main Piping ConnectionsInstallation cont’d System WiringPilot GAS Connection Pressure Regulator Adjustment Pilot GAS AdjustmentEnergy CUT OFF E.C.O Connection Thermocouple ConnectionFor Your Safety Read Before Lighting Pilot Lighting Instructions PrecautionsPage Page White-Rodgers is a division of Emerson Electric Co