Desa CGN30C, CGN18R installation manual TROUBLE- Shooting, See Cleaning

Page 23

TROUBLE- SHOOTING

OBSERVED

POSSIBLE

 

PROBLEM

CAUSE

REMEDY

 

 

 

Continued

When control knob is pressed in and turned to the PILOT/IGN position, there is spark at ODS/pilot but no ignition

1.Gas supply turned off or manual shutoff valve closed

2.Control knob not pressed in while being turned to PILOT/IGN position

3.Air in gas lines when installed

4.ODS/pilot is clogged

5.Gas regulator setting is not correct

1.Turn on gas supply or open manual shutoff valve

2.Press in control knob while turning to PILOT/IGN position

3.Continue holding down control knob. Repeat igniting operation until air is removed

4.Clean ODS/pilot (see Cleaning and Mainte- nance, page 22) or replace ODS/pilot assembly

5.Replace gas regulator

ODS/pilot lights but

1.

Control knob not fully

1.

Press in control knob

flame goes out when

 

pressed in

 

fully

control knob is

2.

Control knob not

2.

After ODS/pilot lights,

released

 

pressed in long enough

 

keep control knob

 

 

 

 

pressed in 10 seconds

 

3.

Manual shutoff valve

3.

Fully open manual

 

 

not fully open

 

shut-off valve

 

4.

Thermocouple connec-

4.

Hand tighten until

 

 

tion loose at control

 

snug, then tighten 1/4

 

 

valve

 

turn more

 

5.

Pilot flame not touch-

5.

A) Contact local

 

 

ing thermocouple,

 

natural gas company

 

 

which allows thermo-

 

 

 

 

couple to cool, causing

 

B) Clean ODS/pilot

 

 

pilot flame to go out.

 

(see Cleaning and

 

 

This problem could be

 

Maintenance, page 22)

 

 

caused by one or both

 

or replace ODS/pilot

 

 

of the following:

 

assembly

 

 

A) Low gas pressure

 

 

 

 

B) Dirty or partially

 

 

 

 

clogged ODS/pilot

 

 

 

6.

Thermocouple dam-

6.

Replace thermocouple

 

 

aged

 

 

 

7.

Control valve damaged

7.

Replace control valve

Continued

099434

23

Image 23
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information ContentsSafety Information Piezo Ignition System Local Codes Unpacking Product FeaturesSafety Device Producing Adequate Ventilation Fresh AIR ForCombustion VentilationDetermining if You Have a Confined or Unconfined Space Fresh AIRDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Inside Building Fresh AIR for Combustion and VentilationVentilation AIR Ventilation Air From Outdoors Ventilation AIRLocating Heater Installing To WallInstallation Items Check GAS TypeInstalling to Wall Methods For Attaching Mounting Bracket To Wall Installing Heater to WallMounting Bracket Removing Front Panel Of HeaterAttaching Mounting Bracket To Wall Marking Screw LocationsPlacing Heater On Mounting Bracket Installing Bottom Mounting ScrewsCGN30C Connecting to GAS SupplyServicing. Correct all leaks at once Pressure Testing GAS Supply Piping SystemChecking GAS ConnectionsChecking Pressure Testing Heater GAS ConnectionsWhat to do if YOU Smell GAS HeaterPilot Operating HeaterTo Select Heating Level Shutting Off Burner Only pilot stays lit Operating Heater Inspecting BurnerPilot Flame Pattern Shutting Off HeaterGRH/OV 019A ODS/PILOT and Burner Orifice CleaningMaintenance Trouble ShootingTROUBLE- Shooting See CleaningSee Cleaning and Main Technical ServiceHints Replacement PartsParts Under Warranty Parts Not Under WarrantyModel CGN18R GA4000B Model CGN30C GA4010B AccessoriesCentrals FAN KIT GA3100 GA2100AModel CGN18R Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListModel CGN30C Parts List Keep this Warranty Warranty Information