Desa CGN20L, RN30D installation manual Installing Heater to Wall

Page 7

OWNER’S MANUAL

INSTALLING TO WALL

Continued

INSTALLING HEATER TO WALL

Mounting Bracket

The mounting bracket is located on back panel of heater. It has been taped there for shipping. Remove mounting bracket from back panel.

Mounting

Bracket

Figure 5 - Mounting Bracket Location

Removing Front Panel Of Heater

1.Remove two screws near bottom cor- ners of front panel.

2.Lift straight up on grill guard until it stops. Grill guard will slide up about 1/4".

3.Pull bottom of front panel forward, then down.

4.Remove cardboard packing from grill and glass (CGN20[L]) or heat shield (RN30D).

Figure 6 - Removing Front Panel Of Heater

Methods For Attaching Mounting Bracket To Wall

Only use last hole on each end of mounting bracket to attach bracket to wall. These two holes are 16 inches apart from their centers. Attach mounting bracket to wall in one of two ways.

1.Attaching to wall stud

2.Attaching to wall anchor

Attaching to wall stud: This method provides the strongest hold. Insert mounting screws through mounting bracket and into wall studs.

Attaching to wall anchor : This method allows you to attach mounting bracket to hollow walls (wall areas between studs) or to solid walls (concrete or masonry).

Decide which method better suits your needs. Either method will provide a secure hold for the mounting bracket.

Marking Screw Locations

1.Tape mounting bracket to wall where heater will be located. Make sure mounting bracket is level.

2.Mark screw locations on wall (see Figure 7).

WARNING: Maintain minimum clearances shown in Figure 7. If you can, provide greater clear- ances from floor and joining wall.

Note: Only mark last hole on each end of mounting bracket. Insert mounting screws through these holes only.

3.Remove tape and mounting bracket from wall.

11"

16"

Min.

 

AdjoiningWall

 

Only Insert Mounting

32 1/2"

 

 

Screws Through Last

 

 

Min.

 

 

Hole On Each End

 

 

 

 

 

 

 

Floor

 

 

 

 

RN30D

 

 

 

7 1/4"

16"

 

 

 

Min.

 

 

 

AdjoiningWall

Only Insert Mounting

18 3/4"

Screws Through Last

 

Min.

 

 

Hole On Each End

 

 

 

 

 

Floor

CGN20(L)

Figure 7 - Mounting Bracket Clearances

Attaching Mounting Bracket To Wall

Note: Wall anchors, mounting screws, and spacers are in hardware package. The hard- ware package is provided with heater.

Attaching to wall stud method

For attaching mounting bracket to wall studs

1.Drill holes at marked locations using 9/64" drill bit.

2.Place mounting bracket onto wall. Line up last hole on each end of bracket with holes drilled in wall.

3.Insert mounting screws through bracket and into wall studs.

4.Tighten screws until mounting bracket is firmly fastened to wall studs.

Attaching to wall anchor method For attaching mounting bracket to hollow walls (wall areas between studs) or solid walls (concrete or masonry)

1.Drill holes at marked locations using 5/16" drill bit. For solid walls (concrete or masonry), drill at least 1" deep.

2.Fold wall anchor as shown in Figure 8.

Figure 8 - Folding Anchor

3.Insert wall anchor (wings first) into hole. Tap anchor flush to wall.

4.For thin walls (1/2" or less), insert red key into wall anchor. Push red key to “pop” open anchor wings.

IMPORTANT: Do not hammer key!

For thick walls (over 1/2" thick) or solid walls, do not pop open wings.

Figure 9 - Popping Open Anchor Wings For Thin Walls

5.Place mounting bracket onto wall. Line up last hole on each end of bracket with wall anchors.

6.Insert mounting screws through bracket and into wall anchors.

7.Tighten screws until mounting bracket is firmly fastened to wall.

Continued

103568

7

Image 7
Contents What to do if YOU Smell GAS RN30D CGN20 CGN20LUnpacking Safety InformationProduct Features Local CodesUnusually Tight Construction Product IdentificationAIR for Combustion Ventilation Providing Adequate VentilationVentilation Air From Inside Building AIR for Combustion and VentilationDetermining AIR Flow for Heater Location Ventilation AIRVentilation Air from Inside Building Ventilation Air From OutdoorsLocating Heater Installing to WallInstallation Items Check GAS TypeInstalling Heater to Wall Typical Inlet Pipe Diameters Connecting to GAS SupplyInstalling Bottom Mounting Screws Placing Heater On Mounting BracketPsig Pressure Testing Heater GAS ConnectionsPressure Testing GAS Supply Piping System Checking GAS ConnectionsLighting Instructions For Your Safety Read Before LightingManual Lighting Procedure Operating HeaterInspecting Burner Cleaning and MaintenanceObserved Problem Possible Cause Remedy TroubleshootingTroubleshooting Ing Gas Connections, Specifications Technical ServiceService Hints AccessoriesRN30D Illustrated Parts BreakdownODS/Pilot KEY Part Number Description QTY Parts ListCGN20 CGN20L Parts List Parts Under Warranty Replacement Parts CentralsParts not Under Warranty 103568 103568 103568 Limited Warranty Comfort Glow VENT-FREE Heaters Warranty Information

CGN20L, CGN20, RN30D specifications

Desa RN30D, CGN20, and CGN20L are innovative models designed to meet the diverse needs of users looking for reliable and efficient solutions in various applications. These models are renowned for their advanced technologies and impressive features that set them apart in the market.

The Desa RN30D is a robust unit primarily known for its high efficiency and durable construction. It operates with a powerful engine that utilizes advanced fuel technology, making it not only environmentally friendly but also cost-effective. This model comes equipped with a state-of-the-art control system that ensures optimal performance and user-friendly operation. The RN30D is ideal for both commercial and residential uses, providing a versatile option for users needing dependable energy solutions.

On the other hand, the CGN20 and CGN20L models focus on providing energy in compact forms. These models feature a lightweight design, which enhances portability without compromising on performance. The CGN20 is tailored for medium-scale applications, while the CGN20L offers additional capacity and features for larger needs. Both models benefit from cutting-edge inverter technology that allows for stable and consistent output, essential for sensitive electronics.

A standout characteristic of the CGN20 and CGN20L is their quiet operation. Noise reduction technologies have been integrated, making them perfect for use in residential areas or noise-sensitive environments. Furthermore, they are designed with enhanced cooling systems, ensuring reliability even during extended usage.

Each of these models includes safety features such as overload protection and low oil shutdown, providing peace of mind to operators. They are also equipped with multiple outlets, allowing users to connect various devices simultaneously.

In summary, the Desa RN30D, CGN20, and CGN20L cater to a broad spectrum of users, from homeowners to businesses. Their combination of durability, efficiency, advanced technology, and safety features makes them an excellent investment for energy solutions. Whether you require substantial power or a compact, portable option, these models deliver unmatched performance tailored to meet your specific energy needs.