Desa FMH26TP installation manual Inspecting Burner

Page 18

PROPANE/LP VENT-FREE FIREPLACE SYSTEM

OPERATING

FIREPLACE

Continued

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Fireplace

1. Turn control knob clockwise Clockwise to the OFF position.

2.Turn off all electric power to the ap- pliance if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise Clockwise to the PILOT position.

THERMOSTAT

CONTROL OPERATION

The thermostatic control used on this fire- place differs from standard thermostats. Standard thermostats simply turn on and off the burner. The thermostat used on this fireplace senses the room tempera- ture. The thermostat adjusts the amount of gas flow to the burner. This increases or decreases the burner flame height. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature.

The control knob can be set to any heat level between HI and LO.

Note: The thermostat sensing bulb mea- sures the temperature of air near the fire- place cabinet. This may not always agree with room temperature (depending on housing construction, installation location, room size, open air temperatures, etc.). Frequent use of your fireplace will let you determine your own comfort levels.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 5 under Light- ing Instructions, page 17.

2.With control knob pressed in, strike match. Hold match to pilot until pi- lot lights.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8, page 17.

OPERATING BLOWER

This blower has three settings: ON, OFF, and AUTO. In the ON position, the blower will operate constantly. In the OFF posi- tion, the blower will not operate. In the AUTO position, the blower will start when the thermostat senses a sufficient increase in firebox temperature.

Note: Your fireplace and thermostat blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on. After the heater modulates to the pilot position, the blower will continue to run. The blower will shut off after the firebox temperature decreases.

Note: It is safe to operate fireplace with blower turned off. However, the blower helps distribute heated air from the fireplace.

Auto/Off/On Switch

ON

OFF

Figure 31 - Auto/Off/On Switch

INSPECTING

BURNER

Check pilot flame pattern and burner flame pattern often.

PILOT FLAME PATTERN

Figure 32 shows a correct pilot flame pattern. Figure 33 shows an incorrect pilot flame pattern. The incorrect pilot flame is not prop- erly heating the thermocouple. This will cause the thermocouple to cool. When the thermo- couple cools, the fireplace will shut down.

If pilot flame pattern is incorrect, as shown in Figure 33

turn fireplace off (see To Turn Off Gas to Appliance)

see Troubleshooting, pages 20 through 22

Thermocouple

Pilot Burner

Figure 32 - Correct Pilot Flame Pattern

Thermocouple

Pilot Burner

Figure 33 - Incorrect Pilot Flame Pattern

18

107106

Image 18
Contents Compact Heat Majic What to do if YOU Smell GASSafety Information PROPANE/LP VENT-FREE Fireplace SystemProduct Identification Product FeaturesLocal Codes UnpackingAssembling Fireplace AssemblyInstalling Log Assembling HoodUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceAIR for Combustion Ventilation Determining FRESH-AIR Flow for Fireplace LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Check GAS Type InstallationInstallation Items Locating FireplaceBUILT-IN Fireplace Installation Rough Opening for Installing in WallOptional Mantel Installation Mantel Clearances for Built-In InstallationInstalling Blower Assembly Installing Blower Accessory GA3450TRemoving Upper Louver Assembly Assembling Brass Trim Brass trim shipped with mantelPlug fan kit into 120-Volt For Built-In Installation Wiring Diagram For Blower Accessory Built-In InstallationConnecting to GAS Supply Extension CordAttaching Wood Base to Solid Floor Connecting Equipment Shutoff Valve to Heater Control Installation Items NeededPressure Testing Fireplace GAS Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections For Your Safety Read Before Lighting Operating FireplaceLighting Instructions Inspecting Burner Burner Flame Pattern Cleaning and MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole CabinetTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement at Service Hints SpecificationsReplacement Parts Technical ServiceIllustrated Parts Breakdown FMH26TPParts List Description QTYAccessories 107106 Warranty Information

FMH26TP specifications

Desa FMH26TP is a versatile and efficient heating solution that caters to a wide range of residential and commercial applications. Renowned for its innovative design and cutting-edge technology, this heater offers exceptional performance along with user-friendly features.

One of the standout characteristics of the FMH26TP is its ability to produce radiant heat quickly and efficiently. Equipped with a powerful heating capacity, it can seamlessly warm up large spaces, making it ideal for workshops, garages, and even outdoor settings. The installation is straightforward, and its compact design ensures that it can fit conveniently in various locations without obstructing valuable space.

The heater utilizes advanced thermal efficiency technologies, which not only enhance its heating performance but also contribute to energy savings. By effectively converting fuel into heat, the FMH26TP minimizes fuel consumption while delivering optimal warmth. This is particularly beneficial for users looking to reduce their energy bills without compromising on comfort.

Safety is a top priority with the Desa FMH26TP. The unit comes with several built-in safety features, including an automatic shut-off system that activates in case of overheating or if it detects any irregular functions. Additionally, the construction of the heater is robust, ensuring durability and longevity. The reliable design means it can withstand the demands of frequent use in various environments.

Another notable feature of the FMH26TP is its ease of operation. Users can conveniently control the heater with a user-friendly interface. It often includes a thermostat, allowing for precise temperature adjustments according to user preferences. Some models are also compatible with remote control systems, further enhancing user convenience.

The Desa FMH26TP is compatible with multiple fuel types, giving users flexibility. Whether powered by propane or natural gas, this heater adapts to the available fuel source, making it a practical choice for many households. Its adaptability ensures that it can serve a broader market, appealing to diverse consumer needs.

In conclusion, the Desa FMH26TP is a reliable heating solution that combines efficiency, safety, and flexibility. With its powerful heating capabilities and user-friendly features, it stands out as an excellent choice for anyone seeking an effective way to keep their spaces warm and comfortable during the colder months.