Enerco MH175KT, MH210KT, MH125KT, MH50KT Start, Stop, Description QTY, Preparing for Operation

Page 4

c. Slide a small washer, spacer, small washer onto the axle next to the wheel.

d. Slide the partially assembled axle through the wheel support frame.

e. Slide the small washer, spacer, and small washer onto the axle next to the wheel support.

f.Slide the wheel then large washer onto the axle and hold in place with the remaining cotter pin.

g.Install the caps over the larger washers to finish the wheel assembly.

2.Position the heater on the wheel support frame assembly with the exit end over the wheels.

3.Use eight screws and nuts to attach the handles to the top of the tank flange. The screws will go through the handles, tank flange and wheel support frame. Install the nuts and finger tight only until all nuts are installed.

4.Tighten all the nuts.

5.Attach cord caddies to handles using No. (14) & No. (5) screws and nuts.

Handle assembly for 125KT, 175KT& 210KT only.

ITEM

PART NO.

DESCRIPTION

QTY

1

24338

Handle, Front

1

2

24338

Handle,Rear

1

3

24339

Wheel Support Frame

1

4

26977

Machine Screw Blk (long)

8

5

26037

Kep Nut Blk

12

6

28746

Axle

1

7

28752

Wheel (8’’ Dia.)

2

7

22110

Wheel (13’’ Dia. 210KT only)

2

8

28751

Cap

2

9

28748

Spacer

2

10

28747

Washer, Small

4

11

28749

Washer, Large

2

12

28750

Cotter Pin

2

13

28754

Ext. Cord Caddy

2

14

27336

Machine Screw Blk (Small)

4

PREPARING FOR OPERATION

1.Check the heater for possible shipping damage. If any is found, immediately notify the factory.

2.Follow all of the "Precautions".

3.Fill the fuel tank with clean kerosene. In extremely cold weather, condensation may develop in the tank and it is recommended that a tablespoon of de-icer be added for each gallon (4 liters) of fuel in the tank. When filling the heater, use at least 2 gallons (8 liters) of fuel. Be sure heater is level and do not overfill. Use a funnel or can with a long fill spout.

IMPORTANT: Before filling fuel tank the first time or after extended storage periods, drain the fuel tank of any moisture or condensation.

4.Locate heater at a safe distance from combustible materials. Models 50K & 75KT is not suitable for use on wood floors or other combustible materials. When used, the heater should rest on suitable insulating material at least 1 inch thick and extending 3 ft. or more beyond the heater in all directions.

START

1.50K: Plug the heater into a grounded 115V, 60 Hz, 1 Ø outlet.

75KT, 125KT, 175KT & 210KT: Turn thermostat to lowest setting, make sure “On/Off” switch is “Off”. Plug the heater into a grounded 115V, 60 Hz, 1 Ø outlet. Turn thermostat to highest setting. Start heater by push toggle switch to “On” position (light signifies switch is in “ON” position). Adjust thermostat to desired setting. Heater will cycle on/off as heat is required.

For all models: In cold weather, starting may be improved by holding a finger over the end of the pressure adjusting screw until the heater starts. This unit is equipped with an interrupt circuit. The reset is located near the power cord. If the unit does not start, press the reset button.

STOP

1.50K: Unplug heater from power source.

75KT, 125KT, 175KT & 210KT: Push “On/Off” switch to “Off” position. For extended shutdown, unplug heater from power source.

RESTART AFTER SAFETY SHUTDOWN (50K, 75KT, 125KT, 175KT & 210KT)

1.Wait 5 minutes.

2.Press reset button.

Enerco Group, Inc. Kerosene Forced Air Heater

4

Operating Instructions and Owner’s Manual

Image 4
Contents Kerosene FORCED-AIR Heater Contents General Hazard WarningSpecifications Operating PrecautionsSafety Precautions Operating InstructionsStart StopDescription QTY Preparing for OperationMaintenance and Storage Daily ScheduleWiring Diagram Parts List 24 4 pcs 37 2 pcs 18 4 pcs For Information Regarding Service Limited WarrantyMR. Heater HeatstarService LE SUR Informations DES Obtenir Pour Instructions LES Soigneusement LisezPcs 2 Câblage DE Schéma Entreposage ET Entretien RéinitialisationDurgence Arrêt UN Après Redémarrage ArrêtDémarrage Fonctionnement LE AvantSpécifications DéballageAvertissement 75KT ET 50K Modèles AUX Relatif AvertissementKérosène AU Pulsé AIR À Chauffage DE Appareil
Related manuals
Manual 8 pages 49.4 Kb

MH125KT, MH210KT, HS50KT, HS75KT, HS125KT specifications

Enerco is well-known in the heating industry for producing reliable and efficient propane and natural gas heaters. Among their popular models are the MH75KT, MH50KT, MH175KT, HS175KT, and HS125KT, each designed to cater to various heating needs while ensuring optimal performance.

The MH75KT is a versatile forced air heater with a maximum output of 75,000 BTUs, making it suitable for larger workshops or construction sites. It features a durable design and portability, allowing users to easily move it wherever heat is needed. This model boasts an innovative ignition system that provides a quick start-up and a safety shutoff feature that enhances user safety.

The MH50KT offers a slightly lower output at 50,000 BTUs, making it ideal for smaller spaces. It is particularly appreciated for its compact design and light weight, allowing it to be transported with ease. Similar to the MH75KT, it utilizes a dependable ignition system and is designed to operate efficiently, maximizing fuel usage to reduce costs.

For more substantial heating requirements, the MH175KT provides an impressive 175,000 BTUs. This model is suited for large warehouses and outdoor spaces. It includes advanced heating technology, such as a high-efficiency fan for even heat distribution, ensuring comfortable temperatures throughout the area. The MH175KT also features built-in safety mechanisms to prevent overheating and carbon monoxide buildup.

The HS175KT and HS125KT models are designed with high-performance indoor use in mind, delivering 175,000 and 125,000 BTUs, respectively. Both heaters utilize Infrared technology, which provides direct heat to objects and people within their radius rather than merely warming the air. This feature makes them highly effective for working environments where instant heat is crucial. The HS series also offers adjustable heat settings, allowing users to customize their heating experience.

All these models come equipped with necessary safety features such as thermocouples and safety shutoff switches, ensuring that users can operate them with peace of mind. In addition, Enerco’s commitment to quality means that each heater undergoes rigorous testing to ensure reliability and durability.

In summary, Enerco’s MH and HS series heaters provide a range of options suitable for various applications, from small workshops to large industrial spaces. Their innovative technology, combined with user-friendly features and safety mechanisms, makes Enerco a trusted choice for effective heating solutions.