Aprilaire 550, 700, 600 VI. Annual Maintenance, VII. Annual Summer Shutdown, Humidifier Control

Page 11

Service hot water, 140° maximum, is recommended with drain type units for increasing capacity and for heat pump applications.

VI. ANNUAL MAINTENANCE

For best performance, we recommend that you replace the Water Panel evaporator in your Aprilaire Humidifier annually with the exception of Model 400 which should be changed twice a season. If you have a Humidifier Control equipped with a water panel timer, the “Change Water Panel” light will be lit (during operation only) when it is time to change your Water Panel.

To purchase a new Water Panel:

Call the installer of your Aprilaire Humidifier. This information is often found on your equipment.

Call your heating and air conditioning dealer.

Use our “Dealer Locator” at: www.aprilaire.com

Look in the Yellow Pages under Humidifying Apparatus or Heating & Air Conditioner Contractors.

If none of the above is successful and you still need information, please feel free to write us.

Purchase only Genuine Aprilaire Water Panels to maintain performance.

After replacing the Water Panel, turn the control knob to the “Test/Reset” position until the “Change Water Panel” light blinks to reset the water panel change indicator timer. (Blower must be operating and furnace calling for heat.) Be sure to turn the control knob back to the normal setting after resetting the timer.

VII. ANNUAL SUMMER SHUTDOWN

1.For Models 400, and 600 close the bypass damper which is a part of the unit, with the use of the small damper handle. For the Model 550, close the bypass damper which is installed in the bypass pipe.

2.Shut off the water supply to the humidifier by closing the saddle valve.

Humidifier Control:

There is no adjustment to the Humidifier Control required for summer shutdown. (Applies to both Automatic and Manual Mode.)

- 9 -

Image 11
Contents For Models 400, 550, 600 Table of Contents Introduction Principle of Operation Page II. Operating Instructions 400, 600 Figure a % Relative Humidity Guide Outdoor Temperature F Dial SettingWinter Higher temperature+40F 45% +30F 40% +20F 35% +10F 30% 25% 20% 15% Be used to determine the RHIII. Operating Instructions Effect of Water CharacteristicsHumidifier Control VI. Annual MaintenanceVII. Annual Summer Shutdown VIII. Periodic Preventative Maintenance Model Set Humidifier Control to its original position Notches Water Panel Front Cover Limited Warranty Page Service and Water Panel Replacement Record Thank you Warranty Registration