Kidde KN-COB-DP-LS Duracell MN1604 or MX1604 Energizer 522 Gold Peak GP1604A, To replace battery

Page 9

7. Maintenance

When replacing the battery, use one of the following approved brands:

• Duracell

MN1604 or MX1604

• Energizer

522

• Gold Peak

GP1604A

These batteries can be purchased where you bought the alarm or at a local hardware store. Use of a different battery may have a detrimental effect on the alarm operation.

The 9 volt battery is not rechargeable. If the 9 volt battery is missing, disconnected, or if the battery’s power is low, a red LED flash will occur once every 15 seconds, accompanied by an audible beep. If this happens, the battery must be replaced. (For model KN-COP-DP-LS with digital display: “Lb” will be displayed alternately with the current CO reading once every second).

To replace battery:

Remove the screw, if it has been used, that is holding the battery door located on the back of the unit. Slide the battery door toward the back oF the alarm to release it. Remove the battery and replace it with one of the approved replacement batteries. Reinstall the back door and replace the screw, if it has been used

IMPORTANT: Constant exposures to high or low humidity may reduce battery life. A good safety measure is to replace the battery at least once a year, or at the same time as you change your clocks for daylight saving time.

After installing or changing the battery, reinstall your alarm. Test your alarm by using the Test/Reset button and check that the green LED is on.

Maintenance Tips

To keep your alarm in good working order, you must follow these steps:

Test the alarm once a week by pressing the Test/Reset button.

Vacuum the alarm cover once a month to remove accumulated dust.

Never use detergents or solvents to clean the alarm. Chemicals can permanently damage or temporarily contaminate the sensor.

Avoid spraying air fresheners, hair spray, paint or other aerosols near the alarm.

Do not paint the unit. Paint will seal the vents and interfere with proper sensor operation.

7. Maintenance

Move the CO Alarm to a remote location, to prevent possible damage or contamination of the sensor, prior to performing any of the following:

Staining or stripping floors or furniture, painting or wall-papering

Using aerosols or adhesives

WARNING: Reinstall the CO Alarm as soon as possible to assure contin- uous protection.

The following is a list of substances that at high levels can damage the sensor or cause temporary readings that are not CO readings:

Ethylene, ethanol, alcohol, iso-propanol, benzene, toluene, ethyl acetate, hydrogen, hydrogen sulfide and sulfur dioxide.

Also most aerosol sprays, alcohol based products, paint, thinner, sol- vent, adhesive, hair spray, after shave, perfume, auto exhaust (cold start) and some cleaning agents.

Image 9
Contents Models KN-COB-DP-LS and KN-COP-DP-LS Carbon Monoxide AlarmImportant Warning Statements WelcomeInformation About Carbon Monoxide Contents of This User’s GuideMid Levels High LevelsLow Levels Conditions That Can Produce Carbon MonoxideModel KN-COB-DP-LS Tamper-Resist FeatureInstallation Locations How to Install Your Alarm Direct Plug Alarm To install Alarm CharacteristicsCarbon Monoxide Alarm Indicator Operating and Alarm CharacteristicsPeak Level Memory Reset MaintenanceBattery Replacement Peak Level MemoryTo replace battery Maintenance TipsDuracell MN1604 or MX1604 Energizer 522 Gold Peak GP1604A Seven Year Limited Warranty

KN-COB-DP-LS, KN-COP-DP-LS specifications

The Kidde KN-COP-DP-LS and KN-COB-DP-LS are advanced carbon monoxide (CO) detectors designed to enhance safety within homes and living spaces. These models feature a host of technologies and characteristics that ensure efficient monitoring and detection of carbon monoxide, a colorless, odorless gas that can pose serious health risks.

One of the standout features of both models is their digital display, which provides real-time readings of CO levels in parts per million (PPM). This feature allows users to quickly evaluate the air quality in their environment. The easy-to-read display is complemented by a battery backup option, ensuring that the detector remains operational even during power outages.

Both detectors utilize a sophisticated electrochemical sensor that is designed to respond quickly to the presence of carbon monoxide. This technology is known for its accuracy and reliability, making it a valuable addition to any home safety system. The detectors are capable of detecting low levels of CO and are programmed to trigger alarms at different thresholds, thus providing early warning to occupants.

In terms of design, the KN-COP-DP-LS and KN-COB-DP-LS are compact and unobtrusive, making them easy to install in various locations around the home, such as hallways, bedrooms, and near fuel-burning appliances. Their sleek profile ensures that they can blend in with existing home decor while still remaining functional.

Another significant characteristic of these models is their built-in test/reset button, which allows users to easily check the functionality of the unit at any time. This feature promotes regular maintenance and ensures that the detector is working correctly. Furthermore, both models offer a loud alarm that sounds at 85 decibels, alerting occupants of dangerous CO levels promptly.

In addition to detecting carbon monoxide, the KN-COB-DP-LS model offers dual functionality by also detecting explosive gases, such as natural gas or propane. This added feature makes it a versatile choice for homeowners, providing an extra layer of protection against multiple hazards.

Both the Kidde KN-COP-DP-LS and KN-COB-DP-LS detectors exemplify innovation in safety technology. With their combination of advanced detection methods, user-friendly features, and reliability, they represent a vital investment for safeguarding health and wellbeing in residential settings.