First Alert SCO500 user manual Installation, Where to Install this Alarm, Avoiding Dead AIR Spaces

Page 3

INSTALLATION

WHERE TO INSTALL THIS ALARM

Minimum coverage for Smoke Alarms, as recommended by the National Fire Protection Association (NFPA), is one Smoke Alarm on every floor, in every sleeping area, and in every bedroom (See “Regulatory Information For Smoke Alarms” for details on the NFPA recommendations).

For CO Alarms, the National Fire Protection Association (NFPA) recommends that a CO Alarm should be centrally located outside of each separate sleeping area in the immediate vicinity of the bedrooms. For added protection, install additional CO Alarms in each separate bedroom, and on every level of your home.

NOTE: For added protection, install an additional Smoke/CO Alarm at least 15 feet (4.6 meters) away from the furnace or fuel burning heat source where possible. In smaller homes or in manufactured homes where this distance cannot be maintained, install the Alarm as far away as possible from the furnace or other fuel burning source. Installing the Alarm closer than 15 feet (4.6 meters) will not harm the Alarm, but may increase the frequency of unwanted alarms.

In general, install combination Smoke and Carbon Monoxide Alarms:

In the hall near every sleeping area. If your home has multiple sleeping areas, install a unit in each. If a hall is more than 40 feet (12 meters) long, install a unit at each end.

On every level of your home, including finished attics and basements.

Inside every bedroom, especially if people sleep with the door partly or completely closed.

At the top of first-to-second floor stairs.

At the bottom of the basement stairs.

For additional coverage, install Alarms in all rooms, halls, and storage areas, where temperatures normally remain between 40˚ F and 100˚F (4˚ C and 38˚ C).

Recommended Placement

SUGGESTED AREAS FOR INSTALLING ￿

SMOKE ALARMS, CO ALARMS, AND COMBO UNITS

KEY:

SMOKE ALARMS

SMOKE ALARM WITH ￿

SILENCE FEATURE

CO ALARMS

BOTH, OR COMBINATION ￿

SMOKE/CO ALARMS

Suggested locations are based on NFPA recommendations (NFPA 72 ￿ for Smoke Alarms and NFPA 720 for Carbon Monoxide Alarms). Always ￿ refer to national and local codes ￿ before beginning any installation.

In new construction AC and AC/DC smoke alarms MUST be interconnected to meet NFPA recommendations.

When installing on the wall, the top edge of Smoke Alarms should be placed between 4 inches (102 mm) and 12 inches (305 mm) from the wall/ceiling line.

When installing on the ceiling, place the Alarm as close to the center as possible.

In either case, install at least 4 inches (102 mm) from where the wall and ceiling meet. See “Avoiding Dead Air Spaces” for more information.

NOTE: For any location, make sure no door or other obstruction could keep carbon monoxide or smoke from reaching the Alarm.

Installing Smoke/CO Alarms in Mobile Homes

For minimum security install one Smoke/CO Alarm as close to each sleeping area as possible. For more security, put one unit in each room. Many older mobile homes (especially those built before 1978) have little or no insulation. If your mobile home is not well insulated, or if you are unsure of the amount of insulation, it is important to install units on inside walls only.

WHERE THIS ALARM SHOULD NOT BE INSTALLED

Do NOT locate this Smoke/CO Alarm:

In garages, furnace rooms, crawl spaces and unfinished attics. Avoid extremely dusty, dirty or greasy areas.

Where combustion particles are produced. Combustion particles form when something burns. Areas to avoid include poorly ventilated kitchens, garages, and furnace rooms. Keep units at least 20 feet (6 meters) from the sources of combustion particles (stove, furnace, water heater, space heater) if possible. In areas where a 20-foot

(6 meter) distance is not possible – in modular, mobile, or smaller homes, for example – it is recommended the Smoke Alarm be placed as far from these fuel-burning sources as possible. The placement recommendations are intended to keep these Alarms at a reasonable distance from a fuel-burning source, and thus reduce “unwanted” alarms. Unwanted alarms can occur if a Smoke Alarm is placed directly next to a fuel-burning source. Ventilate these areas as much as possible.

Within 5 feet (1.5 meters) of any cooking appliance. In air streams near kitchens. Air currents can draw cooking smoke into the smoke sensor and cause unwanted alarms.

In extremely humid areas. This Alarm should be at least 10 feet

(3 meters) from a shower, sauna, humidifier, vaporizer, dishwasher, laundry room, utility room, or other source of high humidity.

In direct sunlight.

In turbulent air, like near ceiling fans or open windows. Blowing air may prevent CO or smoke from reaching the sensors.

In areas where temperature is colder than 40˚ F (4˚ C) or hotter than 100˚ F (38˚ C). These areas include non-airconditioned crawl spaces, unfinished attics, uninsulated or poorly insulated ceilings, porches, and garages.

In insect infested areas. Insects can clog the openings to the sensing chamber.

Less than 12 inches (305 mm) away from fluorescent lights. Electrical “noise” can interfere with the sensor.

In “dead air” spaces. See “Avoiding Dead Air Spaces”.

AVOIDING DEAD AIR SPACES

“Dead air” spaces may prevent smoke from reaching the Smoke/CO Alarm. To avoid dead air spaces, follow installation recommendations below.

On ceilings, install Smoke/CO Alarms as close to the center of the ceiling as possible. If this is not possible, install the Smoke/CO Alarm at least 4 inches (102 mm) from the wall or corner.

For wall mounting (if allowed by building codes), the top edge of Smoke/CO Alarms should be placed between 4 inches (102 mm) and 12 inches (305 mm) from the wall/ceiling line, below typical “dead air” spaces.

On a peaked, gabled, or cathedral ceiling, install first Smoke/CO Alarm within 3 feet (0.9 meters) of the peak of the ceiling, measured horizontally. Additional Smoke/CO Alarms may be required depending on the length, angle, etc. of the ceiling's slope. Refer to NFPA 72 for details on requirements for sloped or peaked ceilings.

3

Image 3
Contents Introduction Table of ContentsWireless Operation USER’S ManualAdding and Linking Additional Onelink Alarms Step by Step Guide to Programming this AlarmFire Safety Tips Basic Safety InformationAvoiding Dead AIR Spaces InstallationWhere to Install this Alarm Where this Alarm should not be InstalledOptional Locking Features If the Smoke Alarm Sounds If Your SMOKE/CO Alarm SoundsWhat to do FIRST-IDENTIFY the Type of Alarm Signal If the CO Alarm SoundsWeekly Testing Regular MaintenanceWhat YOU Need to Know about CO HOW can I Protect MY Family from CO POISONING? Regulatory Information for SMOKE/CO AlarmsRegulatory Information for CO Alarms What Levels of CO Cause AN ALARM?Agency Placement Recommendations Regulatory Information for Smoke AlarmsAbout Smoke Alarms Recommended Locations for Smoke AlarmsCarbon Monoxide Alarm only General Limitations of SMOKE/CO AlarmsTroubleshooting Guide If the Alarm Problem You shouldHow to Obtain Warranty Service Limited Warranty