Firex FPAD, ADC manual What to do in Case of a Fire, Troubleshooting, Ing action

Page 7

Teach household members to crawl along the floor to stay below dangerous smoke, fumes, and gases.

Determine a safe meeting place for all members outside the building.

WHAT TO DO IN CASE OF A FIRE

1.Don’t panic; stay calm.

2.Leave the building as quickly as possible. Touch doors to feel if they are hot before opening them. Use an alternate exit if necessary. Crawl along the floor, and DO NOT stop to collect anything.

3.Meet at a pre-arranged meeting place outside the building.

4.Call the fire department from OUTSIDE the building.

5.DO NOT GO BACK INSIDE A BURNING BUILDING. Wait for the fire department to arrive.

These guidelines will assist you in the event of a fire. However, to reduce the chance that fires will start, practice fire safety rules and prevent hazardous situations.

!

 

TROUBLESHOOTING

DANGER:

Always turn off power at main fuse box or

 

 

circuit breaker before taking trouble- shoot-

!

 

ing action.

 

WARNING:

DO NOT disconnect battery or AC power

 

 

to quiet an unwanted alarm. This will

 

 

remove your protection. Fan the air or

 

 

open a window to remove smoke or dust.

 

 

 

 

 

PROBLEM

 

SOLUTION

 

 

 

 

Smoke alarm does not

1. Check that AC power

 

sound when tested.

is turned on.

 

NOTE: Push test button for

2. Turn off power. Remove

 

smoke alarm from

 

at least five (5) seconds

mounting plate and check

 

while testing!

 

that connector plug is

 

 

securely attached.

 

 

 

 

 

 

3. Clean smoke alarm.

 

 

 

 

LED blinks and alarm beeps

Battery is low – REPLACE

 

simultaneously every 60

IT IMMEDIATELY!

 

seconds.

 

 

 

 

 

 

LED blinks and 30 seconds

Unit inoperable. REPLACE

 

later alarm beeps – repeats at

OR RETURN FOR REPAIR

 

60 second intervals.

IMMEDIATELY!

 

 

 

 

Smoke alarm beeps about

Turn off power and

 

once a minute.

 

replace battery. See

 

 

 

“Battery Replacement”

 

 

 

in the MAINTENANCE AND

 

 

 

CLEANING section.

 

 

 

 

Smoke alarm sounds

1. Clean smoke alarm.

 

unwanted alarms intermit-

See “Cleaning” in the

 

tently or when residents

MAINTENANCE AND

 

are cooking, taking

CLEANING section

 

showers, etc.

 

2. Hire an electrician to

 

 

 

 

 

 

move smoke alarm to

 

 

 

a new location. See

 

 

 

SMOKE ALARM

 

 

 

PLACEMENT

 

 

 

 

Interconnected smoke

Press and hold test

 

alarms do not sound when

button for at least

 

system is tested.

 

three seconds after

 

 

 

the first unit sounds.

 

 

 

 

The alarm sounds different

The alarm is operating cor-

 

than I’m used to. It starts and

rectly. This alarm features

 

stops.

 

the internationally recog-

 

 

 

nized horn signal for evacu-

 

 

 

ation. The horn pattern is 3

 

 

 

short beeps followed by a

 

 

 

2 second pause and then

 

 

 

repeats.

 

 

 

 

REPLACE OR RETURN THE ALARM IF THE PUSH-TO-TEST FUNCTION DOES NOT OPERATE PROPERLY AFTER FOLLOWING THE PROCEDURES OUTLINED ABOVE (see REPAIR on page 6).

7

Image 7
Contents Photoelectric 110-1074C Model Fpad Smoke Alarm FeaturesSmoke Alarm Placement Important Smoke Alarm Placement and Exception Information This Smoke Alarm HOW to InstallRED and Green LED Indicators Interconnecting Smoke AlarmsTest all smoke alarms weekly by doing the following Invensys Controls Americas Practice Fire SafetyIng action TroubleshootingTo quiet an unwanted alarm. This will What to do in Case of a FireYear Limited Smoke Alarm Warranty Warranty Information