Firex E and PB, C owner manual Warranty Information, Year Limited Smoke Alarm Warranty

Page 7

WARRANTY INFORMATION

5-YEAR LIMITED SMOKE ALARM WARRANTY AND

10-YEAR LIMITED ULTRALIFE U9VL-J LITHIUM BATTERY WARRANTY (WHEN SOLD WITH INVENSYS CONTROLS AMERICAS SMOKE ALARM)

Invensys Controls Americas warrants to the original consumer purchaser each new smoke alarm to be free from defects in material and workmanship under normal use and service for a period of five (5) years from the date of purchase. For Invensys Controls Americas smoke alarms sold with an Ultralife U9VL-J 9-volt battery, Invensys Controls Americas warrants to the original consumer purchaser each new Ultralife U9VL-J 9-volt battery to be free from defects in material and workmanship under normal use and service for a period of ten (10) years from the date of purchase. Invensys Controls Americas agrees to repair or replace, at its option, any defective smoke alarm or Ultralife U9VL-J 9-volt battery (when sold with Invensys Controls Americas smoke alarm) provided that it is returned with postage prepaid and with proof of purchase date to Invensys Controls Americas. This warranty does not cover damage resulting from accident, misuse or abuse or lack of reasonable care of the product. This warranty is in lieu of all other express warranties, obligations or liabilities. THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO A PERIOD OF FIVE (5) YEARS FOR THE SMOKE ALARM AND TEN (10) YEARS FOR THE ULTRALIFE LITHIUM U9VL-J 9-VOLT BATTERY (WHEN SOLD WITH INVENSYS CONTROLS AMERICAS SMOKE ALARM) FROM PURCHASE DATE. Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you. IN NO CASE SHALL INVENSYS CONTROLS AMERICAS BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED, WHATSOEVER, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY ITS NEGLIGENCE OR FAULT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other legal rights which vary from state to state.

This smoke alarm’s manufacture and distribution are licensed by the U.S. Nuclear Regulatory Commission.

This product meets all the requirements of U.L. Standard 217.

191 E. North Avenue

Carol Stream, Illinois 60188 USA www.invensyscontrols.com ©2006 Invensys Controls

7

110-631F

Cut along dotted line

Image 7
Contents Please Read and Save this Manual Important Information about Your Smoke AlarmWhat Smoke Alarms can do Where YOU should Install Your Smoke AlarmsWhere YOU should Install Your Smoke Alarms What Smoke Alarms will not doFor Example Do install a smoke alarm in every Weekly Testing of Your Smoke Alarm HOW to Install Your Smoke AlarmWhere YOU should not Install Smoke Alarms Replacing the Battery Taking Care of Your Smoke AlarmTo Replace the Battery Ultralife BATTERIES, INC Special Smoke Alarm FeaturesUsing the Tamper Resist Locking Mechanism Invensys Controls AmericasYear Limited Smoke Alarm Warranty Warranty InformationFollow Safety Rules and Prevent Hazardous Situations Smoke Alarm Safety ChecklistWhat to do if There is a Fire in Your Home

B, E and PB, C specifications

Firex is a well-known brand in the area of fire safety, and its product line includes fire extinguishers classified as B, C, E, and PB types. These extinguishers are designed to combat specific classes of fires, and understanding their features, technologies, and characteristics is vital for effective fire safety management.

Fire extinguishers classified as B are intended for use on flammable liquids such as oils, gasoline, and other solvents. They typically utilize foam, dry chemical, or carbon dioxide (CO2) agents to smother the flames, creating a barrier between the fuel and the oxygen. The foam works to create a blanket over the burning liquid, while dry chemicals interrupt the chemical reaction. This makes B-class extinguishers essential in environments like workshops, garages, and kitchens where flammable liquids are commonly present.

C-class extinguishers are specifically designed for electrical fires. As these fires involve energized electrical equipment, using water or other conductive agents can pose a severe risk of electrocution. C-class extinguishers typically contain non-conductive agents, such as CO2 or dry chemical agents, which can put out the fire without conducting electricity. They are crucial for protecting technology-heavy environments like data centers, server rooms, and industrial applications.

E-class extinguishers are intended for use on fires ignited by combustible metals, such as magnesium, sodium, and potassium. These fires behave differently from typical fires and require specialized extinguishing agents like dry powder that can effectively smother the flames. E-class extinguishers are often found in chemical plants and metal manufacturing facilities, offering vital protection for highly reactive materials.

PB extinguishers, or portable extinguishers, encompass a variety of designs that ensure ease of access and usability. These extinguishers are lightweight and compact, making them ideal for residential, commercial, and industrial settings. The key features of PB extinguishers include ergonomic handles for easy operation, simple instructions for use, and portable sizes that allow for quick deployment during emergencies.

Overall, Firex B, C, E, and PB extinguishers play critical roles in fire safety. Their specialized designs cater to specific fire types, ensuring that appropriate measures can be taken swiftly when needed. Understanding these different classes allows individuals and organizations to make informed decisions about fire safety equipment, empowering them to protect lives and property effectively. Investing in the right type of Firex extinguisher enhances readiness against potential fire hazards wherever they may occur.