This product is designed to detect products of combustion using the ionization technique. It contains

0.9microcurie of Americium 241, a radioactive material. Distributed under U.S. NRC License No. 32- 23858-01E. Manufactured in compliance with U.S. NRC safety criteria in 10 CFR 32.27. The pur- chaser is exempt from any regulatory requirements.

WARNING! DISCONNECTING OR LOSS OF A.C. POWER WILL RENDER THE SMOKE ALARM INOPERATIVE.

ELECTRICAL RATING: 120 VAC, 60HZ, 80mA maximum per alarm (maximum 80mA for originating unit with 24 devices interconnected).

IMPORTANT! READ ALL INSTRUCTIONS BEFORE INSTALLATION AND KEEP THIS MANUAL NEAR THE ALARM FOR FUTURE REFERENCE.

CONTENTS OF THIS MANUAL

1 -- RECOMMENDED LOCATIONS FOR SMOKE ALARMS

2 -- LOCATIONS TO AVOID

3 -- INSTALLATION INSTRUCTIONS

4 -- OPERATION AND TESTING

5 -- NUISANCE ALARMS

6 -- MAINTENANCE

7 -- LIMITATIONS OF SMOKE ALARMS

8 -- GOOD SAFETY HABITS

9 -- NRC INFORMATION

10 -- NFPA PROTECTION STANDARD 72

11 -- CALIFORNIA STATE FIRE MARSHAL REQUIRED INFORMATION

12 -- SERVICE AND WARRANTY

This smoke alarm uses an extremely small amount of radioactive element in the ionization chamber (see Section 9). Do not try to repair the smoke alarm yourself. Refer to the instructions in Section 12 for service.

1. RECOMMENDED LOCATIONS FOR ALARMS

Locate the first alarm in the immediate area of the bedrooms. Try to protect the exit path as the bedrooms are usually farthest from the exit. If more than one sleeping area exists, locate additional alarms in each sleeping area.

Locate additional alarms to protect any stairway as stairways act like chimneys for smoke and heat.

Locate at least one alarm on every floor level.

Locate an alarm in every bedroom.

Locate an alarm in every room where electrical appliances are operated (i.e. portable heaters or humidifiers).

Locate an alarm in every room where someone sleeps with the door closed. The closed door may prevent the alarm from waking the sleeper.

Smoke, heat, and combustion products rise to the ceiling and spread horizontally. Mounting the smoke alarm on the ceiling in the center of the room places it closest to all points in the room. Ceiling mounting is preferred in ordinary residential construction.

For mobile home installation, select locations carefully to avoid thermal barriers that may form at the ceiling. For more details, see MOBILE HOME INSTALLATION below.

When mounting an alarm on the ceiling, locate it at a minimum of 4” (10 cm) from the side wall (see Diagram A).

When mounting the alarm on the wall, use an inside wall with the top edge of the alarm at a mini- mum of 4” (10 cm) and a maximum of 12” (30.5 cm) below the ceiling (see Diagram A).

Put smoke alarms at both ends of a bedroom hallway or large room if the hallway or room is more than 30 feet (9.1 m) long.

Install Smoke Alarms on sloped, peaked or cathedral ceilings at or within 3 ft. (0.9m) of the highest point (measured horizontally). NFPA states: “Smoke alarms in rooms with ceiling slopes greater than 1 foot in 8 feet (.3 m in 2.4 m) horizontally shall be located on the high side of the room” “A row of detectors shall be spaced and located within 3 ft. (0.9 m) of the peak of the ceiling measured hori- zontally” (see diagram “C”).

Smoke Alarms for Minimum Protection

Smoke Alarms for Additional Protection Ionization Type Smoke Alarms with

“Hush” Control or Photoelectric Type

DIAGRAM “B”

ANYWHERE

IN THIS AREA

DIAGRAM “A”

3 ft3 ft

(0.9m) (0.9m)

HORIZONTAL DISTANCE

FROM PEAK

DIAGRAM “C”

MOBILE HOME INSTALLATION

Mobile homes built in the past five to seven years have been designed to be energy efficient. Install smoke alarms as recommended above (refer to RECOMMENDED LOCATIONS and Diagram A).

In mobile homes that are not well insulated compared to present standards, extreme heat or cold can be transferred from the outside to the inside through poorly insulated walls and roof. This may create a thermal barrier which can prevent the smoke from reaching an alarm mounted on the ceiling. In such units, install the smoke alarm on an inside wall with the top edge of the alarm at a minimum of 4” (10 cm) and a maximum of 12” (30.5 cm) below the ceiling (see Diagram A).

If you are not sure about the insulation in your mobile home, or if you notice that the outer walls and ceiling are either hot or cold, install the alarm on an inside wall. For minimum protection, install at least one alarm close to the bedrooms. For additional protection, see SINGLE FLOOR PLAN in Diagram B.

WARNING: TEST YOUR SMOKE ALARM OPERATION AFTER R.V. OR MOBILE HOME VEHI- CLE HAS BEEN IN STORAGE, BEFORE EACH TRIP AND AT LEAST ONCE A WEEK DURING USE.

Image 2
Contents AC1 Mobile Home Installation Recommended Locations for AlarmsContents of this Manual Wiring Instructions for A.C. Quick Connect Harness Installation InstructionsWiring Requirements Locations to AvoidMaintenance Operation and TestingNuisance Alarms Alarm RemovalWhat to do When the Alarm Sounds Limitations of Smoke AlarmsGood Safety Habits NRC InformationNfpa Required Protection Service and WarrantyFive Year Limited Warranty

440379, 1235 specifications

The Kidde 1235,440379 is an advanced fire safety solution designed to provide reliable and efficient protection against fire hazards in residential and commercial settings. This model reflects Kidde's commitment to innovation and safety, integrating state-of-the-art technology with user-friendly features.

One of the standout features of the Kidde 1235,440379 is its dual-sensor technology. This combination of ionization and photoelectric sensors enables the detector to effectively sense both fast-flaming and smoldering fires. The ionization sensor excels in detecting rapid, intense fires that produce little smoke, whereas the photoelectric sensor is sensitive to slow-burning fires that generate heavy smoke. This dual approach significantly enhances the unit's capability to provide early warnings across different fire types, ensuring that users have more time to respond in emergencies.

In addition to its advanced sensing technology, the Kidde 1235,440379 is equipped with a voice alarm feature. This audible alert is designed to communicate the type of hazard detected, allowing occupants to make informed decisions on how to react quickly. This is particularly beneficial in high-stress situations where clear information can make a critical difference.

The unit also incorporates a convenient battery backup system, ensuring continued operation even during power outages. Its easy-to-read LED indicator provides real-time status updates, showing whether the unit is functioning correctly or if maintenance is required. Additionally, the Kidde 1235,440379 is designed with a user-friendly test/reset button, enabling users to easily check the functionality of the unit.

Installation of the Kidde 1235,440379 is straightforward, making it accessible for homeowners and property managers alike. The detector can be mounted on walls or ceilings, and comes with all necessary hardware. Its modern design and compact size ensure it blends seamlessly into any environment without being obtrusive.

Furthermore, the Kidde 1235,440379 conforms to stringent safety and environmental standards, assuring users of its reliability and performance. With its comprehensive features, advanced sensing technologies, and user-focused design, the Kidde 1235,440379 stands out as a top choice for anyone seeking enhanced fire safety for their home or business. Investing in this smoke detector is a proactive step towards ensuring the safety and well-being of all occupants, reflecting a commitment to comprehensive fire protection strategies.