120V AC Wire-In Smoke Alarm

Model i4618

Slide Load Front Battery Door

 

 

 

Architectural and Engineering

 

Installation of Smoke Alarm

Specifications

 

 

The smoke alarm should be installed to comply with all local codes having jurisdiction in your area,

 

 

Article 760 of the National Electric Code, and NFPA 72. Make certain all alarms are wired to a single,

The smoke alarm shall be Kidde Model i4618 or approved equal. It

 

 

continuous (non-switched) power line, which is not protected by a ground fault interrupter. A maxi-

shall be powered by a 120VAC, 60Hz source along with a 9V battery back-

 

mum of 1000 ft. of wire can be used in the interconnect system. Use standard UL listed household

up. The unit shall incorporate an ionization sensor with nominal sensitivity

 

wire as required by code.

FUSE OR CIRCUIT BREAKER

 

 

of 0.50 to .92%/ft. The temperature operating range shall be between 40°F

 

 

L

 

 

 

 

N

 

 

and 100°F (4°C and 38°C) and the humidity operating range shall be up to

 

 

 

 

 

 

 

 

 

 

 

85% relative humidity.

 

 

 

 

BLACK

RED

 

The smoke alarm can be installed on any standard single gang electri-

 

 

 

 

 

 

 

WHITE

 

 

cal box, up to a 4” octagon junction box. The electrical connection (to the

 

 

 

 

 

 

alarm) shall be made with a plug-in connector. A maximum of 24 Kidde

 

 

 

First

Additional

devices can be interconnected in a multiple station arrangement. The

 

 

 

 

 

 

Alarm

Alarms

 

interconnect system must not exceed the NFPA (National Fire Protection

 

Technical Specifications

Association) limit of 18 initiating devices, of which 12 can be smoke alarms.

With 18 initiating devices (Smoke, heat, CO, etc), interconnected, it is still

 

possible to interconnect 6 strobe lights and/or relay modules. The alarm

 

Model:

 

i4618

 

 

shall provide optional tamper resistance that deters removal of the unit

 

 

 

 

 

 

 

 

 

 

from the wall or ceiling. No additional pieces shall be required to activate

 

UPC:

 

0-47871-07581-2

 

this feature.

 

 

 

Power Source:

120VAC (80mA Max)

The alarm shall include an easy access battery compartment that is

 

opened and closed by sliding the battery door. The 9V battery carrier will

 

Sensor:

 

Ionization

 

ensure proper battery backup protection by not allowing the battery door

 

 

 

 

 

 

 

 

 

to close if the battery is placed in the unit incorrectly or if a battery is not

 

Audio Alarm:

85dB at 10ft

 

present.

 

 

 

Temperature Range:

40˚F (4.4˚C) to 100˚F (37.8˚C)

The unit shall include a piezoelectric horn that is rated at 85 decibels

 

at 10 feet. The unit shall include the Smart HushTM feature that silences the

 

Humidity Range:

Up to 85% relative humidity (RH)

unit for approximately 8 minutes if a nuisance condition occurs.

 

 

 

 

 

 

 

The unit shall incorporate red and green LED indicators. The green

 

Size:

 

5.6” in diameter x 1.8” depth

LED (when illuminated) indicates the presence of AC power. The red LED

 

Weight:

.5lbs

 

 

(located under the TEST/Hush button) has four modes of operation:

 

 

 

Standby Condition: The red LED will flash every 30-40 seconds to indi-

Interconnects:

Up to 24 Kidde devices

cate that the smoke alarm is operating properly. Alarm Condition: When

 

 

 

 

 

 

 

the alarm senses products of combustion and goes into alarm the red LED

 

LED:

 

Green, receiving ac power

will flash one flash per second. The flashing LED and pulsating alarm will

 

 

 

Red, 4 modes of operation

continue until the air is cleared. When units are interconnected, only the red

 

 

LED of the alarm that senses the smoke or is being tested (the originating

 

Warranty:

5 year limited

 

unit) will flash. All other units in the interconnected system will sound an

 

 

 

 

 

 

 

 

alarm but their red LED’s will NOT flash. Alarm Memory: This smoke alarm

 

5.6”

 

 

1.8”

is equipped with an alarm memory, which provides a visual indication when

 

 

 

 

 

an alarm has been activated. The red LED will illuminate for about 1.5

 

 

 

 

 

 

seconds every 16 seconds to indicate the memory condition. Smart HushTM

 

 

 

 

 

 

Mode: The red LED will illuminate for 1.5 seconds every 8 seconds,

 

 

 

 

 

 

indicating the smoke alarm is in the Smart HushTM Mode.

 

 

 

 

 

 

The unit shall at a minimum meet the requirements of UL217, NFPA72,

 

 

 

 

 

and (chapter 11), The State of California Fire Marshall, NFPA101 (0ne and

 

 

 

 

 

 

two family dwellings), Federal Housing Authority (FHA), Housing and Urban

 

 

 

 

 

 

Development (HUD).

 

 

 

 

 

 

 

Ordering Information

 

 

 

 

 

 

Model i4618

 

 

 

 

 

 

 

 

Ordering

 

 

 

 

Dimensions

 

 

 

Number

UPC

I2F5

Pack Quantity

 

(w x d x h inches)

Weight

Skid

21007581

0-47871-07581-2

100-47871-07581-9

Cut Case (6 units)

6.63 x 13.25 x 6.25

3 lbs

1008

21007584

0-47871-07584-3

100-47871-07584-0

Bulk Pack (36 units)

13.25 x 19.5 x 19.5

18 lbs

1296

21007585

0-47871-07585-0

100-47871-07585-7

Cut Case (4 units)

7.94 x 13.38 x 11.75

2 lbs

390

21007588

0-47871-07588-1

100-47871-07588-8

Bulk Pack (4 units)

6.5 x 9 x 6.5

 

2 lbs

720

21007583

0-47871-07583-6

100-47871-07583-3

Cut Case (6 units)

6.63 x 13.25 x 6.25

3 lbs

1008

Not for sale by individual unit

1016 Corporate Park Drive Mebane NC 27302 1-800-880-6788 www.Kidde.com

Distributed by:

P/N: KL-i4618 sheet

rev. 12-2009

Image 2
Contents Description Install ConfidenceModel Technical Specifications Ordering Information

I4618 specifications

The Kidde I4618 is a compact and efficient smoke alarm designed to enhance home safety. This model stands out for its reliable performance and advanced features, making it a preferred choice for many homeowners. One of the key characteristics of the I4618 is its use of ionization sensing technology, which is effective in detecting fast-flaming fires that can occur in areas such as kitchens and living rooms.

The I4618 is equipped with a 9-volt battery backup, ensuring continuous operation during power outages. This feature provides peace of mind as it guarantees that the alarm will still function even when the main power supply is compromised. Additionally, the unit includes an end-of-life warning, which alerts users when it is time to replace the alarm. This alert is crucial, as smoke alarms have a limited lifespan and should be replaced every ten years to ensure optimal performance.

Another notable feature of the Kidde I4618 is its test/silence button. This allows users to periodically check the functionality of the alarm with a simple press. In case of false alarms, the silence feature can be activated to temporarily mute the alarm, preventing unnecessary disturbance while still maintaining safety.

The design of the I4618 is user-friendly, featuring a compact and sleek profile that can blend seamlessly into any home décor. Installation is straightforward, requiring minimal tools and time. The product comes with mounting hardware and a detailed instruction manual, enabling users to set it up quickly and easily.

Safety is further enhanced with the alarm’s loud 85-decibel alarm, which can be heard throughout the home, even in noisy environments. This high volume level ensures that occupants are alerted promptly in case of smoke detection, allowing for timely evacuation.

In conclusion, the Kidde I4618 smoke alarm is a practical and reliable safety device, equipped with essential features and technologies. Its ionization sensing capability, battery backup, end-of-life warning, and user-friendly design make it an excellent addition to any home, providing peace of mind for families everywhere. Investing in smoke alarms like the I4618 is a crucial step in fire safety preparedness, ensuring that you are always one step ahead in protecting your loved ones and property.