BRK electronic user manual Inside this Manual, Other Features of Smoke Alarms, Cat LB

Page 1

User’s Manual

Long Life Lithium Power

Smoke Alarm

Cat. 4000LB

Ionization smoke alarms are generally more effective at detecting flaming fires which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a wastebasket, or a grease fire in the kitchen.

Photoelectric smoke alarms are generally more effective at detecting smoldering fires

 

which smolder for hours before bursting into flame. Sources of these fires may include

 

cigarettes burning in couches or bedding.

Model

For maximum protection, use both types of smoke alarms on each level of your home.

4000LB

 

M06-2086-001 8/99

INSIDE THIS MANUAL

IMPORTANT! PLEASE READ CAREFULLY AND SAVE.

This user’s manual contains important information about your smoke alarm’s operation. If you are installing this smoke alarm for use by others, you must leave this manual—or a copy of it—with the end user.

THIS USER’S MANUAL HAS BEEN RESIZED TO PRINT OUT ON 8-1/2 x 11” PAGES.

BLACK page numbers reference the original printed document.

RED page numbers reference this web version.

Other Features Of Smoke Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Special Compliance Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Limitations Of Smoke Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Where To Install Smoke Alarms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Where Not To Install Smoke Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Protecting Your Family From Fire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 What To Do In Case Of Fire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Important! Read Before Installing This Smoke Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 How To Install This Smoke Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Weekly Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Regular Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 If This Smoke Alarm Goes Into Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 If This Smoke Alarm Is Not Working Properly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4/5 10-Year Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4/5

All Rights Reserved. ©1999 BRK Brands, Inc.

BRK Brands, Inc., 3901 Liberty Street Road, Aurora, IL 60504-8122

Consumer Affairs: (800) 323-9005

OTHER FEATURES OF SMOKE ALARMS

Battery (DC) operated smoke alarms: Provide protection even when electricity fails, provided the batteries are fresh and correctly installed. Units are easy to install, and do not require professional installation.

AC powered smoke alarms: Can be interconnected so if one unit senses smoke, all units alarm. They do not operate if electricity fails. Units must be installed by a qualified electrician.

AC/DC powered smoke alarms: (AC with battery back-up): Can be interconnected so if one unit senses smoke, all units alarm. They will operate if electricity fails, provided the batteries are fresh and correctly installed. Units must be installed by a qualified electrician.

Smoke alarms for the hearing impaired: Special purpose smoke alarms should be installed for the hearing impaired. They include a visual alarm and an audible alarm horn, and meet the requirements of the Americans With Disabilities Act. These units can be interconnected so if one unit senses smoke, all units alarm. They do not operate if electricity fails. Units must be installed by a qualified electrician. BRK Electronics® model 100S is an AC powered unit that has an 85 decibel alarm and a 177 candela strobe light, which flashes rapidly when the unit is in alarm.

All these units are designed to provide early warning of fires if located, installed and cared for as described in the user’s manual, and if smoke reaches them. If you are unsure which type of unit to install, refer to Chapter 2 of the National Fire Protection Association (NFPA) Standard 72 (National Fire Alarm Code) and NFPA 101 (Life Safety Code). National Fire Protection Association, One Batterymarch Park, Quincy, MA 02269-9101. Local building codes may also require specific units in new construction or in different areas of the home.

SPECIAL COMPLIANCE CONSIDERATIONS

This smoke alarm alone is not a suitable substitute for complete fire detection systems in places housing many people—like apartment buildings, condominiums, hotels, motels, dormitories, hospitals, long-term health care facilities, nursing homes, day care facilities, or group homes of any kind—even if they were once single-family homes. It is not a suitable substitute for complete fire detection systems in warehouses, industrial facilities, commercial buildings, and special-purpose non- residential buildings which require special fire detection and alarm systems. Depending on the building codes in your area, this smoke alarm may be used to provide additional protection in these facilities.

The following information applies to all four types of buildings listed below: In new construction, most building codes require the use of AC or AC/DC powered smoke alarms only. In existing construction, AC, AC/DC, or DC powered smoke alarms can be used as specified by local building codes. Refer to NFPA 72 (National Fire Alarm Code) or NFPA 101 (Life Safety Code), local building codes, or consult your Fire Department for detailed fire protection requirements in buildings not defined as “households.”

1.Single-Family Residence: Single family home, townhouse. It is recommended smoke alarms be installed on every level of the home, in every bedroom, and in each bedroom hallway.

2.Multi-Family or Mixed Occupant Residence: Apartment building, condominium. This smoke alarm is suitable for use in individual apartments or condos, provided a primary fire detection system already exists to meet fire detection requirements in common areas like lobbies, hallways, or porches. Using this smoke alarm in common areas may not provide sufficient warning to all residents or meet local fire protection ordinances/regulations.

3.Institutions: Hospitals, day care facilities, long-term health care facilities. This smoke alarm is suitable for use in individual patient sleeping/resident rooms, provided a primary fire detection system already exists to meet fire detection requirements in common areas like lobbies, hallways, or porches. Using this smoke alarm in common areas may not provide sufficient warning to all residents or meet local fire protection ordinances/regulations.

4.Hotels and Motels: Also boarding houses and dormitories. This smoke alarm is suitable for use inside individual sleeping/resident rooms, provided a primary fire detection system already exists to meet fire detection requirements in common areas like lobbies, hallways, or porches. Using this smoke alarm in common areas may not provide sufficient warning to all residents or meet local fire protection ordinances/regulations.

LIMITATIONS OF SMOKE ALARMS

Smoke alarms have played a key role in reducing deaths resulting from home fires worldwide. However, like any warning device, smoke alarms can only work if they are properly located, installed, and maintained, and if smoke reaches them. They are not foolproof.

Smoke alarms cannot work without power. Battery operated units cannot work if the batteries are missing, disconnected or dead, if the wrong type of batteries are used, or if the batteries are not installed correctly. AC units cannot work if the AC power is cut off for any reason (open fuse or circuit breaker, failure along a power line or at a power station, electrical fire that burns the electrical wires, etc.). If you are concerned about the limitations of battery or AC power, install both types of units.

Smoke alarms cannot detect fires if the smoke does not reach them. Smoke from fires in chimneys or walls, on roofs, or on the other side of closed doors may not reach the sensing chamber and set off the alarm. That is why one unit should be installed inside each bedroom or sleeping area—especially if bedroom or sleeping area doors are closed at night—and in the hallway between them.

Smoke alarms may not detect fire on another floor or area of the home. For example, a stand-alone unit on the second floor may not detect smoke from a basement fire until the fire spreads. This may not give you enough time to escape safely. That is why recommended minimum protection is at least one unit in every sleeping area, and every bedroom on every level of your home. Even with a unit on every floor, stand-alone units may not provide as much protection as interconnected units, especially if the fire starts in a remote area. Some safety experts recommend installing interconnected AC powered units with battery back-up (see “Other Features Of Smoke Alarms”) or professional fire detection systems, so if one unit senses smoke, all units alarm. Interconnected units may provide earlier warning than stand-alone units since all units alarm when one detects smoke.

1

Image 1
Contents Inside this Manual Other Features of Smoke AlarmsCat LB Where not to Install Smoke Alarms Where to Install Smoke AlarmsNfpa Standard 72 Section California State Fire MarshallIMPORTANT! Read Before Installing Smoke Alarm HOW to Install this Smoke AlarmProtecting Your Family from Fire What to do in Case of FireTo install this smoke alarm, follow these steps Weekly TestingChoosing a replacement battery Tools you will needIf Your Smoke Alarm is not Working Properly If this Smoke Alarm Goes Into AlarmYear Limited Warranty Responding To An Alarm

Smoke Alarms specifications

BRK electronic smoke alarms have long been recognized as a reliable choice for enhancing fire safety in homes and commercial spaces. These devices incorporate advanced technologies designed to detect smoke and alert occupants, helping to prevent potential disasters.

One of the most notable features of BRK smoke alarms is their dual-sensor technology. Many models use both ionization and photoelectric sensors, which together provide a more comprehensive detection system. Ionization sensors are highly responsive to fast-flaming fires, while photoelectric sensors are more effective at detecting smoldering fires. This dual approach ensures that users are alerted to a wider range of fire types, enhancing overall safety.

Another significant characteristic is the incorporation of a 9V battery backup in many BRK models. This feature ensures that the smoke alarm remains functional even during power outages, providing peace of mind. Some units are hardwired, connecting directly to the home’s electrical system, but still include battery backup for added reliability.

BRK smoke alarms also offer user-friendly features such as a hush button, allowing occupants to temporarily silence the alarm in the event of a false alarm, particularly from cooking fumes or steam. This helps to reduce nuisance alarms while ensuring that the device is still fully operational.

In addition to their reliable detection capabilities, BRK smoke alarms often come equipped with a LED indicator. This light offers visual alerts, which can be particularly beneficial for individuals with hearing impairments. Some models also feature a voice alert system, providing verbal notifications that enhance user awareness during emergencies.

Installation is straightforward, with many devices designed for either wall or ceiling mounting. The sleek and modern design of BRK smoke alarms allows them to blend seamlessly into various interior aesthetics, without compromising on functionality.

Another critical aspect of these smoke alarms is their maintenance features. Many BRK models have a self-test button, allowing users to easily check the operational status of the unit, ensuring that it is always ready to perform when needed. Regular maintenance of smoke alarms is essential for optimal performance, and BRK encourages users to replace their units every 10 years as a safety standard.

Overall, BRK electronic smoke alarms combine advanced technology, user-friendly features, and reliable performance, making them an essential component of home and business fire safety plans. With their commitment to quality and safety, BRK continues to be a trusted choice for smoke detection solutions.