Hearth and Home Technologies ODGO324-IPI-LP Design and Installation Considerations

Page 3

WARNING

Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or the gas supplier.

CAUTION

Sharp Edges

Wear protective gloves and safety glasses during installation.

A.Design and Installation Considerations

WARNING

HOT! DO NOT TOUCH.

SEVERE BURNS MAY RESULT.

CLOTHING IGNITION MAY RESULT.

Glass and other surfaces are hot during operation and cool down.

Keep children away.

CAREFULLY SUPERVISE children in same room as appliance.

Alert children and adults to hazards of high temperatures.

Keep clothing, furniture, draperies and other combustibles away.

The Gas Log Hearth Kit consists of the following:

- Review proper placement of logs,lava rock.

Log Set

Check the wiring.

Burner Pan/Grate Assembly

- Ensure there are no gas leaks.

Lava Rock

- Ensure the flow of combustion and ventilation air is not

Damper Stop

obstructed (front grilles and vent caps).

B. Tools and Supplies Needed

• Before installing into a solid fuel burning fireplace, the

Tools and supplies normally required for installation:

chimney and firebox should be inspected and cleaned to

 

Pliers

remove soot, creosote, ashes, paint, bird nests etc.

 

• Annual examination of the chimney must be performed

 

Phillips screwdriver

 

by a qualified agency to ensure proper ventilation of flue

 

Tape measure

 

gases created by this appliance.

 

Crescent wrenches

 

• Have the chimney and adjacent structure inspected

 

Gas shutoff valve

 

and cleaned by qualified professionals. Hearth & Home

 

Non-corrosive leak check solution

 

Technologies recommends that NFI or CSIA certified

 

3/4 in. wrench, 7/16 in. wrench

 

professionals, or technicians under the direction of certified

 

 

 

C. Important!

professionals, conduct a minimum of an NFPA 211 Level 2

inspection of the chimney.

• Do not remove any of the attached metal plates, which

• Replace component parts of the chimney and fireplace as

 

contain important safety and operating information.

specified by the professionals.

• Keep the appliance area clear and free of all combustible

• Ensure all joints are properly engaged and the chimney

 

materials, gasoline and other flammable vapors and

is properly secured.

 

liquids.

• Do not allow fans to blow directly into the fireplace. Avoid

• Any safety screen or guard removed during servicing must

any drafts that alter burner flame pattern.

 

be replaced before operation.

• Do not use a blower insert, heat exchanger insert or other

A qualified service technician must perform installation

accessories not approved for use with this appliance.

 

and repair. The appliance should be inspected and cleaned

• This appliance must have a screen in place while the

 

annually by a qualified service technician. More frequent

appliance is in operation and, unless other provisions for

 

cleaning may be required due to excessive lint, dust, pet

combustion air are provided, the screen shall have an

 

hair, etc. It is imperative that the control compartments,

opening for introduction of combustion air.

 

burners and air passageways are unobstructed during

• Solid fuels shall not be burned in a fireplace where a

 

operation.

 

decorative appliance is installed.

 

WARNING

• If glass doors are present, the glass doors must be fully

 

opened while appliance is in operation.

Fire Risk

Exhaust Fumes Risk

Do NOT use this appliance as a “vent- free” heater.

The flue must be permanently open according to Tables 1 and 2.

Hearth & Home Technologies • Grand Oak Gas Log Sets • 4004-320 2/2011

Image 3
Contents What to do if you smell gas Outdoor Burner and Log SetCommonwealth of Massachusetts Listing Label Information/Location CongratulationsFire Risk Exhaust Fumes Risk Design and Installation ConsiderationsQualified service technician must perform installation Tools and Supplies NeededAppliance Certification Gas Supply ConnectionGas Pressure For Masonary Built Fireplaces For Minimum Fireplace DimensionsInspect the Appliance and Components For Factory Built FireplacesFire Risk Explosion Risk Personal Injury Risk Lava Rock InstallationDamper Stop Installation Instructions Inspect the Venting SystemDo not allow soot to build up on the logs Cleaning and Maintenance InstructionsGas Valve Lighting Instructions IPI Pilot Valve IPIFequently Asked Questions What sort of maintenance do gas logs require?GO324 Grand Oak Series Logs GO324 Grand Oak Series Log Placement Instructions ODGO324 IPI Valve Assembly Odgo Replacement PartsQty Description of PartWarranty Page O is not C a R D