Baxi Potterton 105 HE Clearances and Check List, Clearances around the Boiler, Figs

Page 10

5mm Min

Fig. 20

450mm

4.0 Clearances and Check List

 

 

 

 

20mm/5mm Min

 

 

 

 

 

 

 

 

 

See * NOTE:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.1

 

Clearances around the Boiler

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Figs. 20 & 21)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. The minimum clear spaces needed around the boiler

 

 

 

 

 

 

 

 

 

 

 

 

 

200mm

Min

 

measured from the casing are as follows:

 

 

 

 

 

 

 

 

 

Top

-

200mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bottom

-

200mm

 

 

 

 

 

 

 

 

 

 

Left Side

-

5mm

 

 

 

 

 

 

 

 

 

 

Right Side

-

20mm/5mm

 

 

 

 

 

 

 

 

 

 

Front

-

5mm

(In Operation)

-450mm (For Servicing)

* NOTE: The boiler can be operated with a clearance of 5mm at the right. This is also sufficient for routine maintenance. However a clearance of 20mm is required if it is necessary to remove the secondary

 

 

 

 

 

heat exchanger. This should be considered when

 

 

780mm

 

 

 

 

 

 

siting the appliance and in the event of any subsequent

 

 

 

 

 

 

 

 

 

 

 

 

alteration in the area of installation.

 

 

 

 

 

 

 

 

 

 

 

 

 

2. These areas must not be obstructed in any way, and

 

 

 

 

 

 

must be maintained during the regular operation of the

 

 

 

 

 

 

boiler and for routine maintenance. Blocking the

 

 

 

 

 

 

clearance spaces may result in the boiler overheating

 

 

 

 

 

 

and damage may occur.

 

 

 

 

 

 

3. The gas burning compartment of your boiler is

 

 

 

 

 

 

 

 

 

 

 

 

completely sealed from the room in which it is fitted.

 

 

 

 

 

 

 

200mm

Min

 

Products from the combustion of gas are vented to the

 

 

 

 

 

 

outside through the flue terminal which must be kept

 

 

 

 

 

 

free from obstruction as this would interfere with the

 

 

 

 

 

 

correct operation of the boiler.

 

 

 

 

 

 

4. The boiler may be installed in a cupboard if these

 

 

 

 

 

 

minimum clearances are kept. The compartment should

 

 

 

 

 

 

be large enough to house the boiler and ancillary

 

 

 

 

 

 

equipment only.

 

 

 

 

 

 

5. IT SHOULD NOT BE USED AS A STORAGE

 

 

 

 

 

 

CUPBOARD.

 

 

 

 

 

 

 

 

4.2 Check List

1. If a fault develops, or is suspected, call your installer or Service Engineer as soon as possible.

450mm Min

For Servicing

Purposes

5mm Min

In Operation

Fig. 21

2. Go through the following check list before you make contact.

a) Is the electricity supply on ?

b) Is the selector switch on (giving a green “Power ON” neon) and set for both Central Heating and Domestic Hot Water ?

c) Is the red “Flame Failure” neon lit ? Turn the On/Off/Reset selector fully anti-clockwise.

d) Is the gas supply on ?

e) Is the mains water supply turned on ? f) Is the system pressure correct ?

g) Are the boiler temperature controls set high enough ? h) Is the time clock (if fitted) calling for central heating ? i) Is the room thermostat (if fitted) set high enough ? j) Are the radiator valves open ?

10© Baxi Heating UK Ltd 2007

Image 10
Contents Baxi Combi 105 HE BS-EN ISO 9001 Accredited Company Legislation Important Installation, Commissioning, Service & RepairBenchmark Commissioning Checklist Codes of Practice, most recent version should be usedServicing your Appliance An EmergencyCase of gas leaks Electricity SupplyIntroduction IntroductionFacia Panel Operating the Boiler ResetOperating the Boiler Flame Failure Reset Temperature ControlSafety Thermostats Air Flow Monitor Pump Fault or Low PressureSensor Fault Pump ProtectionCentral Heating System Pressure Frost Protection ModeTo Shut Off the Boiler Figs Clearances and Check ListClearances around the Boiler Check ListCare of the Boiler Cleaning the OutercaseSpare Parts Warranty & Service Please complete the boxes below
Related manuals
Manual 12 pages 23.05 Kb

105 HE specifications

The Baxi Potterton 105 HE is a popular choice for homeowners seeking an efficient and reliable heating solution. Known for its innovative technology and user-friendly features, this boiler is designed to meet the demands of any household while ensuring comfort and energy efficiency.

One of the standout features of the Baxi Potterton 105 HE is its impressive energy efficiency rating. With a high Seasonal Efficiency of Heating (SEDBUK) rating, it can significantly reduce energy bills by maximizing heat output while minimizing fuel consumption. This is particularly important for environmentally conscious consumers looking to decrease their carbon footprint.

The boiler employs a compact design, making it suitable for various installation scenarios, including tight spaces. Weighing relatively light and equipped with rear flue option, it facilitates easier placement in kitchens, utility rooms, or lofts without requiring significant alterations to existing layouts.

The Baxi Potterton 105 HE boasts a reliable and user-friendly digital display, allowing users to monitor their heating system effortlessly. It features a built-in time clock that can be programmed for heating schedules, providing flexibility and ensuring warmth when needed most. Additionally, a wide range of system control options is available, enabling integration with smart thermostats for even greater control over home heating.

This boiler is equipped with a modulating burner, which adjusts the heat output based on the heating demand. This technology enhances comfort by maintaining consistent temperatures and reducing the risk of overheating or underheating rooms. It further supports efficiency by using only the necessary amount of fuel during operation.

Maintenance is simplified with the Baxi Potterton 105 HE, which is designed with easy access points for servicing. The inclusion of fewer components in its construction helps minimize the likelihood of mechanical failures, promoting reliability and longevity.

Safety features are also paramount in the design of the Baxi Potterton 105 HE. It incorporates advanced diagnostics and safety cut-offs to protect both the appliance and the household from potential hazards.

Overall, the Baxi Potterton 105 HE combines energy efficiency, modern technology, and practical design to deliver a top-tier heating solution for today's homes. Its well-rounded features make it a wise investment for anyone looking to enhance their home comfort while remaining mindful of energy consumption.