Baxi Potterton 30 HE warranty Fault Indication

Page 6

NOTE: The neons annotated have a dual function, indicating the temperature of the central heating water when constantly illuminated or begin to flash to indicate a fault.

 

 

Air Flow

 

 

Pump/Low

 

 

Monitor Neon

 

 

Pressure Neon

Safety Thermostat

 

 

Sensor Fault

Neon

 

 

 

 

Neons

Flame

 

 

 

 

 

Failure

 

 

 

Neon

 

 

 

30° 40° 50° 60° 70°

80°

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 1

Reset

Fig. 2

Reset

Fig. 3

3.0Fault Indication

3.1Air Flow Monitor

1.The boiler is fitted with an air pressure sensing device. This monitors the flue system.

2.If the ( ) neon illuminates it indicates that the flue or flue terminal is blocked or obstructed in some way, or that

there is an internal fault. If there is no external blockage of the flue terminal that can be easily removed contact your Installer or Service Engineer (Fig. 1).

3.2Pump Fault or Low Pressure

1.The neon ( ) will illuminate if the circulating pump is faulty or the system pressure drops below the minimum

requirement (Fig. 1).

2.Check the pressure gauge as described on page 8. If the pressure is in the normal range, a pump fault is indicated. Contact your Installer or Service Engineer to determine the nature of the fault.

3.3Sensor Fault

1.When either of the ( ) or ( ) neons is illuminated a fault on one of the temperature sensors is indicated (Fig. 1).

Contact your Installer or Service Engineer.

3.4Pump Protection

1.With the selector switch in the on position (Fig. 2) the pump will automatically operate for 1 minute in every 24 hours to prevent sticking.

3.5Safety Thermostat

1.Your Potterton Performa HE is fitted with an additional safety devices, which shut down the boiler in the event of the

system, boiler or flue overheating. The safety thermostat neon ( ) will light in this instance (Fig. 1).

3.6Flame Failure

1.The red flame failure neon () will illuminate in the event of the burner failing to light, when incomplete lighting of the

burner occurs or blockage of the condensate drain (Fig. 1).

3.7To Reset the Safety Thermostat or Flame Failure

1.To reset: Turn the selector fully anti-clockwise against the spring pressure to the ‘Reset’ position for at least two seconds and release (Fig. 3).

2.If after turning the selector to the ‘Reset’ position the boiler does not relight or the safety thermostat or flame failure operates repeatedly, causing boiler shutdown, a fault is indicated. Your Installer or Service Engineer should be contacted as soon as possible.

6© Baxi Heating UK Ltd 2009

Image 6
Contents User’ Guide Contents 0086Quick Reference Guide OFF Position Central Heating & Hot Water Domestic Hot WaterTroubleshooting Is the Timer on and calling for heat ? Is the Room Thermostat ifFault Indication System Pressure & Temperature Temperature ControlCentral Heating System Pressure Clearances Care of the Boiler OFF PositionTo Shut Off the Boiler Fig Installation, Commissioning, Service & Repair Benchmark Commissioning ChecklistLegislation Faulty boiler EmergencyIf you smell gas Warranty & Service Please complete the boxes below
Related manuals
Manual 56 pages 38.59 Kb

30 HE specifications

The Baxi Potterton 30 HE is a popular choice among homeowners seeking an efficient and reliable boiler solution. Recognized for its compact design and advanced technologies, this boiler is ideal for various residential heating needs.

One of the standout features of the Baxi Potterton 30 HE is its high efficiency rating, which ensures lower energy consumption and reduced utility bills. With an impressive efficiency of up to 90%, this boiler operates at a much higher capacity compared to older models, making it both environmentally friendly and cost-effective. The 30 HE is particularly well-suited for medium to larger homes with a higher demand for hot water.

The Baxi Potterton 30 HE incorporates a range of innovative technologies aimed at enhancing performance and reliability. The automatic modulation function adjusts the boiler's output according to demand, ensuring that it only works as hard as necessary. This not only prolongs the lifespan of the unit but also maximizes comfort levels in the home.

Another feature of the 30 HE is its low noise operation. This boiler has been specifically designed to minimize sound, allowing it to operate quietly in the background without disturbing daily activities. This makes it an ideal choice for homes where noise can be a concern, particularly in open-plan living spaces.

The compact dimensions of the Baxi Potterton 30 HE make it easy to install in various locations, whether it be in a kitchen, utility room, or even a loft space. Its lightweight construction further simplifies the installation process, saving both time and labor costs.

In terms of user-friendliness, the boiler is equipped with an intuitive control panel that allows homeowners to easily adjust settings and monitor performance. This user-centric design ensures that even those who may not be technically inclined can manage their heating requirements with ease.

Safety features are also a priority in the design of the Baxi Potterton 30 HE. It includes built-in safety mechanisms such as frost protection and a burner pressure monitoring system, which work to prevent overheating and ensure optimal operation.

Overall, the Baxi Potterton 30 HE is an efficient, reliable, and user-friendly boiler that meets the heating demands of modern homes. Its blend of advanced technologies, compact size, and focus on safety make it a standout choice for homeowners seeking a high-performance heating solution.