Trane XT500C manual Cool is lit, but no warm or

Page 62

Troubleshooting Guide (continued).

Symptom

Possible Cause

 

 

Action

 

 

 

 

 

 

System on indicator

Heating/cooling equipment turns on

 

Wait a minute after seeing the flame or snowflake and then

 

(flame=heat, snowflake=

the fan when the equipment has

 

check the registers.

 

cool) is lit, but no warm or

reached the setpoint.

 

 

 

 

cool air is coming from

 

 

 

 

 

the registers.

 

 

 

 

 

 

 

 

 

 

System on indicator

Filter expired.

 

Refer to the Filter Indication section.

 

reads Filter and backlight

 

 

 

 

 

is flashing.

 

 

 

 

 

 

 

 

 

 

 

Outdoor temperature not

Filter expired.

 

Press

twice for outdoor temperature when filter

 

displayed or is incorrect.

 

 

expiration shows on display.

 

 

 

 

Refer to the Filter Indication section.

 

 

Installer did not activate this option.

 

Contact installer or service technician.

 

 

Outdoor sensor is connected

 

 

 

 

 

incorrectly.

 

 

 

 

 

 

 

 

 

LED is lit.

System switch is set to Em. Heat.

 

Move switch to Heat or Auto

 

 

Compressor failure.

 

Contact service technician.

 

 

 

 

 

 

 

 

 

 

 

Pub. No. 22-5128-02

 

62

 

69-1216

 

Image 62
Contents XT500C Deluxe Programmable Heat Pump Thermostat Table of Contents Programming Your Thermostat Pub. No Customizing Your Thermostat Program Options Set-Up by Your Trane DealerPub. No Getting around the Keyboard SET Wake Times SET Sleep Times Temperatures Emergency Heat Auxiliary HeatFeatures Features Youõll Want to Know More about Comfort-R Comfort Enhancement SystemRecovery indication shown in example above Adaptive Intelligent Recovery ControlYour Thermostat Senses Temperature More Like You Do Optimum Comfort Energy Savings Solution Pub. No 69-1216 Changing Temperature Setting Until the Next Schedule Period Neat Stuff Youõll be Using OftenSetting Temporary Temperatures Temporary Changing Temperature Setting Indefinitely Press Hold Temp onceCool Press Increase or Decrease to adjust temperature settings Vacation Mode Hold for Fri Days Heat Wake M17039 Pressed the wrong key? Want to start over? Displaying Outdoor Temperature Information KeyDisplaying Current Settings Filter Indication Setting or Resetting Filter Indication Timer Press Filter to enter the Filter modeRun Program Clock Setting Current Day and TimeProgramming Your Thermostat Press Set Current Day/Time Press Time or Time until the current time displays Setting System and Fan Set SystemDay Program and Operation Day Preprogrammed ScheduleDay Preprogrammed Schedule Word About Power Outages Customizing Your Own 7-Day ScheduleInstructions Your 7-Day Schedule An Extra 7-Day Schedule Programming the First Day Press WakeM17057 M17059 Set Program Leave Return Sleep Press Wake, Leave, Return or Sleep to enter program mode Copying a DayPress Copy Copy Run Program Press Leave, Return or Sleep to enter program mode Clearing Schedule PeriodFor 7-Day Operation, press Day until Run Program Hour Program and Operation Hour Preprogrammed ScheduleCustomizing Your Own 24-Hour Schedule Programming Your 24-Hour Schedule An Extra 24-Hour SchedulePress Wake M17071 MonTueWedThuFriSatSun Cool Wake Fan M17073 Constant Temperature Setpoint Programming Setting Temperature and Fan OperationSetting Heat Setting Cool Troubleshooting Guide Symptom Possible Cause ActionTroubleshooting Guide Cool is lit, but no warm or Definitions Adaptive Intelligent Recoveryª ModesConventional Recovery Conventional Recovery Modes Setpoint Preprogrammed SchedulePeriod SystemIndex DefinitionsLimited Warranty Low Voltage Room ThermostatsCustomer Assistance