Honeywell 1EN2R-9005 0406R3-NE Miscellaneous, Knob Scale range Low limit stop High limit stop

Page 19

Miscellaneous

Description

Ordernumber

Packing qty (pcs)

Knob assembly

45.900.427-002

200

Scale range: 110 ... 230°F, high limit stop: 180°F

 

 

Knob assembly

45.900.427-003

200

Scale range: 40 ... 110°C, high limit stop: 82°C

 

 

Strap set for L6190 surface mounted aqustat

45.900.443-001

50

Strap length: 2000 mm

 

 

 

Key

Description

 

 

Part number

 

number

 

 

 

 

 

 

 

 

 

 

1

Fixing screw for front covers of single and dual aquastats

45.002.700-001

 

 

 

 

 

 

2

Knob

 

 

 

 

 

Scale range

Low limit stop

High limit stop

 

 

 

40

... 110°C

-

-

45.002.823-001

 

 

 

 

 

 

 

 

 

70

... 140°C

-

-

45.002.823-002

 

 

25

... 95°C

-

-

45.002.823-003

 

 

 

 

 

 

 

 

 

40

... 110°C

-

95°C

45.002.823-004

 

 

 

 

 

 

 

 

 

70

... 140°C

95°C

-

45.002.823-005

 

 

40

... 110°C

50°C

95°C

45.002.823-006

 

 

 

 

 

 

 

 

 

25

... 95°C

-

82°C

45.002.823-007

 

 

 

 

 

 

 

 

 

40

... 110°C

-

100°C

45.002.823-008

 

 

25

... 95°C

-

60°C

45.002.823-010

 

 

 

 

 

 

 

 

 

70

... 140°C

-

95°C

45.002.823-011

 

 

 

 

 

 

 

 

 

25

... 95°C

60°C

80°C

45.002.823-013

 

 

1 ... 7 (40 ... 110°C)

-

85°C

45.002.823-014

 

 

 

 

 

 

 

 

 

50

... 95°C

-

82°C

45.002.823-015

 

 

 

 

 

 

 

 

 

40

... 110°C

-

82°C

45.002.823-017

 

 

25

... 95°C

40°C

80°C

45.002.823-019

 

 

 

 

 

 

 

 

 

80

... 100°F

-

-

45.004.213-001

 

 

 

 

 

 

 

 

110 ... 230°F

-

-

45.004.213-002

 

 

160 ... 280°F

-

-

45.004.213-003

 

 

 

 

 

 

 

 

110 ... 230°F

-

200°F

45.004.213-004

 

 

 

 

 

 

 

 

110 ... 230°F

-

180°F

45.004.213-005

 

3

Cover for single Aquastat

 

45.002.547-002

 

4

Screw

 

 

45.000.219-015

 

 

 

 

 

 

5

Wire clamp

 

 

45.002.797-001

 

6

Conduit box

 

 

45.002.540-001

 

7

Push in plug

 

 

45.002.802-001

 

 

 

 

 

 

 

19

EN2R-9005 0406R3-NE

Image 19 Contents
Application ContentsAquastats thermostats Micro SwitchManual or tool reset Adjustable differentialDescription OVERVIEW/SELECTION Guide Features Application L4188 L6188 Single Aquastat Direct ImmersionOrdering information Specifications L4189A Controller 95C Capilliary length Electrical connectionsApplication and Ordering Information L6190 Single Aquastat Surface MountingInternal schematic L6190 Terminal data Ordering information L4191 L4191 L6191 Dual Aquastat Direct ImmersionControl Limit Spst Spst Control Limit 1 C Spst Spdt Control Limit 1 2 CSpdt Ordering information L6188ALimit stops Temperature rangeBreaks on temperature rise DifferentialPerformance All aquastats have the following common parts ConstructionSurface mounted Aquastat needs the following extra parts Single well assembly Accessories and Spare PartsDual well assembly Knob Scale range Low limit stop High limit stop MiscellaneousStandards Standards and ApprovalsApprovals Ordering Information When ordering specifyHome and Building Control Combustion Control Center Europe