Carrier 53DFS250-FS owner manual Hoi

Page 6

HOLIDAY MODE -- This feature forces the thermo-

stat into Unoccupied for a preset duration, up to

99 days. The Holiday setup display is entered as follows:

Press the Mode button. While holding Mode, press the Up button for 2 seconds to enter the time period programming setup

MODE O

4,

The first step on the display prompts for maximum number of

Occupied periods ignore this prompt and press the Override button.

HOI

When active tile display counts down remaining days blinking.

When entering the Auto mode from Cool, the Heat and Cool set points will remain spread apart by the

amount that they were adjusted, prior to entering Auto.

For example: If the Cool set point was set to 80 while in the Cool mode and the Heat set point was adjusted to 70 while in the Heat mode, upon enter- ing the Auto mode the Heat and Cool set points would be 80 and 70. Both set points would then move up and down together, (in this example

spread by 10 degrees), by pressing the up or down buttons.

To move the Heat and Cool set points closer together, enter the Cool or Heat mode by pressing the Mode button, then adjust the set point(s) closer

A

appears

LIUnoccupied also

together. Heat is limited to how close it can come to Cool by Step 6, page 4.

Press the Up or Down buttons to select the number of days ?Y the thermostat will be in Holiday mode. O = Off. To exit Holiday

setup, press the Mode button.

The thermostat will enter the Holiday mode when the clock crosses midnight.

During Holiday mode Unoccupied set points are enforced.

REMOTE SENSORS (Optional Accessory) -- When connected to terminals RS+5, RS, and GND

on the back of the thermostat, the thermostat will read the temperature from the Remote Sensor and ignore the temperature sensor inside the thermo- stat. The thermostat automatically recognizes when a Remote Sensor is connected. When reading the temperature from the remote, the degree icon above the room temperature blinks once a second.

The Override button is active during Holiday mode. It will override to Occupied 1 settings up to 4 hours then return to Holiday mode. The Dry Contact Switch is ignored.

The thermostat will exit Holiday mode at midnight of the final programmed day. To terminate Holiday

immediately, enter the Holiday setup screen and select 0.

Optionamm,,li_mm

Remote Sensor

Optional Sensor

The Override button on the Remote Sensor

works slightly different than the Override button

on the front panel. Each

press of the 'External' Override button adds

2 hours to the override timer, if the timer was

SOFT START -- This feature is utilized in multiple thermostat installations controlled by the Dry Con- tact terminals. Assigning a unique Soft Start num- ber to each thermostat will stagger the turn on

times, even though the Dry Contact closes for all the thermostats connected at the same time. Each

Soft Start number represents a multiple of 30 sec- onds from the Dry Contact closure. For example,

1 = turn on 30 seconds after Dry Contact closure, 2 = turn on 60 seconds after closure, 3 = turn on 90 seconds after closure, and so on. See page 5, Step 14, to configure the thermostat for Soft Start.

DUAL SETPOINT BEHAVIOR -- The adjustable set point range is: 35 to 99 degrees in Fahrenheit and 7 to 35 degrees in Centigrade. When in the modes Heat or Cool, this adjustable range is unhampered.

When adjusting any Auto mode, including program- ming Occupied and Unoccupied periods, the ther- mostat will not allow the Heat set point to get closer to the Cool set point than the value programmed as the minimum difference in Step 6, page 4.

already active, the first button press will round the runtime to either 2:00 or 4:00.

Subsequent button presses will not wraparound as the Override button on the thermostat does, so the

second or greater button press will set the runtime to 4:00. The Locked feature has no effect on the

external Override button. The wired Remote Sensor is connected to the thermostat with up to 500 ft of

20 ga. or 300 ft of 18 ga. thermostat wire. See the Remote Sensor instructions for further details.

FACTORY DEFAULTS -- Before restoring factory defaults, set thermostat to OFF mode. If, for any reason it is desirable to return all stored settings back to the factory default settings, press the Mode button. While holding the Mode button in, press the Down button for 2 seconds. All icons will appear. Press and hold in the Override button until Fd appears. This resets all factory settings. To cali- brate room temperature, press the Mode button once more. At this point use the Up and Down

buttons to calibrate room temperature, if needed. Press the Mode button to return to normal

operation.

Page 6

Image 6
Contents I1€1,1Bill Advanced Setup About Features Operation WarrantyBeforeIMPORTANTproceedingFollow. Installation Instructions Front Panel Display Quick StartSelect Mode Important i Before you Begin 2i .uuOff IlL YesAdvanced Setup Minimum HEAT/COOL SET Point DifferenceHOI YlYlil 1iTILv

53DFS250-FS specifications

The Carrier 53DFS250-FS is a distinguished addition to Carrier’s lineup of commercial refrigeration units. This model is specifically designed to provide efficient and reliable cooling for various applications, making it a go-to choice for food service operators, grocery stores, and convenience stores. The 53DFS250-FS is known for its robust construction and advanced technologies that enhance its performance and energy efficiency.

One of the hallmark features of the Carrier 53DFS250-FS is its advanced refrigeration system. It utilizes a state-of-the-art compressor that ensures optimal cooling performance while minimizing energy consumption. The unit is equipped with a variable speed drive that adjusts the compressor's speed based on the cooling demand, thus enhancing energy savings and reducing operational costs.

The 53DFS250-FS also boasts an impressive capacity, making it suitable for a wide range of applications. With a cooling capacity of 250 cubic feet, this unit is designed to accommodate a significant volume of products, keeping them at safe and optimal temperatures. The refrigeration system is supported by an efficient circulating fan that evenly distributes cool air, ensuring consistent temperature across all shelves.

Durability is another critical characteristic of the Carrier 53DFS250-FS. Constructed with high-quality materials, the unit is designed to withstand the rigors of daily use in busy commercial environments. Its self-closing doors and heavy-duty hinges provide ease of access while maintaining efficiency. The interior is designed with adjustable shelving, allowing businesses to maximize their storage capabilities based on their specific needs.

In terms of technology, the Carrier 53DFS250-FS features intelligent temperature controls that provide accurate and responsive cooling management. This system allows users to set and monitor temperature levels with precision, ensuring that food items are stored under optimal conditions. Additionally, the unit is equipped with advanced diagnostics that help in monitoring performance and identifying potential issues before they escalate into significant problems.

The 53DFS250-FS is also designed with environmental sustainability in mind. It uses eco-friendly refrigerants that comply with the latest environmental regulations, ensuring that businesses can operate without compromising their commitment to sustainability.

Overall, the Carrier 53DFS250-FS is a reliable and efficient refrigeration solution that caters to the needs of various commercial applications. With its powerful performance, durability, and advanced technology, it remains a preferred choice for operators looking to enhance their refrigeration capabilities while maintaining cost-effectiveness and environmental responsibility.