Bryant P/N TSTATBBP220-LA instruction manual Daily Schedule Planner, Ð5Ð, DAY Schedule, Week

Page 5

Table 3 Ð Daily Schedule Planner

DAY

 

 

 

 

 

SCHEDULE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OF THE

 

Occupied 1

 

 

Occupied 2

 

Occupied 3

 

Unoccupied

WEEK

 

 

 

 

 

 

 

 

 

 

Start / Stop / Heat / Cool

Start / Stop / Heat / Cool

Start / Stop / Heat / Cool

Heat / Cool

 

 

 

 

 

 

 

 

 

 

 

 

Monday

/

/

/

/

/

/

/

/

/

/

 

 

 

 

 

 

 

 

 

 

 

Tuesday

/

/

/

/

/

/

/

/

/

/

 

 

 

 

 

 

 

 

 

 

 

Wednesday

/

/

/

/

/

/

/

/

/

/

 

 

 

 

 

 

 

 

 

 

 

Thursday

/

/

/

/

/

/

/

/

/

/

 

 

 

 

 

 

 

 

 

 

 

Friday

/

/

/

/

/

/

/

/

/

/

 

 

 

 

 

 

 

 

 

 

 

Saturday

/

/

/

/

/

/

/

/

/

/

 

 

 

 

 

 

 

 

 

 

 

Sunday

/

/

/

/

/

/

/

/

/

/

 

 

 

 

 

 

 

 

 

 

 

NOTE: The cooling temperature set point must be higher than the heating temperature set point. (The temperature difference may be changed in the advanced setup con®guration.)

Fig. 5 Ð Setting Occupied 1 Set Points

3.The heating set point for Occupied 1 will be displayed. Use the UP ARROW and DOWN ARROW buttons to raise or lower the heating set point until the desired temperature is shown. The range of acceptable values is 35 to 99 F (1 to 37 C). Press the Mode button to con- tinue. See Fig. 5.

4.The cooling set point for Unoccupied will be displayed. Use the UP ARROW and DOWN ARROW buttons to raise or lower the cooling set point until the desired temperature is shown. The range of acceptable values is 35 to 99 F (1 to 37 C) or ``OF'' (no unoccupied cool- ing). Press the Mode button to continue.

5.The heating set point for Unoccupied will be dis- played. Use the UP ARROW and DOWN ARROW but- tons to raise or lower the heating set point until the desired temperature is shown. The range of acceptable values is 35 to 99 F (1 to 37 C) or ``OF'' (no unoccupied heating). Press the Mode button to continue.

6.The day of the week will be shown. Use the UP ARROW and DOWN ARROW buttons to change the day of the week until the desired starting day is shown. Possible choices are M (Monday) through S (Sunday). Press the Mode button when the desired day is shown.

7.The Start Time for Occupied 1 will be displayed. Use the UP ARROW and DOWN ARROW buttons to raise or lower the time until the desired Start Time is shown. Press the Mode button to continue. See Fig. 6.

Fig. 6 Ð Start Time Display

8.The Stop Time for Occupied 1 will be displayed. Use the UP ARROW and DOWN ARROW buttons to raise or lower the time until the desired Stop Time is shown. Press the Mode button to continue.

9.The On/Off icon will be displayed. Use the UP ARROW to turn the Occupied 1 period ON for this day. Use the DOWN ARROW to turn the Occupied 1 period OFF for this day.

10.Repeat Steps 2 through 9 to program the remaining schedule for Occupied periods 2 and 3.

11.The Copy command can be used to copy the previous day's schedule if the schedules are the same. The copy command becomes available after all the occupied periods are programmed in a day. Use the UP ARROW to change the copy command to YES. Use the DOWN ARROW to change the copy command to NO. Press the Mode button when the choice has been made. See Fig. 7.

If NO was selected, the schedule will automatically change to the next day and the user must enter the oc- cupied and unoccupied schedules for that day.

NOTE: Occupied 1 schedule heating and cooling set points are the same for each day. Occupied 2 and 3 set points may be set to different values for each day of the week.

If YES was selected, the schedule will be copied to the next day. The schedule copy may be repeated until Sun- day is reached. The Sunday schedule cannot be copied to Monday.

Ð5Ð

Image 5
Contents Safety Considerations ContentsInstallation Select Thermostat Location GeneralÐ2Ð II. Install ThermostatIII. SET Clock IV. Heat Pump ConfigurationConfigure Advanced Setup VII. Program Thermostat Schedules VI. Install AccessoriesÐ5Ð Daily Schedule PlannerDAY Schedule WeekIX. Light Sensor Adjustment VIII. Calibrate Temperature SensorXI. Final Checklist Overriding the ScheduleVIII. Holiday Mode IV. Clock BackupOperation AUTO-CHANGEOVERProblem Solution TroubleshootingThermostat Troubleshooting