American Standard T050.541 installation instructions Trim Installation, Install Handles

Page 2

1 TRIM INSTALLATION

Remove PLASTER GUARD (1).

Remove HANDLE SCREW and ADAPTER (7) from rough valve.

Push CAPS (2 & 3) as shown onto CONTROL VALVES (4).

Push ESCUTCHEON (5) onto CAPS (2 & 3) and attach with (60mm) SCREWS (6) to valve.

Push COVER PLATE (7) onto CAPS (2 & 3) and snap into holes in ESCUTCHEON (5) to secure.

4

7

2

5

7

TOP

3 6

1

2 INSTALL HANDLES

Install HANDLE ADAPTER (1) onto VOLUME CONTROL SPLINE (2).

Align CROSS HANDLE (3) and push onto HANDLE ADAPTER (1). Install HANDLE SCREW (4) in CROSS HANDLE (3) and tighten with flat blade screwdriver. Insert index button (5).

Align the two splines in LEVER HANDLE (6) with the knob mount arrow (Figure 1) and push LEVER HANDLE (6) onto KNOB MOUNT (7). Install HANDLE SCREW (8) in LEVER HANDLE (6) and tighten with phillips screwdriver. Insert index button (9).

2

7

1

3

4

O

O

5

O

O

N

N

6

KNOB

MOUNTTWO SPLINES ARROW

Figure 1

7

6

8

9

3 TRANSPOSED SUPPLY PIPING OR BACK TO BACK INSTALLATION

Should the hot and cold water supply pipes have been transposed making adjustment impossible, proceed as follows:

Shut off water supply.

Remove handle and rim. (Reverse steps 1 and 2.

Remove check stops and re-install them transposed.

Important note: RED CHECK STOP is now on the right of the mixer body and the BLUE CHECK STOP is now on the left.

Turn the water supply back on and perform the temperature adjustment in step 2.

Assemble HANDLES and TRIM.

CHECK STOP

(BLUE TO RED)

CHECK STOP

(RED TO BLUE)

M968419 REV 1 . 1

Image 2
Contents Do not ROUGHING-IN DimensionsCare Instructions Transposed Supply Piping or Back to Back Installation Trim InstallationInstall Handles Temperature Adjustment SET HOT Limit StopClassic Thermostat Installation Instructions TOP 953951-0070A Central Thermostat with Volume Control HOT ROUGHING-IN the ValveCold 912647-0070A