Aprilaire 61000652C 8400 Tstat installation instructions 20F -7C, 60F 16C

Page 15

Setup & Testing

System setup instructions (continued)

System setting

Setting range, default in bold

 

 

 

16

Low Balance Pt. (8446, 8448HP, 8465, 8466HP)

20°F (–7°C)

 

System setting 05 must be enabled

1°F to 35°F (–17°C to 1°C) or “OFF” to disable

17

High Balance Pt. (8446, 8448HP, 8465, 8466HP)

60°F (16°C)

 

System setting 05 must be enabled

40°F to 80°F (4°C to 27°C) or “OFF “ to disable

 

 

 

19

Program format (8463, 8465, 8466)

0 – 5/2 program (Weekdays and Weekends)

1 – 5/1/1 program (Weekdays, Sat. and Sun.)

 

 

 

 

 

20

Change air filter

OFF

1, 3, 6, 12 months or “OFF” to disable

 

 

 

 

 

21

Change water panel**

OFF

 

Set number of months until reminder is required

1 to 12 months or “OFF” to disable

 

 

 

22

Humidifier type**

0 : Flow through type humidifier (1 reminder per season)

1 : Drain-less type humidifier (2 reminders per season)

 

 

23

Service dehumidifier

OFF

1 to 12 months or “OFF” to disable

 

 

 

 

 

24

Service HVAC

OFF

1 to 12 months or “OFF” to disable

 

 

**If humidifier type is set to Drain-less, then the first reminder is based on the system setting 21, second reminder will activate 3 months later. If humidifier type is set to Flow through, then the first reminder is based on system setting 21, second reminder will activate 12 months later.

15

61000652C 8400 Tstat Install.indd 15

10/13/09 11:09:00 AM

Image 15
Contents Safety Installation Instructions Table of contents Do not mount thermostat InstallationOutdoor temperature sensor optional For heat pump models 8446, 8448HP, 8465, 8466HP Thermostat mounting Power & Reset optionsInstallation notes Wiring terminal Wire specificationsWiring Model 8463 & 8444 Two Transformers Remove Jumper Wire Wiring Model 8465 & 8446 Two Transformers Remove Jumper Wire RC R RC R W Y G C S1 S2 O/B L W2 Y2 System setup instructions Setup & Testing SW1 Minutes Auto mode is disabledFahrenheit No offset applied3F 2C Progressive recovery is enabled1F 0.5C B energized in cooling O60F 16C 20F -7CTest steps are System test modePress and hold System test mode How to enter the system test menu PressTest steps for 8444 System Setting Display OutputTest steps for 8448HC & 8466HC Test steps for 8446 Test steps for 8448HP & 8466HP Non-Programmable models 8444, 8446 Quick Reference to controls & DisplayProgrammable models 8463, 8465 Thermostat Features All 8400 series thermostatsProgrammable models only 8463, 8465 Troubleshooting Temperature settings do not changeDisplay is blank Heating is not displayed Heating equipment is running in cool modeFan does not turn on in a call for heat Heat/cool both on at same timeSpecifications EnvironmentElectrical Thermal