GSI Outdoors PNEG-301 installation manual Bin Step Optional

Page 8

8

1. Installation

Inner Door Auger Hood (Optional)

12' (3.66 m) - 24' (7.32 m) Diameters Only

Figure 1C

Remove bolts, lock washers and nuts along each side of large square opening. Position auger shield as shown in Figure 1C and bolt to underside of top angle with bolt heads under shield. Replace bolts, lock washers and nuts along sides of opening.

Unloading grain through door opening may cause grain bin failure if not done properly. Unloading directly through the door opening should be limited to grain bins no larger than 24' (7.32 m) diameter and grain depths no greater than

18' (5.49 m).

Unloading from the door opening should be done only with use of an auger hood with the auger inserted through the opening to the center of the grain bin.

Bin Step (Optional)

Figure 1D

PNEG-301Two-Ring Door

Image 8
Contents Two-Ring Door Instructions PNEG-301Two-Ring Door Contents Two-Ring Door Installation Installation Two-Ring Door Assembly Parts List for Two-Ring Doors Bin Step Optional Installation