Gianni Industries Keyprox Plus manual Application, Single Door System, Two Door System

Page 2

Keyprox Plus

Access Control System

Application

The KeyProx Plus controller has both a RS-232 and a RS-485 interface.

Use the RS-232 interface for simple installation having a single controller and where the distance between the controller and the PC is less than 30 meters. The drawings below show typical RS-232 installations. RS-232 connection to PC - max 30m

Single Door System

RS-232 to PC

3 core

 

 

 

2 core

 

 

 

 

 

2

 

 

 

3 core

2

Doorcore

 

 

 

 

core

Sw 1

Door strike 1

 

 

 

 

 

2 core

 

 

 

 

Power supply

 

 

 

 

AC IN

12VDC 0.5A

 

 

 

 

N L

- +

 

 

 

 

 

Reader A

 

 

 

Reader B

P.B.

NO COM NC

 

 

 

 

 

 

 

 

 

Exit 1

Two Door System

 

Door strike 1

 

 

 

 

2

 

 

 

core

 

 

 

2

 

2

 

core

RS-232 to PC

core

3core

 

Door Sw 1

 

 

 

 

Reader A

 

 

 

 

 

 

 

2

 

 

 

 

 

2

core

 

 

 

 

 

 

 

 

 

 

 

core

 

2

 

 

 

 

 

core

 

 

 

Door Sw 2

 

Door strike 2

 

 

 

 

 

 

 

 

 

 

3core

2core

 

 

 

 

 

Power supply

 

 

 

AC IN

 

12VDC 0.5A

 

Reader B

 

N

L

-

+

 

 

 

 

 

 

 

 

P.B.

 

NO COM NC

 

 

 

 

 

 

 

 

Exit 1

Exit 2

GIANNI INDUSTRIES, INC.

No. 13, Zhong Sing Road, Tu-Cheng Industrial Zone, Tu-Cheng City, Taipei, Taiwan 23678

Tel: 886-2 2267 7986 / Fax: 886-2 2267 9876

E-Mail: info@gianni.com.tw

Website: gianni.tw

Gianni supplies all accessories for access control application including maglock, electric bolt lock, electric strike ,exit button, power supply, prox cards or fobs.

The products are manufactured under an ISO 9 0 0 1 & Q C 0 8 0 0 0 0 C e r t i f i e d Q u a l i t y Management Program environment back its product quality, performance and commitment to customer satisfaction.

Copyright 2008 Gianni industries, inc. All rights reserved. DM-CA-Keyprox Plus Ver. B Published on 2008.05.21

Image 2
Contents Features StatementTwo Door System ApplicationSingle Door System Warranty Multi-Controller System