Gianni Industries DG-15 Series specifications

Page 3

Note:

‹The suggested wire gauge is #22~26 AWG.

‹The varistor or diode must be connected across the lock terminal (electromagnet...) operated by the device. The vartistor controls the overload produced by the strike coil (EMP).

‹Egresses switch should be N.O. type.

‹REED contact input for anti-trailingRelay 1. Contact door reed switch, this reed

switch is used to reset the re-locking time to 0 second when the door is moved. Using N.O. contact in case of door closed changeover to N.C. When door is moved.

Copyright Gianni Industries, Inc. All Rights Reserved.

 

P-MU-DG15 Ver. C Publish:2008.11.12

Page: 3/ 3