LG Electronics A2UH243FA0(LMU240HE), AMNH123APM0(LMAN120HNS) Function of Outdoor Unit

Page 47

Operation

FunctionofOutdoor Unit

Outdoor Unit

Two Comp algorithm

Inverter Comp is first priority and then Constant Comp is turning on responding to load condtion.

Operating Step

Compressor step varies considering condition such as room temp,outdoor temp, operating room number,Temp gap between room temp and set temp and so on.

LEV Control

LEV pulse is modulated to keep constant superheat or subcooling.

Out door Fan Control

Outdoor fan operates at High or Off to respond to the load condition.

R/Valve Control(Heating Model Only)

Convert R/Valve to change cooling to heating, heating to cooling.

Defrost Function

After 45 min heating operation, check the defrost condition and if outdoor pipe temp is below -

5°C(23°F) and released from deice operation in case outdoor pipe temp is over 12°C(53.6°F) or 9 min cooing mode.

To deice outdoor heat exchanger in low temp condtion, convert operating mode from heating to

Oil Return System

In single(one) comp operation duration, another comp will operate for 30 seconds every 1 hours.

Comp Overload Protection

To protect comp from being overload, protector will turn off the comp.

High Pressure Protction

If cycle pressure is too high(around 36.7 kgf/cm2), it will turn off comp A

Service Manual 47

Image 47
Contents Indoor Unit Room Type Art Cool Type Multi Type Air ConditionerTable of Contents Outdoor Unit Model Number NomenclatureIndoor Unit Combination table Symbols Used in this ManualControl box securely Cuit and breaker Safety PrecautionsInstallation Be sure not to do Be sure to follow the instructionOperation Do not place anything on the power cableBe cautious when unpacking Be sure the installation area does not deteriorate with ageHurricane arrives Nect the power supply cableDo not allow water to run into electric parts Smoke comes from productNot enter the product When the product is soakedInstall the drain hose to ensure that Keep level even when Installing the productNot use harsh detergents, sol OperationalAir flow Vents, etcDo not drink the water drained from the product Ly. Clean the filter every twoWhen cleaning or maintaining Do not step on or put anyting on the product. outdoor unitsSplit Type Indoor DimensionsIndoor Unit Outdoor Unit Indoor Unit Product SpecificationsModel A2UC243FA0LMU240CE A2UH243FA0LMU240HE Outdoor Unit Multiple piping modelsInstallation Tools InstallationInstallation Parts Outdoor unit Rooftop InstallationsSelect the best location 24k Piping length and elevationMulti Piping Type Fixing Installation PlateStandard Type Drain hose junction Preparing work for Installation Artcool Type OnlyOpen panel front Remove cover pipe and cover sideDrive the fore plastic anchors into drilled points Sticking the installation guide map and fixing Indoor unitPut an Installation Guide Map on the desired surface Drill a hole in the wallFlaring work Flaring Work and Connection of PipingIndoor Connecting the PipingCheck Wrap the insulation material around the connecting por- tion For left rear piping Connection Indoor Drive two screws Panel AssemblyArt Cool Type onlyBad case Good caseRemote Control Preparationoptional Outdoor unit OutdoorConnect the cable to the Indoor unit Connecting the Cable between Indoor Unit and Outdoor UnitOutdoor unit Connect the cable to the Outdoor unitHow to connect wiring to the terminals Connection method of the connecting cableExampleAttach the Grille onto the cabinet Drain piping Checking the drainageTo check the drainage Forming the piping Leakage test Air Purging and EvacuationChecking method PreparationFinishing the job Repeat evacuation procedure for each indoor unitEvacuation Additional ChargingSplit, Art Cool Type Test RunningOperation Cooling Mode OperationSoft Dry Operation Mode Heating Mode OperationFuzzy Operation for Cooling Defrost ControlHeatingFuzzy Operation Fuzzy Operation for Dehumidification On-Timer OperationOff-Timer Operation Airflow Speed SelectionChaos Natural Wind Mode Off-Timer = On-Timer OperationSleep Timer Operation Chaos Swing ModeBuzzer Sounding Operation Forced OperationSplit Type Indoor Unit Function of Indoor UnitDefrostDeice control Heating IndicatorArt Cool Type Indoor Unit OperationFunction of Outdoor Unit 15 2nd F Button Remote Control OperationCooling Model , Heat Pump Model To remove the Grille from the Chassis DisassemblyTo remove the Control Box To remove the Motor Cover To remove the Control Box To remove the Motor To remove the EvaporatorBefore removing the Turbo Fan Split Type Schematic DiagramElectronic Control Device Outdoor TMP87CM41F RY-4WAY RY-LIQ RY-GAS RY-FANL RY-FANH Art Cool Type Indoor Unit Wiring DiagramBottom View Components LocationsArt Cool Type Schematic Diagram Component side Solder side A2UC243FA0 LMU240CE Troubleshooting GuideRefrigeration Cycle Diagram A2UH243FA0LMU240HESelf-diagnosis Function Indoor ErrorOutdoor Error Error IndicatorTrouble analysis Cycle Troubleshooting GuideProcedure Specification Remedy Electronic Parts Troubleshooting GuideProduct doesnt operate with the remote controller Check Point Comp. on Comp. OFF Compressor/Outdoor Fan are dont operateNector Trouble 4 When indoor Fan does not operateTroubleshooting Guide Indoor inlet pipe sensor Error CodeCheck Point Indoor air sensorCommunication line is shorted at GND Power input AC 230V.Outdoor, IndoorError Title Cause of error Check point & Normal condition Pipe sensor Title Cause of error Check point & Normal conditionOutdoor air sensor Condensor pipe sensorWay Valve Liguid Side Way, 3-way ValveSet the liquid side valve to the closed position ProcedurePumping down Air purging of the charge hoseAll amount of refrigerant leaked Mount the valve caps and the service port capsEvacuation Connect the gauge to the charging cylinder Mount the valve stem nuts and the service port nutGas Charging After EvacuationS4, SE chassis Exploded View & Replacement Parts ListLMN090HE Parts List S4, SE chassisS4 chassis SE chassis SP3 Chassis Art Cool Type Filter ASSEMBLY,AIR Cleaner Parts List SP3 chassisA2UC243FA0 LMU240CE Description Parts List A2UH243FA0LMU240HE, A2UC243FA0 LMU240CELocation April No A20462Z

AMNC093APM0(LMAN090CNS), AMNH123DEA0 (LMN120HE), A2UC243FA0 (LMU240CE), AMNH123APM0(LMAN120HNS), A2UH243FA0(LMU240HE) specifications

LG Electronics has established a prominent position in the HVAC (heating, ventilation, and air conditioning) market with its diverse range of air conditioning units, including models AMNH123APM0 (LMAN120HNS), AMNH123DEA0 (LMN120HE), AMNC123DEA0 (LMN120CE), A2UH243FA0 (LMU240HE), and A2UC243FA0 (LMU240CE). Each of these models is designed to provide efficient cooling and heating solutions, boasting advanced technologies and user-friendly features.

The AMNH123APM0 (LMAN120HNS) model stands out for its energy efficiency, thanks to its inverter technology that adjusts power consumption according to the cooling or heating demand. This feature not only reduces energy costs but also enhances the lifespan of the unit. Additionally, its compact design allows for easy installation in various residential or commercial settings.

Similarly, the AMNH123DEA0 (LMN120HE) offers robust performance with its variable-speed compressor technology. This model ensures precise temperature control and minimal fluctuations, promoting comfort throughout the space. The unit also incorporates a quiet operation mode, making it ideal for bedrooms or offices where noise levels need to be minimized.

The AMNC123DEA0 (LMN120CE) is another compelling choice, featuring a sleek design that fits seamlessly into any décor. It operates efficiently in various weather conditions, maintaining a consistent indoor climate year-round. Its smart diagnostic system simplifies maintenance, allowing for timely troubleshooting and ensuring long-term reliability.

For larger spaces, the A2UH243FA0 (LMU240HE) and A2UC243FA0 (LMU240CE) models provide effective solutions with their powerful cooling and heating capacities. These units are equipped with multi-zone capabilities, allowing users to customize temperatures for different areas of a building. The advanced filtration system in these models captures dust and allergens, improving indoor air quality.

Another noteworthy feature across these models is their SmartThinQ technology, which enables users to control their systems remotely via a smartphone app. This feature not only adds convenience but also facilitates energy management by allowing users to monitor and adjust settings on the go.

In conclusion, LG Electronics offers a range of HVAC solutions with its AMNH123APM0, AMNH123DEA0, AMNC123DEA0, A2UH243FA0, and A2UC243FA0 models. With energy-efficient technology, user-friendly features, and advanced performance capabilities, these air conditioning units are designed to meet the diverse cooling and heating needs of modern consumers while ensuring environmental sustainability.