OPERATING AND SAFETY PRECAUTIONS
READ, UNDERSTAND, AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE.
|
|
|
|
|
| supplier for proper handling instructions. | |||
EXCESSIVE AIR PRESSURE | HAZARDOUS MATERIALS |
|
| ||||||
|
|
| WARNING | EXPLOSION HAZARD. Models containing alumi- | |||||
STATIC SPARK | HAZARDOUS PRESSURE |
|
|
| |||||
|
|
| num wetted parts cannot be used with | ||||||
|
|
|
|
|
| ||||
|
|
|
|
|
| thylene Chloride or other Halogenated Hydrocarbon solvents | |||
|
|
|
|
| |||||
| EXCESSIVE AIR PRESSURE. Can cause person- |
| which may react and explode. | ||||||
WARNING | |||||||||
|
|
| S Check pump motor section, fluid caps, manifolds and all | ||||||
al injury, pump damage or property damage. | |||||||||
S Do not exceed the maximum inlet air pressure as stated on the |
| wetted parts to assure compatibility before using with solvents | |||||||
pump model plate. |
|
|
|
| of this type. |
|
| ||
S Be sure material hoses and other components are able to with- |
| WARNING | MISAPPLICATION HAZARD. Do not use models | ||||||
stand fluid pressures developed by this pump. Check all hoses |
| containing | aluminum wetted parts with food products for hu- | ||||||
for damage or wear. Be certain dispensing device is clean and |
| man consumption. Plated parts can contain trace amounts of | |||||||
in proper working condition. |
|
|
|
| lead. |
|
| ||
WARNING | STATIC SPARK. Can cause explosion resulting in |
| CAUTION |
| Verify the chemical compatibility of the pump | ||||
severe injury | or death. Ground pump and pumping system. |
| wetted parts | and the substance being pumped, flushed or re- | |||||
S Use the pump grounding screw terminal provided. Use ARO |
| circulated. Chemical compatibility may change with tempera- | |||||||
part no. |
| ture and concentration of the chemical(s) within the | |||||||
(12 ga. min.) to a good earth ground source. |
| substances being pumped, flushed or circulated. For specific | |||||||
S Secure pump, connections and all contact points to avoid |
| fluid compatibility, consult the chemical manufacturer. | |||||||
vibration and generation of contact or static spark. |
|
|
| Maximum temperatures are based on mechani- | |||||
| CAUTION | ||||||||
S Consult local building codes and electrical codes for specific |
|
|
|
|
| ||||
| cal stress only. Certain chemicals will significantly reduce | ||||||||
grounding requirements. |
|
|
|
| maximum safe operating temperature. Consult the chemical | ||||
S After grounding, periodically verify continuity of electrical path |
| ||||||||
| manufacturer for chemical compatibility and temperature lim- | ||||||||
to ground. Test with an ohmmeter from each component (e.g., |
| its. Refer to PUMP DATA on page 1 of this manual. | |||||||
hoses, pump, clamps, container, spray gun, etc.) to ground to |
| ||||||||
| CAUTION |
| Be certain all operators of this equipment have | ||||||
insure continuity. Ohmmeter should show 0.1 ohms or less. |
|
| |||||||
| been trained for safe working practices, understand it’s limita- | ||||||||
S Submerse the outlet hose end, dispensing valve or device in |
| ||||||||
| tions, and wear safety goggles / equipment when required. | ||||||||
the material being dispensed if possible. (Avoid free streaming |
| ||||||||
| CAUTION | Do not use the pump for the structural support of | |||||||
of material being dispensed.) |
|
|
|
| |||||
S Use hoses incorporating a static wire. |
|
|
|
| the piping system. Be certain the system components are | ||||
S Use proper ventilation. |
|
|
|
| properly supported to prevent stress on the pump parts. | ||||
S Keep inflammables away from heat, open flames and sparks. | S Suction and discharge connections should be flexible connec- | ||||||||
S Keep containers closed when not in use. |
| tions (such as hose), not rigid piped, and should be compatible | |||||||
|
|
|
|
|
| with the substance being pumped. | |||
WARNING | Pump exhaust may contain contaminants. Can | ||||||||
| injury. Pipe exhaust away from work area and per- |
| CAUTION |
| Prevent unnecessary damage to the pump. Do | ||||
cause severe | |||||||||
sonnel. |
|
|
|
| not allow pump to operate when out of material for long periods | ||||
S In the event of a diaphragm rupture, material can be forced out |
| of time. |
|
| |||||
of the air exhaust muffler. |
|
|
| S Disconnect air line from pump when system sits idle for long | |||||
S Pipe the exhaust to a safe remote location when pumping haz- |
| periods of time. | |||||||
ardous or inflammable materials. |
|
|
|
| CAUTION | Use only genuine ARO replacement parts to as- | |||
S Use a grounded 1” minimum i.d. hose between the pump and |
| sure compatible pressure rating and longest service life. | |||||||
the muffler. |
|
|
|
|
|
|
|
|
|
|
|
|
| NOTICE |
| Replacement warning labels are available upon | |||
WARNING | HAZARDOUS PRESSURE. Can result in serious |
| request: “Static Spark & Diaphragm Rupture” pn \ 94080. | ||||||
injury or property damage. Do not service or clean pump, |
|
|
|
|
| ||||
hoses or dispensing valve while the system is pressurized. |
|
|
|
|
|
| |||
|
|
|
| = Hazards or unsafe practices which could | |||||
S Disconnect air supply line and relieve pressure from the sys- |
|
| |||||||
| WARNING | ||||||||
tem by opening dispensing valve or device and / or carefully |
|
|
| result in severe personal injury, death or | |||||
and slowly loosening and removing outlet hose or piping from |
|
|
| substantial property damage. | |||||
pump. |
|
|
|
|
| = Hazards or unsafe practices which could | |||
|
|
|
| CAUTION | |||||
WARNING | HAZARDOUS MATERIALS. Can cause serious in- |
|
|
| result in minor personal injury, product or | ||||
|
|
| |||||||
jury or property damage. Do not attempt to return a pump to the |
|
|
| property damage. | |||||
factory or service center that contains hazardous material. |
|
| = Important installation, operation or main- | ||||||
| NOTICE | ||||||||
Safe handling practices must comply with local and national |
|
|
| tenance information. | |||||
|
|
| |||||||
laws and safety code requirements. |
|
|
|
|
|
|
|
|
SObtain Material Safety Data Sheets on all materials from the
Page 2 of 8 |