Multiquip SS-233 manual Power Cord Wet Hands, Pump Shut-Down/Clean-up

Page 12

STOW SS-233 SUBMERSIBLE PUMP OPERATION

4.NEVER! grab or touch a live power cord (Figure 4) with wet hands, the possibility exists of electricalshock, electrocu- tion and even death.

WET

HANDS

POWER

CORD

(POWER ON)

Figure 4. Power Cord (Wet Hands

DANGER:

NEVER! grab or touch a live power cord. DO NOT stand in water when connecting the pump's power cord into a voltage source.The possibility exist of electrical shock, electrocution and possibly death!

3.If all of the pump's electrical requirements have been met, insert the power plug (Figure 5) on the pump into the power source receptace. Make sure the extension cord is of proper size,seeTable3. It is recommended thatthepump'spower cord be plugged into a GFCI receptacle to prevent the possibility of electrical shock.

Figure 5. Conneting the Power

4.Wait a few seconds and water should begin to flow from the discharge hose.

5.If water is not flowing from the discharge hose or not flowing freely after a few minutes, remove the power from the pump and check the system for leaks.

Pump Shut-Down/Clean-up

1.Remove the power from the pump by turning off the circuit breaker or switch that provides power to the pump. Remem- bertomakesurethathandsaredry(notwet),andfeetarenot standing in water when removing or disconnecting power from the pump.

2.Usingtheliftingrope,liftthepumpupfromitscurrentposition. Remove the discharge hose from the discharge port on the pump.

3.Ifthepumpwasusedtopumpmud,gritorsilt,flush vigorously with clean water.

4.Removethepumpfromthewater.Wipeoffanymudordebris that might have attached itself to the pump.

5.Store pump in a clean dry place away from dirt and debris.

WARNING:

NEVER! cut or remove the ground prong from the pump's AC power cord.

WARNING:

This pump is supplied with a grounding conductor and a grounding-type attachement plug. To reduce the possibility of electric shock, make certain that pump is connected only to a properly grounded receptacle.

PAGE 12 — STOW SS-233 SUBMERSIBLE PUMP — OPERATION MANUAL — REV. #2 (05/03/04)

Image 12
Contents Model Heres HOW to GET Help Stow SS-233 Submersible Pump -TABLE of Contents Service Department Warranty DepartmentParts Department Technical AssistanceStowyellow SUB. Pump Safety Message Alert Symbols Understands all Instructions in this manualGeneral Safety Stow SS-233 Submersible Pump Rules for Safe OperationMaintenance Safety EmergenciesDimensions Dia x Height Dry Net Weight ShippingSuction & Discharge Size Stow SS-233 Submersible Pump General Information IntroductionStow SS-233 Submersible Pump Components Operation Submersible Pump Upright Position IncorrectPower Cord Wet Hands Pump Shut-Down/Clean-upStow SS-233 Submersible Pump -TROUBLESHOOTING/CABLE Pump TroubleshootingStow SS-233 Submersible Pump Pump Assy Stow SS-233 Submersible Pump Pump Assy Terms and Conditions of Sale Stow Construction Equipment Page Service DEPARTMENT/TECHNICAL Assistance

SS-233 specifications

The Multiquip SS-233 is a powerful and versatile light tower designed for construction sites, events, and emergency situations that require reliable illumination. Known for its robust construction and advanced technology, the SS-233 provides a reliable lighting solution to enhance safety and productivity in low-light environments.

One of the standout features of the SS-233 is its high-performance lighting capabilities. Equipped with four 1000-watt metal halide lamps, the light tower generates a brilliant illumination covering a large area effectively. The high-intensity lights ensure that even the darkest sites are brightly lit, improving visibility for workers and minimizing accidents.

The SS-233 incorporates a heavy-duty telescoping mast that extends up to 30 feet, allowing for optimal light distribution at various heights. This adjustability is particularly beneficial on uneven terrain, making it incredibly flexible for different project needs. The mast is easily deployable and retractable, which simplifies setup and takedown processes.

In terms of power, the Multiquip SS-233 runs on a robust diesel engine known for its efficiency and longevity. Its fuel capacity allows for extended operation, ensuring that the lights remain on throughout the night or during prolonged projects without frequent refueling interruptions. The engine is compliant with emission regulations, contributing to a lower environmental impact.

Another remarkable characteristic of the SS-233 is its durability. Constructed with a weather-resistant frame and components, the light tower can withstand various environmental conditions, from rain to harsh sun, making it suitable for both indoor and outdoor applications.

Portability is also a key aspect of the SS-233. It features durable, all-terrain tires for easy mobility across job sites. Additionally, the unit is designed for quick and easy transport, fitting onto standard trailers for enhanced mobility.

Lastly, the Multiquip SS-233 is user-friendly, designed with intuitive controls that allow operators to easily adjust lighting configurations. This convenience ensures that even personnel with minimal training can efficiently operate the unit, enhancing overall productivity on the site.

In summary, the Multiquip SS-233 light tower combines powerful lighting, robust construction, portability, and user-friendly operation, making it an excellent choice for various applications where reliable illumination is crucial.