Specifications

Model LP700

High-Pressure Plunger Pump

Volume

7.9 GPM

Maximum Discharge Pressure

7250 PSI

Maximum Inlet Pressure

Up to 90 PSIG1

RPM

1000

Plunger Diameter

18mm

Stroke

42mm

Crankcase Oil Capacity

102 fl. oz.

Temperature of Pumped Fluids

Up to 104 oF

Inlet Port

2 x 3/4" NPT

Discharge Ports

2 x 1/2" NPT

Shaft Rotation

Either Direction2

Weight

173 lbs.

Width

20.9"

Height

7.9"

 

LP700 HORSEPOWER CHART

 

RPM

GPM

3000 PSI

5000 PSI

6000 PSI

7250 PSI

500

3.9

8.1

13.5

16.3

 

19.6

600

4.7

9.8

16.3

19.6

 

23.7

700

5.3

11.0

18.4

22.1

 

26.7

800

6.3

13.1

21.9

26.3

 

31.7

900

7.1

14.8

24.7

29.6

 

35.7

1000

7.9

16.5

27.4

32.9

 

39.8

HORSEPOWER RATINGS: The rating shown are the power

requirements for the pump. Gas engine power outputs must be approximately twice the pump power requirements shown above.

We recommend a 1.15 service factor be specified when selecting an electric motor as the power source. To compute specific pump horse- power requirements, use the Follow- ing formula:

HP = (GPM X PSI) / 1440

3

Image 3
Contents Model LP700 Important Operating Conditions Installation InstructionsHorsepower Ratings The rating shown are the power LP700 Horsepower ChartLP700 Exploded View Position Description Model LP700 Parts ListLP700 Kits Torque Specifications Packing Kit Valve AssemblyRepair Instructions Model LP700 Valve ReplacementModel LP700 Dimensions inches Giant Industries Limited Warranty