ITT BPHV manual Applications

Page 8

Goulds Pumps

PHV - Packaged Hydrovar Series

MARKETS AND APPLICATIONS

(continued)

MUNICIPAL, AGRICULTURAL, LIGHT INDUSTRY,

WATER TREATMENT, HEATING AND AIR CONDITIONING

APPLICATIONS

Handling of water, free of suspended solids, in the municipal, industrial and agricultural markets

Pressure boosting and water supply systems

Fire fighting jockey pumps

Irrigation systems

Wash systems

Water treatment plants: reverse osmosis

Handling of moderately aggressive liquids, demineralized water, water and glycol, etc.

Circulation of hot and cold water for heating, cooling and conditioning systems

Boiler feed

SPECIFICATIONS

PUMP

The SSV pump is a non-self priming vertical multistage pump coupled to a standard motor.

The liquid end, located between the upper cover and the pump casing, is held in place by tie rods. The pump casing is available with different configurations and connection types.

Delivery: up to 600 GPM

Head: up to 1200 feet

Temperature of pumped liquid: -20ºF to 250ºF (-30ºC to 120ºC) standard version

• Maximum operating pressure – with oval flanges: 230 PSI (15 bar)

with round flanges or Victaulic: 360 PSI (25 bar)

SV33, 46: 230, 360 or 575 PSI (16, 25 or 40 bar)*

SV 66, 92: 230 or 360 PSI (16 or 25 bar)*

Direction of rotation: clockwise looking at the pump from the top down (marked with an arrow on the adapter and on the coupling).

MOTOR

Standard NEMA TC Frame motors totally enclosed fan cooled.

Efficiency is 75.5% or higher, Class “F” insulation

3500 RPM nominal

Standard voltage:

Single phase version: 115-208/230 V, 60 Hz up to 3 HP or 208-230 V for 5 HP

Three phase version, 2 pole: 208-230/460 V, 60 Hz up to 75 HP

* Based on pump staging

8

Image 8
Contents Goulds Pumps Contents Goulds PumpsSSV Flow Main Components PHV Series constant pressure variable speed system Part Numbering / Identification Codes PHV Series HV M 3 4Specifications Markets and ApplicationsMarkets Served MUNICIPAL, COMMERCIAL, IndustrialIrrigation and Agriculture Applications Further information is available in the Hydrovar manual ANSI/NSF 61 certified by CSA for potable drinking water SV33 and 46 MULTI-STAGE PumpsReference Standards Introduction Standard Optional Features VersionsHydrovar Versions Application Example MULTI-PUMP Cascade Operating Characteristics and Limits Operation DescriptionNoise Emission Levels 60 Hz 3500 RPM LpA dB ±4Selecting a SET Calculating the Flow RateFused Disconnect BOX Customer SuppliedInstall Power Supply Hydrovar VFD MotorMotor Data 3500 RPM, 60 HzMake the following calculation Performance with Varying Speed for Centrifugal PumpsSizing the Diaphragm Tank in Systems with Speed Variation Variable Speed Performance Curves 1SV Variable Speed Curve Ssvb 304SSModel 1SVB 6 Stage Hydraulic DataModel 1SVB 9 Stage Npsh RModel 1SVB 15 Stage 2SV Variable Speed Curve Ssvb 304SS Model 2SVB 5 StageModel 2SVB 8 Stage Model 2SVB 13 Stage 3SV Variable Speed Curve Ssvb 304SS Model 3SVB 7 StageModel 3SVB 9 Stage Model 3SVB 13 Stage Model 4SVB 2 Stage US GPM Feet4SV Variable Speed Curve Ssvb 304SS Model 4SVB 4 StageModel 4SVB 7 Stage 33SV Variable Speed Curve SVB CI/316SS Model 33SVB 1/1 StageModel 33SVB 1 Stage Model 33SVB 2/1 Stage Model 33SVB 3/1 Stage 46SV Variable Speed Curve SVB CI/316SS Model 46SVB 1/1 StageModel 46SVB 1 Stage Technical Data Pump Hydraulics / Motor Sizing 1SV 3500 RPM2SV 3500 RPM 3SV 3500 RPM4SV 3500 RPM 33SV 3500 RPM46SV 3500 RPM 66SV 3500 RPMTechnical Data Maximum Inlet PressurePHV Packaged Hydrovar Series 1SVB TefcPHV Packaged Hydrovar Series 2SVB PHV Packaged Hydrovar Series 3SVB PHV Packaged Hydrovar Series 4SVB PHV Packaged Hydrovar Series 33SVB PHV Packaged Hydrovar Series 46SVB Npsh Technical Data Water Property Chart Cubic ft/lb @ 39.2ºF @ 60ºF @ 68ºF Lb/cubic ft Psi AbsVolumetric Capacity VolumePressure and Head LengthGoulds Pumps Page Engineered for life