Enviro 50-765 Installation of firebox backing, Post Season CLEAN-UP, Cleaning Plated Surfaces

Page 12

Routine Cleaning and Maintenance

EXHAUST PASSAGES (season)

Removal of the firebox backing for bi- annual cleaning (refer to Figure 10):

• Open the door by lifting the handle, remove the burn pot and burn pot liner.

• Lubricate all screws with penetrating oil.

• Remove the four (4) screws that hold the brick liner retainers in place. Remove side brick liners by sliding them forward then out.

• Pull the center panel out.

• Vacuum and clean thoroughly.

Installation of firebox backing:

• Insert center panel with backing.

• Place the two (2) side panels back into the firebox and reinstall the two (2) retainers using two (2) screws on each side.

• Replace the burn pot and burn pot liner

• Close the glass door and secure.

Figure 11: Firebox Components Removal.

POST SEASON CLEAN-UP

Once you are finished using the pellet appliance for the season, unplug the stove for added electrical protection. It is very important that the stove be cleaned and serviced as stated above.

CLEANING PLATED SURFACES

Painted surfaces should be wiped with a damp cloth periodically.

It is important to note that fingerprints and other marks can leave a permanent stain on plated finishes. To avoid this, give the surface a quick wipe with denatured alcohol on a soft cloth BEFORE lighting the fireplace. Never clean surfaces when they are hot. Do not use other cleaners or abrasives as they may leave a residue or scratches, which can become permanently etched into the surface.

FIREBOX PANEL

The paint on the steel firebox panels may peel. This is due to extreme conditions applied to the paint and is in no way covered by warranty.

REPLACING DOOR GLASS

It is recommended that your ENVIRO dealer replace the glass if broken.

The door glass is made of high temperature PYRO CERAMIC 5 mm thick. The center panel is 15.4” x 9.0” (39.0 cm x 22.9 cm) and side panels are 2.6 x 9.0 inches (6.7 cm x 22.9 cm). They must be replaced with (Part # EF-062). Substitute materials will not be permitted.

12

Image 12
Contents Meridian Table of Contents Introduction I. Pellet StandardsStore pellets at least 36 1 m away from the pellet stove USE of Cordwood is Prohibited by LAW Keep ASH PAN Free of RAW Fuel Specifications Meridian Freestanding DimensionsReasons WHY the Unit Overheated Operating InstructionsOperation When the thermostat contacts close, the unit will Special Notes Slider / Damper KnobRoutine Cleaning and Maintenance Tools Required to Clean UnitDoor Glass Cleaning 2-3 days Burn POT and Liner 2-3 daysDo not Place Unburned or RAW Pellet Fuel in ASH PAN Installation of firebox backing Post Season CLEAN-UPCleaning Plated Surfaces Firebox PanelWarranty To the DealerWarranty Installation Data Sheet Name of Owner Address