Avalon Stoves 99200149, ZC Kit dimensions Compatibility Packing List, Installation Overview

Page 1

 

ZC Kit – Large Pellet Insert

 

(99200149)

Compatibility

Packing List

Astoria Bay Pellet Insert

ZC Can Rear Panel

ZC Can Top/Side Panel

Yankee Bay Pellet Insert

ZC Can Rear Vent Shield

 

(26) # 8 x 3/8” Type A Screws

Overview

This kit allows an installer to build the above pellet heaters into the framing of a home.

Installation Overview

The minimum framing dimensions and clearances listed in this instruction sheet must be maintained. Failure to follow all of the instructions in this instruction sheet, and in the manual, will void the listing and warranty of the pellet heater, and may create a serious fire hazard.

This kit is approved for use in a mobile home.

1Determine the vent configuration (see “Vent Requirements” and “Vent Termination Requirements”)

2Prepare the enclosure (see “Minimum Enclosure Dimensions”).

3Install the floor protection and hearth (see “Minimum Floor Protection”).

If venting to the rear (most common)

Place the 90° onto the insert starter collar and measure the height of the center of the vent. This will determine the center height of the wall thimble installed behind the insert in the wall. NOTE: The vent is located 7.5” left of center of the appliance. Install the thimble into the wall, making sure the 3” clearance to combustibles is met (refer the directions included with the thimble for additional details). Remove the starter collar from the pellet heater and install it onto the elbow (seal with silicone). Determine the correct length for the horizontal section of vent (the center of the starter collar is 11.25” behind the enclosure opening) and attach it to the elbow (seal with silicone). Place this flue section aside until after the zc can is installed. Then insert the flue section through the can and thimble. Once the insert is in place, attach the starter section to the insert (it is attached with a latch – make sure the gasket is correctly positioned). Attach the additional vent components to finalize the vent installation (termination, elbow, etc.).

If venting upwards

When installing with vertical vent, the area above the insert must be accessible after the zc can and insert have been installed (note: the vent is located 11.25” behind the enclosure opening, 7.5” left of center). Remove the starter collar from the pellet heater and install it onto the vent (seal with silicone). Insert this vent through the zc can and attach the starter section to the insert (it is attached with a latch – make sure the gasket is correctly positioned). Attach the additional vent components to finalize the vent installation (additional vent lengths, elbows, terminations, etc.).

3Construct and Install the ZC Can (see “ZC Can Construction and Placement”)

4Prepare the insert in place it into the ZC Can (see “Insert Preparation and Placement”)

Page 1 of 8

10/9/06

© Travis Industries, Inc.

Image 1
Contents Compatibility Packing List Installation OverviewOverview Vent Requirements Vent Termination Requirements See the illustration below Minimum Enclosure Dimensions Floor 45 Min Width of surround panels 18 Min Minimum Floor ProtectionConstruct the zc can as shown below ZC Can ConstructionZC Can Placement Connection Insert Preparation and Placement

99200149, ZC Kit specifications

Avalon Stoves ZC Kit, model number 99200149, is an exceptional zero clearance kit designed specifically for use with Avalon’s extensive range of wood and gas stoves. This innovative kit allows for a seamless integration of Avalon stoves into various installation environments, such as custom-built fireplaces or framed enclosures.

One of the main features of the ZC Kit is its zero clearance capability. This means that the unit can be installed directly against combustible materials, a significant advantage for homeowners looking to retrofit existing spaces without extensive renovations. This feature not only simplifies installation but also enhances the versatility of the product, as it can fit into tight spaces where traditional stoves cannot.

The design of the Avalon Stoves ZC Kit prioritizes safety and efficiency. It is equipped with insulated panels that help maintain optimal temperatures, preventing excessive heat from escaping into surrounding structures. This thermal efficiency translates to increased heat output, making the ZC Kit ideal for heating larger areas.

Furthermore, the Avalon Stoves ZC Kit incorporates cutting-edge technologies that improve both functionality and user experience. The kit features adjustable vents that allow for better airflow management, ensuring that heat is distributed evenly throughout the space. This ensures that a comfortable living environment is maintained even during the coldest months of the year.

Another characteristic of the ZC Kit is its compatibility with various Avalon stove models. This ensures that customers can choose a stove that fits their aesthetic desires without sacrificing performance or safety. The unit is also designed for easy maintenance, with access points that allow for straightforward cleaning and servicing.

Overall, the Avalon Stoves ZC Kit, 99200149, stands out in the market for its combination of safety, efficiency, and convenience. Its zero-clearance design, advanced airflow management, and compatibility with multiple stove models make it an excellent choice for any homeowner seeking to enhance their heating capabilities. Whether for new constructions or retrofitting existing spaces, the ZC Kit not only meets but exceeds expectations, delivering both warmth and style.