Avalon Stoves Freestanding Stove owner manual Safety Precautions, If YOU Smell GAS

Page 4

4

Ok

Safety Precautions

• IF YOU SMELL GAS:

*Do not light any appliance

*Extinguish any open flame

*Do not touch any electrical switch or plug or unplug anything

*Open windows and vacate building

*Call gas supplier from neighbor's house, if not reached, call fire department

This unit must be installed by a qualified installer to prevent the possibility of an explosion. Your dealer will know the requirements in your area and can inform you of those people considered qualified. The room heater should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be

required due to excessive lint from carpeting, bedding material, etc.

The instructions in this manual must be strictly adhered to. Do not use makeshift methods or compromise in the installation. Improper installation will void the warranty and safety listing.

Look for this label:

 

 

 

• This heater is either approved for natural

 

 

 

 

 

 

 

For LPG only Pout 11” W.C.

 

 

 

 

 

gas (NG) or for propane (LP or LPG).

 

 

 

 

 

 

 

 

Burning the incorrect fuel will void the

 

 

 

 

 

 

If the label is present, the

 

 

 

 

 

warranty and safety listing and may cause

 

 

 

 

 

 

an extreme safety hazard. Direct

 

heater is equipped for LP

 

 

 

 

 

 

 

 

 

 

 

questions about the type of fuel used to

 

(propane). If the label is

 

 

 

 

 

 

absent, the heater is equipped

 

 

 

your dealer. Check for the label shown to

 

for NG (natural gas).

 

 

 

 

 

the right.

 

• Contact your local building

 

 

 

 

 

 

 

• If the flame becomes sooty,

officials to obtain a permit

 

 

 

 

 

 

 

dark orange in color, or

and information on any

 

 

 

 

 

 

 

 

extremely tall, do not

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

installation restrictions or

 

 

 

 

 

 

 

 

operate the heater. Call

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

inspection requirements in

 

 

 

 

 

 

 

 

your dealer and arrange for

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

your area. Notify your

 

 

 

 

 

 

 

 

proper servicing.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

insurance company of this

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

heater as well.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• It is imperative that control

?

 

• Do not operate the heater if

compartments, screens, or

 

it is not operating properly in

circulating air passageways

 

any fashion or if you are

of the heater be kept clean

 

uncertain. Call your dealer

and free of obstructions.

 

for a full explanation of your

These areas provide the air

 

heater and what to expect.

necessary for safe

 

 

operation.

 

 

 

 

 

 

 

 

 

 

 

 

• Do not use this appliance if

• Do not store or use gasoline

 

 

 

 

 

 

 

any part has been under

 

 

 

 

 

 

 

 

 

 

 

 

 

 

water. Immediately call a

or other flammable liquids in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

qualified service technician

the vicinity of this heater.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to inspect the appliance and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to replace any part of the

 

 

 

 

 

 

 

 

 

 

control system and any gas

 

 

 

 

 

 

 

 

 

 

control which has been

 

 

 

 

 

 

 

 

 

 

under water.

Travis Industries

9 3 5 0 8 1 1 5

4 0 5 0 1 1 3

Image 4
Contents Featuring the Burner Introduction Important Information Introduction and Important InformationTravis Industries 5 0 8 1 1 5 0 1 1 Table of Contents Safety Precautions If YOU Smell GASThis Manual 6Features and Specifications Heating SpecificationsElectrical Specifications for optional blower FuelInstallation Overview Installation WarningsPacking List Additional Items Required Installation Hints Straight InstallationsCorner Installations Stove ClearancesHeater Placement Requirements Floor Protection RequirementsGas Line Installation Gas Inlet PressureVent Requirements ManuafacturerS e r i e sRestrictor Position Approved Vent ConfigurationsMeasuring Vent Lengths Restrictor Position # Restrictor Restrictor Restrictor Position Restrictor Position # Vent Termination Requirements see illustration below Finalizing the Installation Adjusting the AIR ShutterFinalizing the Installation for qualified installers only 2 Face and Glass Removal Re-Attaching the Glass FrameGlass Frame Removal and Installation Log Installation Operation2 Before You Begin Location of Controls See explanation below6Operation Starting The Pilot FlameStarting the Stove for the First Time Adjusting the Flame HeightTurning the Stove On and Off Adjusting the Blower Speed optional 8OperationNormal Operating Sounds Normal Operating OdorsYearly Service Procedure Maintaining Your Stoves AppearancePainted Surfaces GlassMaintenance TroubleshootingWhat Turns the Main Burners On and Off How this Stove WorksWhat Prevents Gas Buildup Wiring Diagram Replacement Parts ListSafety Label Prairie4Limited 7 Year Warranty Years 1 & 2 Coverage Parts & LaborYears 3 Through 5 Coverage Parts & Labor Years 6 & 7 Coverage Parts onlyLP Conversion Instructions Optional Equipment for qualified installers only Off the pilot Blower Back StoveBack Stove Fireback Addendum #1 Class a Chimney Conversion Kit Installation AddendaAddendum #2 Interior Masonry Chimney Conversions 2Index

Freestanding Stove specifications

Avalon Stoves has earned a reputation for quality and innovation in the hearth industry, and their Freestanding Stove is a testament to this commitment. Designed to provide both aesthetic appeal and efficient heating, the Avalon Freestanding Stove is an excellent choice for those looking to elevate their home’s ambiance while ensuring warmth during cold months.

One of the main features of the Avalon Freestanding Stove is its powerful heating capacity. With advanced firebox engineering, it can efficiently heat areas ranging from 1,200 to 2,500 square feet, depending on the model and installation. This versatility makes it suitable for a variety of home sizes and layouts, providing an inviting warmth for family gatherings or cozy nights in.

The stove is built with high-quality materials, featuring a heavy-duty cast iron construction that ensures durability and longevity. The high-temperature ceramic glass window offers not only a beautiful view of the fire but also serves a functional purpose by withstanding intense heat. This adds a charming focal point to any room while allowing users to safely enjoy the flicker of flames.

Equipped with advanced technologies, the Avalon Freestanding Stove incorporates a clean-burning system that meets stringent environmental regulations. The primary and secondary air combustion systems work harmoniously to maximize efficiency while minimizing emissions. This ensures that the stove not only heats effectively but also contributes to a cleaner environment, making it an environmentally responsible choice.

Another notable characteristic is its customizable design options. Avalon offers a range of finishes, including traditional cast iron and modern enamel, allowing homeowners to select a style that complements their decor. Additionally, the stove’s compact footprint allows it to fit seamlessly into various spaces, making it a versatile option for homes of different sizes.

User-friendly features are also a hallmark of the Avalon Freestanding Stove. The easy-access lid and large ash pan make maintenance a breeze, ensuring that cleaning is relatively hassle-free. The adjustable air control allows for precise flame regulation, giving users the ability to control the heat output effortlessly.

In summary, the Avalon Freestanding Stove combines powerful heating capabilities with environmentally friendly technologies, timeless design options, and user-friendly features. It stands as an excellent investment for those looking to enhance their living space with both functionality and style. Whether it's for the warmth or the aesthetic, Avalon’s Freestanding Stove is a remarkable addition to any home.