Page 6

FLOOR PROTECTION

It is recommended that this appliance is installed on a solid, level, non combustible hearth conforming to current Building Regulations.

Fig.7

The appliance is suitable for continuous operation on solid mineral fuel and intermittent operation on wood logs. This appliance has been tested using seasoned wood logs and manufactured briquetted smokeless fuel (Ancit) for closed appliances, sized between 20g and 140g. Other fuels are commer- cially available. Wood logs up to 400 mm long are suitable. All fuels should be stored under cover and kept as dry as possible prior to use.

LOCATION

There are several conditions to be considered in selecting a location for your Berrington Stove.

a.Position in the area to be heated- central locations are usually best.

b.Allowances for proper clearances to combustibles.

Note: Sufficient space should be given around the back and sides of the stove to allow access to the air control damper.

INSTALLATION CLEARANCES

Maintain at least the following clearances to all combustible material:

From the front

900 mm

From the Sides

150 mm

From the rear

150 mm

From the flue pipe

600 mm

5

Image 6
Contents Berrington Solid Fuel Boiler Stove Table of Contents PRE Installation Assembly FluesVentilation & Combustion AIR Requirements Flue PipesDown Draughts ChimneyTOP Flue Exit Rear Flue ExitInstallation Clearances Floor ProtectionLocation Specifications Technical DataGravity Circuit Water Circuit TemperaturePlumbing Regulations Operating InstructionsLOW / Slumber Burn Recommended FuelsImportant Notes Fuel Calorific Values Solid FuelsLighting Disposal of Ashes To Clean Chimney OutletDE-ASHING To Replace Damaged Grate or Grate BARGlass Cleaning Fire SafetyVitreous Enamel Cleaning Glass ReplacementBerrington Solid Fuel Boiler Stove Exploded View