Shure KSM137 manual Specifications, Attenuation Switch

Page 7

SPECIFICATIONS

Cartridge Type

Permanently Biased Condenser

 

 

Frequency Response

20–20,000 Hz (see Figure 3)

 

 

Directional Polar Pattern

Cardioid (see Figure 4)

 

 

Output Impedance

150 (actual)

 

 

Attenuation Switch

0 dB,15 dB, or 25 dB attenuation

 

 

Low Frequency Response Switch

Flat; –6 db/octave below 115 Hz;

 

–18 dB/octave below 80 Hz

 

 

Phantom Power

48 Vdc± 4 Vdc (IEC–268–15/DIN 45 596),

 

positive pins 2 and 3

 

 

Current Drain

4.65 mA typical at 48 Vdc

 

 

Common Mode Rejection

50 dB, 20 Hz to 20 kHz

 

 

Polarity

Positive pressure on diaphragm produces positive

 

voltage on output pin 2 relative to pin 3

 

 

Dimensions and Weight

20 mm (0.8 in.) diameter, 122 mm (4.8 in.) long;

 

100 grams (3.5 oz.) (see Figure 5)

 

 

Sensitivity (typical, at 1000 Hz;

–37 dBV/Pa

1 Pa = 94 dB SPL)

 

 

 

Self–noise (typical, equivalent SPL;

14 dB

A-weighted, IEC 651)

 

 

 

Maximum SPL at 1 kHz

145 (160, 170) dB

5000 load (Attenuator on)

2500 load (Attenuator on)

139 (154, 164) dB

1000 load (Attenuator on)

134 (149, 159) dB

 

 

Output Clipping Level*

15 dBV

5000 load

2500 load

9 dBV

1000 load

3 dBV

 

 

Dynamic Range

131 dB

5000 load

2500 load

125 dB

1000 load

120 dB

 

 

Signal to Noise Ratio**

80 dB

 

 

*20 Hz to 20 kHz; THD < 1%. THD of the microphone preamplifier when applied input signal is equivalent to the cartridge output at specified SPL

**S/N ratio is difference between 94 dB SPL and equivalent SPL of self-noise A-weighted.

6

Image 7
Contents KSM137 Thank you for selecting the KSM137 Shure Incorporated KSM137 Cardioid Condenser MicrophoneGeneral Description FeaturesModel Variations Performance CharacteristicsApplications Mounting the Microphone Using the KSM137Setting Attenuation Attenuation Switch SpecificationsTypical Frequency Response Certification Furnished AccessoriesOptional Accessories ServiceE2003, Shure Incorporated 27A3157 CB