Air King 4C630P/9012P specifications Description, Specifications, General Safety Information

Page 1

MODELO 4C630P/9012P y 4C631Q/9016Q

13

 

 

 

 

 

 

21

 

 

 

9

 

 

22

 

 

 

 

 

23

 

 

 

 

 

 

1

2

3

 

 

 

24

 

 

 

 

 

 

 

 

10

 

14

 

 

 

 

5

15

25

 

 

 

 

 

 

 

 

 

 

2

 

8

 

 

18

3

6

7

 

17

 

 

 

 

 

 

 

 

 

 

 

OPERATING INSTRUCTIONS & PARTS MANUAL

WALL MOUNTED

OSCILLATING FANS

12" (30,4 cm) MODEL 4C630P/9012P 16" (40,6 cm) MODEL 4C631Q/9016Q

READ AND SAVE THESE INSTRUCTIONS

READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DE- SCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!

RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

 

 

16

26

 

 

18

 

 

 

4

7

19

24

 

11

 

 

12

20

 

 

 

 

LISTA DE REPUESTOS

Ref.

Parte No. for Modelo

 

 

 

 

No.

4C630P/9012P

4C631Q/9016Q

Descripción

Cant.

1

2060316

2060316

Placa de Montaje

1

 

 

2

2090003

2090003

Tornillo Phillips #8 x 1-1/4"

2

 

 

3

02090045A

02090045A

Tornillo Phillips Tipo 25 #8 x 3/4"6

4

02090272

02090272

Pata de Caucho

2

 

 

5

2060202

2060202

Placa Tracera para Colgar

1

 

 

6

2010554

2010554

Tapa del Interruptor

1

 

 

7

2090008

2090008

Tornillo Phillips #8 x 1/2"

2

 

 

8

02055047

02055047

Interruptor con Cordón

 

 

 

 

 

 

 

 

 

 

 

Accionador

1

 

 

9

7091854

7091854

Plastico Protector

2

 

 

10

2010512P

2010512P

Cuerpo

1

 

 

11

2090539

2090539

Casquillo del Cordón Accionador1

12

02090744

02090744

Tire Cuerda

1

 

 

13

02035035

02035036

Conjunto de Motor

1

 

 

 

 

14

02010162B

02010162B

Placa de Trinquete

1

 

 

15

02090518

02090518

Resorte de Elevación

1

 

 

16

02090521A

02090521A

Eje de Elevación

1

 

 

17

02090033

02090033

Tuerca Hexagonal

1

 

 

18

02010548A

02010548A

Boton Tipo H.C.

2

 

 

 

 

19

2010131

2010131

Botón del Interruptor (Rotatorio) 1

 

20

02050009FPB

02050009FPB

Cordón Eléctrico

1

 

 

21

2011212

2011200M

Rejilla Plástica Trasera

1

 

 

 

22

2010359

2010359

Tuerca de Seguridad

1

 

 

 

23

2010008

2011013

Aspa

1

 

 

 

24

2010058

2010090

Tapa

1

 

 

 

25

02096217

02096214I

Rejilla Frontal

1

 

 

 

 

26

02010381A

02010381A

Ornamento

1

 

 

DESCRIPTION

Air King® 12" (30,4 cm) and 16" (40,6 cm) Wall Mounted Oscillating Fans offer rotary knob/pull cord speed control, variable oscillation, a permanent split capacitor motor and OSHA-complying front steel mesh grill with a 6 ft (1,8m) 18/3 cord set.

SPECIFICATIONS

Motor

 

 

120V, 60 Hz (12" 30,4 cm)

 

 

 

 

 

 

 

120V, 60 Hz (16" 40,6 cm)

 

Blade diameter

12" ( 30,4 cm) Model 4C630P/9012P

 

 

 

 

 

 

16" (40,6 cm) Model 4C631Q/9016Q

Speeds

 

 

3

 

 

 

 

Control

 

 

Rotary Knob/Pull Cord

 

Air flow distribution

............

90°

 

 

 

 

Approvals

...........................

 

 

ETL Listed. Close mesh Fan Guard

 

 

 

 

 

 

meets OSHA requirements.

 

 

 

 

 

 

 

 

 

 

 

 

MODEL

 

4C630P/9012P

4C631Q/9016Q

 

 

SPEED

 

HIGH

 

MED

 

LOW

HIGH

MED

 

LOW

 

CFM

 

940

 

800

 

700

1510

1380

 

1190

 

 

 

 

 

 

 

 

 

 

 

 

 

M3/s

 

0.44

 

0.38

 

0.33

0.71

0.65

 

0.56

 

RPM

 

1470

 

1320

 

1100

1411

1280

 

1110

 

Amps

 

0.46

 

0.37

 

0.32

0.80

0.57

 

0.47

 

Watts

 

51

 

44

 

39

87

70

 

57

 

 

 

 

 

 

 

 

 

 

 

 

 

dBA

 

45

 

41

 

36

51

47

 

42

GENERAL SAFETY INFORMATION

When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock and injury to person, including the following:

1.Read all instructions before using Fan.

2.Make certain that the power source conforms to the electrical requirements of the Fan.

3.Use this Fan only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electrical shock, or injury to persons.

4.Unplug power cord before installing, servicing, or moving the Fan.

WARNING: DO NOT DEPEND UPON THE ON-OFF SWITCH AS THE SOLE MEANS OF DISCONNECTING POWER WHEN INSTALLING OR SERVICING THE FAN. ALWAYS UNPLUG THE POWER CORD.

5.This Fan must NOT be used in potentially dangerous locations such as flammable, explosive, chemical-laden or wet atmospheres.

6.DO NOT use Fan in or near a window. Rain may create an electrical hazard.

7.The power cord is equipped with a three-prong grounded plug that must be inserted into a matching receptacle. Under no circumstances should the grounding prong be cut off the plug. Where a two-prong wall receptacle is encountered, it must be replaced with a properly grounded three-prong re- ceptacle installed in accordance with the National Electrical Code (NEC) and all applicable local codes and ordinances.

This work must be done only by a qualified electrician, using copper wire only.

WARNING: USE OF A THREE-PRONG TO TWO-PRONG ADAPTER IS NOT RECOMMENDED. IMPROPER CONNECTION MAY CRE- ATE THE RISK OF ELECTRIC SHOCK. USE OF SUCH ADAPTERS IS NOT PERMITTED IN CANADA.

WARNING: This plug is a safety feature. To reduce the risk of fire, electric shock and personal injury, do not remove, replace, repair or tamper with the originally supplied plug. If the Fan does not function properly, it may be due to the safety device incorporated in this plug.

8.Where possible, avoid the use of extension cords. If they must be used, minimize the risk of overheating by ensuring that they are UL listed. Never use a single extension cord to operate more than one Fan.

9.NEVER operate any Fan with a damaged cord or plug or after the Fan malfunctions, has been dropped or damaged in any manner.

10.Do not insert or allow fingers or foreign objects to enter any ventilation or exhaust opening as it may cause an electric shock or fire, or damage the Fan. Do not block or tamper with the Fan in any manner while it is in operation.

11.Always place the Fan on a stable, flat, level surface when operating, to avoid the chance of the Fan overturning. Locate the Power Cord so the Fan or other objects are not resting on it. Do not run Power Cord under carpeting. Do not cover Power Cord with throw rugs, runners, or the like. Arrange Power Cord away from room traffic and where it will not be tripped over.

12.This Fan is not intended for use in wet or damp locations. Never locate a Fan where it may fall into a bathtub or other water container.

13.Do not use Fan outdoors.

14.This Fan is not suitable for use in agricultural facilities including areas where livestock, poultry or other animals are confined. Please refer to National Electric Code (NEC) Article 547-7 (2008), or applicable state or local codes or standards relating to electrical requirements for Agricultural Buildings. THIS FAN

DOES NOT MEET THE REQUIREMENTS OF NEC ARTICLE 547-7 (2008).

15.This Fan is not suitable for use in hazardous locations. Please refer to National Electric Code (NEC) Article 500 or applicable state or local codes or standards relating to electrical requirements for Hazardous locations. THIS FAN DOES NOT

MEET THE REQUIREMENTS OF NEC ARTICLE 500 (2008).

WARNING: REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK – DO NOT USE THIS FAN WITH ANY SOLID STATE SPEED CONTROL DEVICES.

SAVE THESE INSTRUCTIONS

Rev. G 9/09

8

2084077

Rev. G 9/09

1

2084077

Image 1
Contents General Safety Information SpecificationsDescription Does not Meet the Requirements of NEC Article 547-7Maintenance InstallationGarantía Limitada Descripción Conserve Estas IntruccionesInformación General DE Seguridad Instalación Limited WarrantyFuncionamiento Mantenimiento

4C630P/9012P specifications

The Air King 4C630P/9012P is a standout model in the realm of ventilation solutions, designed to offer superior performance and versatility in various settings. This fan model is particularly appreciated for its robust construction and effective airflow capabilities, making it a reliable choice for both commercial and residential applications.

One of the main features of the Air King 4C630P/9012P is its powerful motor. Equipped with a high-efficiency motor, the fan is able to deliver a strong airflow while maintaining energy efficiency. This is crucial in ensuring that spaces remain comfortable without incurring high electricity bills. The motor is also designed for quiet operation, reducing noise disturbances in workspaces or living environments.

The fan features a versatile design that enables it to be mounted in various orientations. This flexibility allows it to be used in multiple applications, whether it's for cooling in a workshop or improving air circulation in a larger room. The sleek design and compact footprint ensure that it fits seamlessly into different spaces without being obtrusive.

Another significant characteristic of the Air King 4C630P/9012P is its durable construction. The unit is made from high-quality materials that withstand the rigors of daily use. Its corrosion-resistant finish ensures longevity, even in demanding environments, such as commercial kitchens or warehouses where moisture and other elements may pose a threat to regular fans.

The fan also incorporates advanced technology for ease of use. For instance, it features user-friendly controls which allow for easy adjustment of speed settings. This level of customization ensures that users can create the ideal airflow conditions for any situation, whether they need a gentle breeze or a more powerful blast of air.

Safety is another priority of the Air King 4C630P/9012P. It is designed with protective grilles and other safety features that prevent accidental contact with moving parts. This makes it a safer choice for workplaces, especially where children or pets may be present.

Overall, the Air King 4C630P/9012P stands out due to its powerful performance, versatility, and durability. It is a fitting solution for anyone seeking an effective and reliable ventilation option that delivers in various environments. With its blend of features and safety considerations, it's a smart investment for those prioritizing quality air circulation.