Rheem Gas Hot Water Supply Heaters Recovery Capacities, General Flow and Piping Specifications

Page 5

RECOVERY CAPACITIES

MODEL NUMBER

STYLE

INPUT BTU/Hr.

 

TEMPERATURE RISE – DEGREES F – GALLONS PER HOUR

 

wo/Pump

w/Pump

Indoor

Outdoor

NATURAL

40°

50°

60°

70°

80°

90°

100°

110°

120°

130°

140°

GBB136

GBBP136

*

*

136,000

330

264

220

188

165

147

132

120

110

101

94

GBC186

GBCP186

*

*

181,000

440

352

293

251

220

195

176

160

147

135

126

GBC264

GBCP264

*

*

264,000

640

512

427

366

320

284

256

233

213

197

183

GBC331

GBCP331

*

*

334,000

811

649

541

463

406

360

324

295

270

250

232

GBC399

GBCP399

*

*

399,000

967

774

645

553

484

430

387

352

322

298

276

GBC512

GBCP512

*

*

511,500

1240

992

827

709

620

551

496

451

413

382

354

GBC627

GBCP627

*

*

627,000

1520

1216

1013

869

760

676

608

553

507

468

434

GBC726

GBCP726

*

*

726,000

1760

1408

1173

1006

880

782

704

640

587

542

503

GBC825

GBCP825

*

*

825,000

2000

1600

1333

1143

1000

889

800

727

667

615

571

GBC926

GBCP926

 

*

926,000

2245

1796

1497

1283

1122

998

898

816

748

691

641

GBC962

GBCP962

*

 

961,700

2331

1865

1554

1332

1166

1036

933

848

777

717

665

GBC1083

GBCP1083

 

*

1,083,000

2625

2100

1750

1500

1313

1167

1050

955

875

808

750

GBC1125

GBCP1125

*

 

1,124,700

2727

2181

1818

1558

1363

1212

1091

991

909

839

779

GBC1178

GBCP1178

 

*

1,178,000

2856

2285

1904

1632

1428

1269

1142

1038

952

879

816

GBC1223

GBCP1223

*

 

1,222,500

2964

2371

1976

1694

1482

1317

1185

1078

988

912

847

GBC1287

GBCP1287

 

*

1,287,000

3120

2496

2080

1783

1560

1387

1248

1135

1040

960

891

GBC1337

GBCP1337

*

 

1,336,600

3240

2592

2160

1852

1620

1440

1296

1178

1080

997

926

GBC1413

GBCP1413

 

*

1,413,000

3425

2740

2284

1957

1713

1522

1370

1246

1142

1054

979

GBC1467

GBCP1467

*

 

1,467,000

3556

2845

2371

2032

1778

1581

1423

1293

1185

1094

1016

GBC1570

GBCP1570

 

*

1,570,000

3806

3045

2537

2175

1903

1692

1522

1384

1269

1171

1087

GBC1630

GBCP1630

*

 

1,630,000

3952

3161

2634

2258

1976

1756

1581

1437

1317

1216

1129

GBC1758

GBCP1758

 

*

1,758,000

4262

3409

2841

2435

2131

1894

1705

1550

1421

1311

1218

GBC1826

GBCP1826

*

 

1,825,600

4426

3541

2950

2529

2213

1967

1770

1609

1475

1362

1264

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GENERAL FLOW AND PIPING SPECIFICATIONS

 

 

 

 

 

 

 

 

 

Water Hardness

 

 

 

 

 

 

MODELS

 

 

SOFT

 

 

 

 

 

MEDIUM

 

 

 

 

HARD

 

 

 

 

 

0-4 Grains Per Gallon

 

 

5-15 Grains Per Gallon

 

16 & Over Grains Per Gallon

Indoor

Outdoor

T

GPM

P

MPS

 

SHL

T

GPM

 

P

 

MPS

SHL

T

GPM

P

MPS

SHL

136

136

22

10

3.4

1-1/4

 

5.09

17

13

 

5.5

 

1-1/4

8.2

10

22

14.7

1-1/4

22

186

186

15

20

1.82

1-1/2

 

4.48

11

26

 

3

 

1-1/2

7.5

7

40

6.8

1-1/2

17

264

264

21

20

1.85

1-1/2

 

4.51

16

26

 

3.1

 

1-1/2

7.6

10

42

8.3

1-1/2

18.8

331

331

27

20

1.9

1-1/2

 

4.56

20

26

 

3.2

 

1-1/2

7.7

13

42

8.5

1-1/2

19

399

399

30

22

2.1

1-1/2

 

5.08

25

26

 

3.3

 

1-1/2

7.8

15

43

9

1-1/2

19.5

512

512

20

42

1.8

2

 

4.4

16

52

 

2.9

 

2

7

10

84

6.8

2

16.6

627

627

25

41

1.9

2

 

4.5

19

54

 

3.1

 

2

7.2

11

90

8.5

2

20.4

726

726

29

41

2

2

 

4.6

20

60

 

4

 

2

9.3

13

90

9

2

20.8

825

825

30

45

2.5

2

 

5.7

20

68

 

5.2

 

2

11.7

15

90

9.3

2

21.1

962

926

30

53

3.5

2-1/2

 

4.9

20

79

 

7.5

 

2-1/2

10.5

17

90

10.1

2-1/2

14.3

1125

1083

30

61

5.5

2-1/2

 

7.5

20

90

 

11.8

 

2-1/2

16

20

90

11.8

2-1/2

16

1223

1178

30

67

6.5

2-1/2

 

8.8

22

90

 

12

 

2-1/2

16.2

22

90

12

2-1/2

16.2

1337

1287

30

73

8.4

2-1/2

 

11

24

90

 

13.3

 

2-1/2

17.5

24

90

13.3

2-1/2

17.5

1467

1413

30

80

10.8

2-1/2

 

14.1

26

90

 

13.8

 

2-1/2

18

26

90

13.8

2-1/2

18

1630

1570

30

89

13.7

2-1/2

 

17.6

29

90

 

14.8

 

2-1/2

19

29

90

14.8

2-1/2

19

1826

1758

32

90

15.5

2-1/2

 

19.7

32

90

 

15.5

 

2-1/2

19.7

32

90

15.5

2-1/2

19.7

NOTE: Additional pipe fittings will increase the system head loss. Select a pump based on the water hardness, flow and system head loss. If water heater is more than two stories above the tank, consult the pump manufacturer.

T

– Temperature Rise, Degree F @ GPM Flow

GPM

– Gallons per Minute Flow

P

– Pressure Drop, Ft. thru Heat Exchanger

MPS

Minimum Pipe Size, NPT

SHL

System Head Loss

 

 

 

Sizing based on water heater and tank being placed 5 feet apart. The equivalent length of pipe valves and fittings in the system is as follows.

1-1/4" NPT = 65 Ft (136)

1-1/2" NPT = 70 Ft (186-399)

2" NPT = 75 Ft (512-825)

2-1/2" NPT = 80 Ft (926-1826)

Image 5
Contents Certifications and Ratings Construction FeaturesAvailable in Indoor and Outdoor Models Flexibility ReliabilityEfficiency Asme Example SystemModel Number Style Specifications and DimensionsGeneral Flow and Piping Specifications Recovery CapacitiesModel Number Style ModelsGas Hot Water Supply Heaters