Desa FB-5B, FBS-3C Fresh AIR for Combustion and Ventilation, Producing Adequate Ventilation

Page 4

INFRARED PROPANE/LP GAS HEATER

FRESH AIR FOR COMBUSTION AND VENTILATION

WARNING: This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ven- tilation air. Read the following in- structions to insure proper fresh air for this and other fuel-burning appliances in your home.

Today’s homes are built more energy effi- cient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.

While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper com- bustion and ventilation.

Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide ad- equate fresh air for these appliances. This will insure proper venting of vented fuel- burning appliances.

PRODUCING ADEQUATE VENTILATION

The following are excerpts from National Fuel Gas Code, NFPA 54/ANS Z223.1, Sec- tion 5.3, Air for Combustion and Ventilation.

All spaces in homes fall into one of the three following ventilation classifications:

1.Unusually Tight Construction

2.Unconfined Space

3.Confined Space

The information on pages 4 through 6 will help you classify your space and provide adequate ventilation.

Unusually Tight Construction

The air that leaks around doors and win- dows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.

Unusually tight construction is de- fined as construction where:

a.walls and ceilings exposed to the outside atmosphere have a con- tinuous water vapor retarder with a rating of one perm (6 x 10-11kg per pa-sec-m2) or less with open- ings gasketed or sealed and

b.weather stripping has been added on openable windows and doors and

c.caulking or sealants are applied to areas such as joints around window and door frames, be- tween sole plates and floors, be- tween wall-ceiling joints, be- tween wall panels, at penetra- tions for plumbing, electrical, and gas lines, and at other openings.

If your home meets all of the three criteria above, you must provide ad- ditional fresh air. See Ventilation Air From Outdoors, page 6.

If your home does not meet all of the three criteria above, see Determining Fresh-Air Flow for Heater Location, page 5.

Confined and Unconfined Space

The National Fuel Gas Code ANS Z223.1 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggre- gate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are con- sidered a part of the unconfined space.

This heater shall not be installed in a con- fined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air.

*Adjoining rooms are communicating only if there are doorless passageways or ventila- tion grills between them.

4

107297

Image 4
Contents Infrared VENT-FREE PROPANE/LP GAS Heater What to do if YOU Smell GASSafety Information Infrared PROPANE/LP GAS HeaterProduct Features Product IdentificationLocal Codes UnpackingFresh AIR for Combustion and Ventilation Producing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location Fresh AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Installation ItemsInstalling Thermostat Sensing Bulb Check GAS TypeInstalling Heater to Wall Mounting BracketMethods For Attaching Mounting Bracket To Wall Marking Screw LocationsAttaching Mounting Bracket To Wall Installing Bottom Mounting ScrewsPlacing Heater On Mounting Bracket Connecting to GAS Supply Typical Inlet Pipe DiametersFor Your Safety OperatingHeater Checking GAS ConnectionsManual Lighting Procedure Operating HeaterLighting Instructions To Select Heating LevelFor Your Safety Read Before Lighting Press in control knob and turn counCleaning and Maintenance Inspecting BurnerTroubleshooting Observed Problem Possible Cause RemedyInfrared PROPANE/LP GAS Heater Top Specifications Parts CentralsReplacement Parts Service HintsService Publications Accessories Technical ServiceIllustrated Parts Breakdown ODS/Pilot Assembly Burner AssemblyFB-3B Parts List KEY FB-3B DescriptionBurner Assembly ODS/Pilot Assembly FB-5BKEY FB-5B Description FBS-3C KEY FBS-3B Description QTY FBS-5B FBS-5C KEY FBS-5B Description QTYWarranty Information International

FBS-3C, FB-5B, FBS-5C specifications

Desa FBS-5C, FB-5B, and FBS-3C represent an innovative line of advanced heating solutions that prioritize energy efficiency, user comfort, and environmental sustainability. These models showcase cutting-edge technology and an array of features designed to meet the diverse needs of residential and commercial spaces.

The Desa FBS-5C distinguishes itself with its high efficiency rating and sleek design. This model incorporates a robust heat exchanger that maximizes thermal efficiency, ensuring that energy consumption is minimized while delivering consistent warmth. The advanced digital thermostat allows users to set precise temperatures, while the programmable timing function enables enhanced control over heating schedules. Safety is paramount, and the FBS-5C features multiple safety mechanisms, including over-temperature protection and tip-over shutoff.

The FB-5B model is tailored for users seeking an effective heating solution without compromising on design. This model is compact and lightweight, making it ideal for smaller spaces or discrete installation. It incorporates advanced radiant heating technology that creates a comfortable warmth without the need for traditional forced air systems. Additionally, the FB-5B is equipped with a user-friendly control panel, allowing for easy adjustments and settings. Its low noise operation is particularly beneficial for environments where silence is essential, such as bedrooms or offices.

The FBS-3C model takes innovation a step further by integrating smart technology into its operating system. This model is Wi-Fi enabled, allowing users to control their heating remotely via smartphone applications. The adaptability of the FBS-3C ensures that it can seamlessly integrate with smart home systems, providing a convenient and user-friendly experience. Energy monitoring features enable users to track consumption and adjust settings to optimize efficiency, ultimately reducing heating costs and environmental impact.

In conclusion, Desa's FBS-5C, FB-5B, and FBS-3C models offer a range of features that cater to different heating needs. With their focus on efficiency, safety, and smart technology, these models exemplify the future of heating solutions. Whether for a cozy home setting or a commercial application, Desa's innovative approaches ensure warmth and comfort while promoting sustainability and user convenience.