Model PH-100

Main Specification

<INPUT>

INPUT (L, R) (Balanced)

 

• Connector

: XLR-3-31 type (x 2)

 

: PHONE (x 2)

• Standard input level

: +4dBu (XLR-3-31 type)

 

: -10dBV (PHONE)

• Input Impedance

: 10kΩ or more

INPUT (L/MONO, R) (Unbalanced)

• Connector

: RCA pin (x 2)

• Standard input level

: -10dBV

• Input Impedance

: 10kΩ or more

AUX IN (L/MONO, R) (Unbalanced)

• Connector

: RCA pin (x 2)

• Standard input level

: -10dBV

• Input Impedance

: 10kΩ or more

CHANNEL IN (1~10) (Unbalanced)

• Connector

: RCA pin (x 10)

• Standard input level

: -10dBV

• Input Impedance

: 10kΩ or more

<OUTPUT>

PHONES OUT (1~10)

Available on both the front and rear panels (the front jacks take priority.)

• Connector

: PHONE (x 20)

• Maximum Output level : 500mW

• Load impedance

: 8 ~ 32Ω

• Frequency Response

: 30Hz ~ 20kHz +/-1dB

• Noise

: -65dBV or less

• Distortion

: 0.3% or less

CASCADE OUT (L, R)

 

• Connector

: RCA pin (x 2)

• Output level

: -10dBV

• Frequency Response

: 30Hz ~ 20kHz +/-1dB

• Noise

: -80dBV or less

• Distortion

: 0.1% or less

<GENERAL>

• Dimensions

: 482 (W) x 49 (H) x 267 (D)

• Weight

: Approx. 4kg

• Power supply

: 120VAC 60Hz

:230V ~ 50/60Hz

Power consumption : Approx. 18W

* Specifications and appearance are subject to change without notice for product improvement.

Block diagram

INPUT L

BALANCE IN

INPUT R

L/MONO

UNBAL IN

R

L/MONO

AUX IN

R

1

2

3

4

5

CHANNEL IN

6

7

8

9

10

INPUT

ST/MONO

AUX IN

PEAK

OUTPUT LEVEL 1

FRONT

 

PHONES 1

 

REAR

OUTPUT LEVEL 2

FRONT

 

PHONES 2

 

REAR

OUTPUT LEVEL 3

FRONT

 

 

PHONES 3

 

REAR

OUTPUT LEVEL 4

FRONT

 

PHONES 4

 

REAR

OUTPUT LEVEL 5

FRONT

 

PHONES 5

 

REAR

OUTPUT LEVEL 6

FRONT

 

PHONES 6

 

REAR

OUTPUT LEVEL 7

FRONT

 

PHONES 7

 

REAR

OUTPUT LEVEL 8

FRONT

 

PHONES 8

 

REAR

OUTPUT LEVEL 9

FRONT

 

PHONES 9

 

REAR

OUTPUT LEVEL 10

FRONT

 

PHONES 10

 

REAR

 

L

 

CASCADE OUT

 

R

7

Image 7
Contents 2 2 2 ContentsIntroduction Safety Instructions Front Panel section Names and FunctionsRear Panel section Example 2 Using an individual talkback monitor facility Example 1 Using the PH-100 as a cue boxApplication Examples Second unit Example -3 Cascading PH-100External device First unitPhones OUT 1~10 Main SpecificationCascade OUT L, R Affect of Immunity on This Equipment