AquaStar manual Appliance details, GWH 1600 P specifications Technical data, Water resistant

Page 3

Appliance details

2Appliance details

2.1GWH 1600 P specifications (Technical data)

Approved in US/Canada

Capacity

GWH 1600 P: 4.3 GPM

Maximum output

GWH 1600 P: 91 525 Btu/hr

Maximum input

GWH 1600 P: 117 000 Btu/hr

Efficiency in %

Recovery efficiency 78%

Min. Output

GWH 1600 P: 23 906 Btu/hr

Gas Requirement

Gas connection (inches) - ¾” NPT

Inlet gas pressure under maximum operation* Propane: 10.5” - 14” water column Natural Gas: 5.7” - 14” water column.

*To measure Gas Pressure, see Measuring Gas Pressure, chapter 3.8.

Venting Natural Draft

Vent diameter (inches) - 5”

Minimum height (feet) - 6’ with no elbows Vertical termination

Sidewall termination only with AQ4 power vent kit.

Water

Hot water connection (inches) - ½” NPT Cold water connection (inches) - ½” NPT

Water valve material: Polymer (PPS) (Polypropylene Sulfid)

Minimum water flow: 0.5 gallon/minute (1.9 l/m)

Minimum recommended water pressure: 30 PSI (2.07 bar)

Connections:

– Bottom of heater

Dimensions

Depth (in): 8.66” (220 mm)

Width (in): 18.11” (460 mm)

Height (in): 25.79” (655 mm)

Weight: 35 pounds (16 kg).

Gas types

Natural Gas.

LP Gas

Safety devices

Flame failure device (ionization thermocouple) Pressure relief valve (supplied with heater) Over heat prevention (temperature limiter).

Water resistant

IP X4.

6 720 608 030

3

Image 3
Contents Model GWH 1600 P Index IndexWater resistant GWH 1600 P specifications Technical dataAppliance details Appliance detailsGeneral rules to follow for safe operation Unpacking the GWH 1600 P heaterDimensions in Inches and mm Dimensions and installation clearancesInstallation instructions Installation instructionsProper location for installing your heater Heater placement and clearancesRemove cover and inspect Remove the temperature control Mounting HeaterHang heater on two L shaped hooks. See Fig Appliances located in confined spaces Combustion air requirementsVenting Existing interior masonry chimney Installation instructions Masonry chimneyGAS Connections Gas piping & connectionsFor Natural GAS Water connections Connecting manometer Shut off gasConnecting the pressure relief valve PRV Measuring gas pressureOperation instructions For your safety read before operating your water heaterOperation instructions Recirculation applicationSetting the water temperature Lighting instructionsTo turn off appliance Draining water from heater Temperature adjustment knobPilot Maintenance and serviceMaintenance intervals Water valveOperate the circulating pump Vent assemblyMain burners Mineral scale build-upPilot goes out during or after hot water use TroubleshootingPilot lights, but goes out when button released Introduction Pilot does not lightHot water temperature fluctuates at tap Burners do not light with water flowCheck for a clogged inlet water filter screen see chapter Burners ignite without hot water flow Noise when heater is runningWater is too hot Water is not hot enoughBurners do not operate cleanly yellow flames when operating Protecting the environment Protecting the environmentSaving water resources Interior components and diagram parts list Interior components and diagram parts listInterior components Components Diagram Components diagramDescription Reference Parts listTwelve Year Limited Warranty Serial Number Gas Pressure Reading StaticWaitsfield, VT all rights reserved