Bradford-White Corp 238-44422-00G instruction manual Maintenance

Page 17

Maintenance continued-

3.At least once a year, check the combination temperature and pressure relief valve to insure that the valve has not become encrusted with lime. Lift the lever at the top of the temperature-pressure relief valve several times until the valve seats properly without leaking and operates freely.

WARNING

When lifting lever of temperature-pressure relief valve, hot water will be released under pressure. Be certain that any released water does not result in bodily injury or property damage.

4.If the combination temperature and pressure relief valve on the appliance discharges periodically, this may be due to thermal expansion in a closed water supply system. Contact the water supplier or local plumbing inspector on how to correct this situation. Do not plug the combination temperature and pressure relief valve outlet for any reason.

5.Monthly, drain off a gallon of water from the water heater to remove silt and sediment.

WARNING! THIS WATER MAY BE HOT.

6.A combination sacrificial anode rod/hot water outlet nipple has been installed to extend tank life. The anode rod should be inspected periodically (every 2 years) and replaced when necessary to prolong tank life. Water conditions in your area will influence the time interval for inspection and replacement of the anode rod. Contact the plumbing professional who installed the water heater or the manufacturer listed on the rating plate for anode replacement information. The use of a water softener may increase the speed of anode consumption. More frequent inspection of the anode is needed when using softened (or phosphate treated) water.

CAUTION

FOR YOUR SAFETY, DO NOT ATTEMPT TO REPAIR THERMOSTAT(S), HEATING ELEMENTS, OR ELECTRICAL WIRING. REFER SUCH REPAIRS TO A QUALIFIED SERVICE TECHNICIAN.

17

Image 17
Contents Installation & Operating Table of Contents General Information Locating The Water Heater InstallationLocating The Water Heater Water Connections Water Connections Water Connections Water Connections Upright Models See Figure Utility Models See Figure Water Connections Electrical Connections To Fill the Water Heater General OperationThermostat Adjustment Maintenance Maintenance Maintenance