Bock Water heaters 80SK 30, 40 & 50SK, 80 & 119SK, 114 @ 57,000, 165 @ 84,000, 172 @ 84,000

Page 2

SideKick

 

Anode Rod

 

 

 

Hot Outlet,

Hot Outlet/

Cold Inlet,

1-1/2" NPT

 

Anode Rod,

3/4" NPT

 

3/4" NPT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Anode

 

Anode Rod

 

 

 

 

 

 

 

 

 

 

 

 

Rod

 

 

 

 

 

 

 

 

 

 

T&P Relief Valve

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T&P Relief Valve

 

 

 

 

 

 

 

From Boiler, 1" NPT

 

 

 

 

 

 

 

 

Aquastat

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

From Boiler,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

1" NPT

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

To Boiler,

 

 

 

 

 

 

B

 

 

 

 

 

 

 

1" NPT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

G

 

 

 

 

 

 

 

Aquastat

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F

 

 

 

 

 

Drain Valve

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Drain Valve

 

 

 

 

 

 

 

 

 

 

D

 

 

 

A

 

 

 

 

 

 

 

To Boiler,

 

 

 

 

30, 40 & 50SK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1"NPT

 

 

 

 

 

 

 

Dimensions

 

 

 

Shipping

E

 

 

 

Model

 

 

 

 

 

 

 

 

Weight

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F

 

 

A

B

 

C

 

D

E

F

G

H

(lbs)

 

 

 

 

 

 

 

 

 

 

30SK

22”

35 3/4”

27 3/4”

19 1/2”

11 3/4”

6 1/2”

4 1/2”

N/A

180

H

A

G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40SK

22”

42 3/4”

34 3/4”

31 1/2”

16 3/4”

6 1/2”

4 1/2”

N/A

226

 

80 & 119SK

 

50SK

22”

48 3/4”

39 3/4”

31 1/2”

16 3/4”

6 1/2”

4 1/2”

N/A

231

Cold Inlet, 1" NPT

 

 

80SK

24”

64 3/4”

57 1/8”

 

33”

19 1/4”

8”

5”

5”

297

 

 

 

 

119SK

28”

65 1/4”

57 3/4”

33 3/4”

16 1/4”

8 3/4”

5”

6 1/2”

397

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIRST HOUR RATING (gal) @ Coil Output (Btu/hr)

 

 

Actual Tank

 

First Draw

Heat Source

 

180° F

180° F

180° F

200° F

200° F

200° F

Model

 

Friction Loss*

 

Volume (gal)

 

(gal)

 

 

8 GPM**

10 GPM**

12 GPM**

8 GPM**

10 GPM**

12 GPM**

 

 

 

 

(ft. w.c.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30SK

 

30

 

25

 

 

2

110 @ 55,000

114 @ 57,000

117 @ 59,000

132 @ 69,000

136 @ 71,000

139 @ 73,000

40SK

 

38

 

33

 

 

3

153 @ 77,000

165 @ 84,000

177 @ 92,000

183 @ 96,000

195 @ 104,000

207 @ 111,000

50SK

 

45

 

40

 

 

3

160 @ 77,000

172 @ 84,000

184 @ 92,000

190 @ 96,000

202 @ 104,000

214 @ 111,000

80SK

 

75

 

70

 

 

5

200 @ 83,000

212 @ 91,000

224 @ 98,000

233 @ 104,000

245 @ 112,000

257 @ 119,000

119SK

 

110

 

102

 

 

5

232 @ 83,000

244 @ 91,000

256 @ 98,000

265 @ 104,000

277 @ 112,000

289 @ 119,000

All data obtained through testing in accordance with GAMA INDIRECT-FIRED WATER HEATER TESTING STANDARD IWH-TS-1_MARCH 2003

*At 8 GPM

**Coil Input (temperature, flow rate). Ratings based on 77°F rise with 58°F inlet potable water. Note: First Hour Rating = First Draw + Continuous Draw

Warning: Installation should be in accordance with all national and/or local codes. In the absence of local codes, refer to NFPA 54 or ANSI Z.21.10.1.

Caution: The recommended maximum hot water termperature setting for normal residential use is 120°F. Bock recommends a tempering valve or anti-scald valve be installed and used according to the manufacturer’s directions to prevent scalding.

Pressures (all): Working pressure, 150 psi; testing pressure, 300 psi

Standard Voltage (all): 120V, 60 Hz, 1P

www.bockwaterheaters.com

110 South Dickinson Street , Madison, Wisconsin 53703

Toll Free 800.794.2491 Phone 608.257.2225 Fax 608.257.5304

80021 Rev 11/07

Image 2
Contents Indirect Water Heater Accessible, tamper-proofSideKick Listed and Asme rated114 @ 57,000 30, 40 & 50SK80 & 119SK 165 @ 84,000