Bosch Appliances 125HX LP Features, Unpacking the Aquastar Heater, Principle of Operation

Page 2

Principle of Operation:

When a hot water faucet is opened, the water flow through the heater causes the gas valve to open. At the same time the hydro-generator activates the electronics which sends a spark to the pilot. The flame sensor confirms the pilot has been lighted and allows the first two burners to come on. The flame sensor confirms correct activation and all burners come on. The pilot goes off. The heat exchanger coils absorb the heat generated by the burners and transfer heat to the water. When the hot water faucet is shut off, the gas valve automatically closes and the burners turn off. Your hot water faucet is an ignition key to activate the water heater, giving you control over your hot water energy use. Every time you turn off your hot water faucet, the energy consumption of your hot water returns to zero.

FEATURES

-Electronic Pilot Ignition driven by hydro-generator

-High Quality Materials for Long Working Life.

-Copper heating coils for endless supply of hot water.

-Burner output proportional to hot water flow demand for maximum energy efficiency.

-Safety flame sensor at pilot burner.

-Automatic overheating protection shut-off sensor.

-Temperature limiter.

-Flue gas safety device.

-Stainless steel burners with stabilized blue flame.

-Built-in corrosion resistant draft inducer.

-Compact space saver: mounts on a wall with two hooks.

-Easily removable one-piece cover.

-Easy one person installation.

-Adjustable water flow restrictor to ensure that water flow demand will not exceed the heating capacity of the heater.

-On/Off Switch to activate system.

-Red LED indicator flashes with low water pressure.

-Green LED indicator main burner condition.

BOSCH is constantly improving our products, therefore specifications are subject to change without prior notice.

AquaStar 125HX LP and 125HX NG Specifications

Gas Input max.: 117,000 Btu/hr min.: 28,000 Btu/hr

Water Connection ½” Thread fitting NPT

H x W x D 29 3/4” x 18 1/4” x 8 3/4"

Vent 5”

Gas Connection 1/2” NPT thread

Min. Water Pressure 18 Psi at 4 GPM

Max. Water Pressure 150 Psi

Shipping Weight 43 LB

Net Weight 40 LB

1.8GPM at 90° rise

3.7GPM at 45° rise

Min. Water Flow 1/2 gal/min

LP GAS Supply Pressure

(before Aquastar regulator) min. 11” W.C. max. 14” W.C.*

Required LP GAS Pressure at inlet

tap while Aquastar is operating: 10.5” W.C.

LP GAS Burner Manifold pressure while Aquastar is

operating at maximum input:

9.0” W.C.

Natural Gas Supply Pressure

(before Aquastar regulator) min.: 7” W.C. max.: 14” W.C.*

Required Natural Gas Pressure at inlet tap while Aquastar is operating: 5.7” W.C.

Natural Gas Burner Manifold Pressure while Aquastar is

operating at maximum input:

4.2” W.C.

*Inlet gas pressure before Aquastar regulator must not exceed this value. Pressure may need to be adjusted for high altitudes, see page 7.

UNPACKING THE AQUASTAR HEATER

This heater is packed securely. The box includes two water connection fittings, a control knob, a gas pressure regulator, a pressure relief valve, an incandescent particle tray, two hooks for hanging the heater, this manual, a personal letter, a warranty statement and a warranty registration card. Do not lose this manual, as there is a charge for replacement. Please complete and return the enclosed warranty registration card.

2

6 720 606 562 (02.03)

Image 2
Contents What to do if YOU Smell GAS For Your SafetyTable of Contents Unpacking the Aquastar Heater FeaturesAquaStar 125HX LP and 125HX NG Specifications Principle of OperationAquastar Model 125HX General Rules to Follow For Safe Operation Proper Location for Installing Your HeaterWhere IT could Freeze Clearances Mounting InstallationCombustion AIR Requirements Venting To check the draftAltitude Natural Gas Liquid Propane Maximum Inlet GAS Flow Pressure SettingGAS Line Sizing GAS Line Sizing For Natural GAS For LP GASOperating Instructions For Your Safety Read Before Operating Your HOT Water HeaterWater Connections To Turn OFF GAS to Appliance Setting the Water TemperatureLighting and Operating Instructions OffReview Maintenance Table on the Back of this Manual Maintenance and ServiceTrouble Shooting IntroductionNo Spark AT the Pilot Water is TOO HOT Pilot Lights but Burners will not Come onMain Burners GO OUT During HOT Water USE Water is not HOT EnoughGas pressure is too low HOT Water Temperature FluctuatesUnbalanced pressure in waterlines 720 606 562 Interior Components Diagram and Parts List Interior Components Diagram Parts List 125HX Installation Checklist GAS Line Size Controlled Energy Corp

125HX LP specifications

The Bosch Appliances 125HX LP is an outstanding addition to any modern kitchen, exemplifying innovation and efficiency in kitchen technology. Renowned for their commitment to quality and performance, Bosch has crafted this model to meet the needs of both amateur and professional chefs.

One of the standout features of the 125HX LP is its powerful cooking capabilities. The model is equipped with a high-efficiency burner that provides intense heat for rapid cooking and precise temperature control. This is particularly beneficial when searing meats or preparing gourmet dishes, allowing users to achieve professional-grade results at home.

Another significant characteristic of the 125HX LP is its sleek and durable design. Constructed with premium materials, this appliance not only enhances the aesthetic appeal of your kitchen but also promises longevity. The stainless steel finish is not only attractive but also easy to clean, ensuring that the appliance maintains its polished look over time.

In terms of user-friendly technology, Bosch has integrated advanced features such as an intuitive control panel. This panel provides clear visibility and ease of access to various cooking settings while offering precise temperature adjustments. The 125HX LP also includes an automatic ignition system, which ensures that lighting the burners is both quick and safe, reducing the risk of accidents.

Safety is a major consideration in the design of the 125HX LP. The appliance features flame failure detection which automatically shuts off the gas supply if the flame goes out, providing peace of mind during use. Additionally, the cooking surface is designed to minimize the risk of burns, making it ideal for families.

The Bosch Appliances 125HX LP stands out with its commitment to energy efficiency. The model is designed to reduce energy consumption without compromising performance, making it an eco-friendly choice for the environmentally conscious consumer.

In summary, the Bosch Appliances 125HX LP combines power, design, and safety features to deliver a superior cooking experience. With its advanced technology and user-oriented features, this model is perfect for those who prioritize functionality and style in their kitchen appliances. Whether a casual cook or a culinary enthusiast, the Bosch 125HX LP is sure to meet and exceed expectations and stand the test of time in any kitchen environment.